BUILTRITE BUILDERS | B= | C | 05/08/2015 | All other required Final inspections are complete. (This is a computer generated result) | DALE | DALE | | B= | C | 4951144 |
BUILTRITE BUILDERS | B= | P | 05/06/2015 | finished basement, deck in. Additional Inspections Required (computer generated): External Agency Inspection HD= by HEALTHDEPT is not Completed yet. | DALE | DALE | | B= | P | 4950058 |
BUILTRITE BUILDERS | B= | R | 05/05/2015 | need address at street / need insulation at mech. room and no exposed foam. Additional Inspections Required (computer generated): External Agency Inspection HD= by HEALTHDEPT is not Completed yet. | DALE | DALE | | B= | R | 4949582 |
BUILTRITE BUILDERS | BLA | C | 03/19/2015 | | ED | ED | | BLA | C | 4920164 |
BUILTRITE BUILDERS | BIN | P | 03/11/2015 | insulation inspection ok, still need engineer letter for framing | ED | ED | | BIN | P | 4915181 |
BUILTRITE BUILDERS | BFR | P | 03/06/2015 | still need eng. for front porch hanger / ok to insulate | DALE | DALE | | BFR | P | 4913078 |
BUILTRITE BUILDERS | BFR | R | 03/04/2015 | add full weld fillet around steel tube at top, add FHA straps at top plate braks above front door wall, need engineering where 2 ply ridge is not point loaded down to header - as per plan, all note # (92) is not completed, shim misc. trimmers, add FHA straps at top plate gable, and in basement top plates, reinspect ((ALL POINT LOADS IN BASEMENT)), remove all floating wall blocks, cannot use 1x4 for lateral bracing, missing lateral at B1,B7,BG2 trusses -- air barriers at insulation | ED | ED | | BFR | R | 4911375 |
BUILTRITE BUILDERS | BSP | P | 02/04/2015 | porch frame, posts and connections ok | DALE | DALE | | BSP | P | 4896570 |
BUILTRITE BUILDERS | BFI | C | 10/30/2014 | | DALE | DALE | | BFI | C | 4844988 |
BUILTRITE BUILDERS | BFT | C | 10/30/2014 | ok per eng. | DALE | DALE | | BFT | C | 4844983 |
BUILTRITE BUILDERS | BFN | C | 10/30/2014 | ok per eng. / all paperwork on file / float / ufer in per eng. | DALE | DALE | | BFN | C | 4844982 |
BUILTRITE BUILDERS | BFD | C | 10/30/2014 | | DALE | DALE | | BFD | C | 4844974 |
HOMERUN ELECTRONICS, INC. | E= | C | 05/04/2015 | | MATTHEW | MATTHEW | | E= | C | 4948706 |
HOMERUN ELECTRONICS, INC. | E= | R | 04/24/2015 | need grout around front exterior outlet, label service disconnect, ground handi-box extension rings at fireplaces and install arc shields (leave cover plates off for re-inspect), final grade mark on mtve pedestal is still 1' higher than actual grade (need service lateral lowered or grade raised)--------- 40 amp a/c | MATTHEW | MATTHEW | | E= | R | 4942760 |
HOMERUN ELECTRONICS, INC. | E= | R | 03/03/2015 | not ready at this time | CRAIG | CRAIG | | E= | R | 4911033 |
HOMERUN ELECTRONICS, INC. | ER | C | 03/03/2015 | | CRAIG | CRAIG | | ER | C | 4911031 |
HOMERUN ELECTRONICS, INC. | ES | C | 02/18/2015 | Residential Underground: 200 amp 3/w: new res----- meter is set; need seal | MATTHEW | MATTHEW | | ES | C | 4904623 |
HOMERUN ELECTRONICS, INC. | ER | R | 02/18/2015 | install well wire, remove wiring from pocket door in basement bathroom------------------ finished basement, no mcc's, #6al, no cen vac | MATTHEW | MATTHEW | | ER | R | 4904620 |
HOMERUN ELECTRONICS, INC. | EUG | P | 11/12/2014 | install 2" pvc inspection conduit so we can check depth on final grade at pedestal | MATTHEW | MATTHEW | | EUG | P | 4852591 |
HOMERUN ELECTRONICS, INC. | EUG | P | 11/10/2014 | not deep enough at pedestal----- rest ok to backfill | MATTHEW | MATTHEW | | EUG | P | 4851603 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | H= | C | 05/01/2015 | Valve has been installed, final ok. | MARK | MARK | | H= | C | 4947237 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | H= | P | 04/14/2015 | Need shut off valve on gas line at cooktop, rest ok. Note: finished basement, louvered door to mech, full a/c, mantels ok. | MICHAELS | MICHAELS | | H= | P | 4935359 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HC | C | 02/20/2015 | RELEASE METER | MICHAELS | MICHAELS | | HC | C | 4906631 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HRR | C | 02/20/2015 | Corrections made. | MICHAELS | MICHAELS | | HRR | C | 4906630 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HRR | P | 02/19/2015 | Furn vent (Exhaust) needs repair in mech rm, hole in return above closet basement. Note: Equip matches, a/c rough. OSA. | MARK | MARK | | HRR | P | 4905535 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HRR | R | 02/17/2015 | No fall protection on stairs, open return to dead space with electrical on main, need insulation shield above wall on fp vent. Re-inspect all. | MICHAELS | MICHAELS | | HRR | R | 4903754 |
RIDGEVIEW PLUMBING | HI | C | 02/02/2015 | 10 lb test is good. Note: 1 1/4" main, 1-F, 2-w/.h, cook top, future bbq, 2-f/p. Note: No valve on cook top stub, check at final. | MARK | MARK | | HI | C | 4894591 |
RIDGEVIEW PLUMBING | P= | C | 04/29/2015 | NOTE : FINISHED BASEMENT , PVB INSTALLED , POTABLE WATER CERT TO SCANNING | GABE | GABE | | P= | C | 4945259 |
RIDGEVIEW PLUMBING | PTO | C | 02/02/2015 | NOTE : FINISHED BASEMENT , IRRIGATION STUB | GABE | GABE | | PTO | C | 4894688 |
BUILTRITE BUILDERS | PWO | C | 12/02/2014 | POTABLE WATER CERT BY FINAL | GABE | GABE | | PWO | C | 4863118 |
RIDGEVIEW PLUMBING | PB | C | 11/04/2014 | | TIM | TIM | | PB | C | 4847939 |