BUILTRITE BUILDERS | B= | C | 08/27/2015 | inspection was completed at 4:00 pm 8/26/2015 | BOBF | BOBF | | B= | C | 5023601 |
BUILTRITE BUILDERS | B= | P | 08/27/2015 | ballisters are over 4" on side deck / engineer letter for pergola piers on file / final inspection was performed at 4pm 8/26/2015 -- Schedule a new Building Final when above items are complete. | BOBF | BOBF | | B= | P | 5023316 |
BUILTRITE BUILDERS | BSP | P | 08/27/2015 | eng letter for piers on file | BOBF | BOBF | | BSP | P | 5023315 |
BUILTRITE BUILDERS | BSP | P | 08/27/2015 | eng stamped pergola design on file | BOBF | BOBF | | BSP | P | 5023253 |
BUILTRITE BUILDERS | BSP | P | 08/24/2015 | post connection for decks and pergola okay / eng letter for pergola piers on file / design for pergola piers on file | BOBF | BOBF | | BSP | P | 5020899 |
BUILTRITE BUILDERS | BSP | R | 07/21/2015 | provide structural drawing for pergola with pier requirements / need eng letter for deck piers | BOBF | BOBF | | BSP | R | 4997601 |
BUILTRITE BUILDERS | BLA | C | 07/07/2015 | | BOBF | BOBF | | BLA | C | 4988241 |
BUILTRITE BUILDERS | BLA | T | 06/29/2015 | PAID (REC#1272237) lath not stapled (entire) seal exterior penetrations | ED | ED | | BLA | T | 4983120 |
BUILTRITE BUILDERS | BTR | C | 05/21/2015 | | BOBF | BOBF | | BTR | C | 4958941 |
BUILTRITE BUILDERS | BIN | C | 05/07/2015 | | BOBF | BOBF | | BIN | C | 4951096 |
BUILTRITE BUILDERS | BFR | C | 05/04/2015 | | BOBF | BOBF | | BFR | C | 4948464 |
BUILTRITE BUILDERS | BFR | R | 04/29/2015 | narrow wall not nailed per plan / block garage door brackets / fire block ballon walls / missing hangar at xx01 / missing LUS 210 at all porch rafters / expose rear porch posts / missing TBE 6 at M05 / missing ls 30 at all short rafters throughout / block all truss heals greater than 8" / inspection stopped too many items | BOBF | BOBF | | BFR | R | 4945470 |
BUILTRITE BUILDERS | BFI | C | 11/10/2014 | | DALE | DALE | | BFI | C | 4851403 |
BUILTRITE BUILDERS | BFD | C | 11/10/2014 | | DALE | DALE | | BFD | C | 4851402 |
BUILTRITE BUILDERS | BFN | C | 11/10/2014 | ok per eng. / all paperwork on file / float / ufer in per eng. | DALE | DALE | | BFN | C | 4851401 |
BUILTRITE BUILDERS | BFT | C | 11/10/2014 | ok per eng. | DALE | DALE | | BFT | C | 4851400 |
HOMERUN ELECTRONICS, INC. | E= | C | 08/26/2015 | | CRAIG | CRAIG | | E= | C | 5023041 |
HOMERUN ELECTRONICS, INC. | E= | R | 08/25/2015 | label all switches in kitchen -------- install island gfi outlet ------------ no power to outlet in last bedroom walking to mech room by light switch ---------- where is xfmr for puck lights for kitchen sink and down stair -------------- install light for x mas outlets to test for gfi ----------- both a/c' s ok both 30 amp ---------- hot tub pre wire | CRAIG | CRAIG | | E= | R | 5022011 |
HOMERUN ELECTRONICS, INC. | ES | C | 04/24/2015 | Residential Underground: 200 amp 3/w new res seal meter | CRAIG | CRAIG | | ES | C | 4942820 |
HOMERUN ELECTRONICS, INC. | ER | C | 04/24/2015 | nail plate feeder to sub panel on main level ------------- 4/w 4/0 al to sub panel in finished basement 4 - 10/3 1 - 20 3 - 6/3 al 2 - 6/3 cu to steamer / hot tube no central vac | CRAIG | CRAIG | | ER | C | 4942813 |
HOMERUN ELECTRONICS, INC. | EUG | C | 01/02/2015 | 3/w 4/0 al service lateral | CRAIG | CRAIG | | EUG | C | 4879977 |
HOMERUN ELECTRONICS, INC. | EUG | R | 12/23/2014 | backfilled before inspection | MATTHEW | MATTHEW | | EUG | R | 4877198 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | H= | C | 08/26/2015 | Laundry in lower lvl is future only, Permit will be pulled for vent if used later. rest of corrections completed. Final ok. | MARK | MARK | | H= | C | 5022671 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | H= | P | 08/25/2015 | No dryer vent or m/a in lower level laundry, 1- condenser pad needs to be raised min 3" above grade, 2- furn vent terms are plugged w/ stucco, w/h vent connector in contact with copper pipe, remove insulation around b vent in mech rm. Re inspect all. | MARK | MARK | | H= | P | 5021614 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HC | C | 04/24/2015 | RELEASE METER | MARK | MARK | | HC | C | 4942631 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HRR | C | 04/24/2015 | Rough ok. | MARK | MARK | | HRR | C | 4942620 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HRR | P | 04/23/2015 | There is wiring hanging out of a return in basement. Electrician informs me he will be installing an electrical box inside the return. It will require panning to separate it from the return. Rest ok. | MARK | MARK | | HRR | P | 4941544 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HRR | P | 04/22/2015 | Need to seal returns where wiring runs through several locations. Rest ok. Equip matches. Sealed combustion furnaces (2) a/c rough. Fin. bsmnt. | MARK | MARK | | HRR | P | 4940436 |
SPRINGS GAS, INC. | HI | C | 04/14/2015 | 10 lb test is good. | MARK | MARK | | HI | C | 4935525 |
SPRINGS GAS, INC. | HI | P | 04/10/2015 | Low test. Note: 1 1/2" main. Has 2- furn, 2-w/h, 3- f/p, 2- fut bbq, cook top | MARK | MARK | | HI | P | 4933953 |
UNIQUE RADIANT HTG. & PLBG. | P= | C | 08/25/2015 | NOTE : ROUGH ONLT FOR LAUNDRY TUB AND BAR , FINISHED BASEMENT , PVB INSTALLED , POTABLE WATER CERT TO SCANNING | GABE | GABE | | P= | C | 5021516 |
UNIQUE RADIANT HTG. & PLBG. | PTO | C | 04/22/2015 | NEED VALVE AT POT FILLER BY FINAL , NOTE : FINISHED BASEMENT , IRRIGATION STUB | GABE | GABE | | PTO | C | 4940392 |
UNIQUE RADIANT HTG. & PLBG. | PB | C | 12/04/2014 | | TIM | TIM | | PB | C | 4864898 |
BUILTRITE BUILDERS | PWO | C | 11/20/2014 | | TIM | TIM | | PWO | C | 4857215 |