RAY - ECCHER SERVICES, LLC | B= | C | 05/28/2015 | | DALE | DALE | | B= | C | 4962553 |
RAY - ECCHER SERVICES, LLC | BIN | C | 03/27/2015 | | DANE | DANE | | BIN | C | 4925265 |
RAY - ECCHER SERVICES, LLC | BFR | C | 03/27/2015 | items from previous inspection complete | DANE | DANE | | BFR | C | 4925264 |
RAY - ECCHER SERVICES, LLC | BFR | P | 03/25/2015 | still need anchor bolts on north side of garage door/need to attach bearing for triple beam to beam/need to roll block all truss heels over 8" measured vertically on the inside of the wall/H2.5s done and straps at south beam done and lateral bracing of mono trusses done. | DANE | DANE | | BFR | P | 4923687 |
RAY - ECCHER SERVICES, LLC | BFR | R | 03/20/2015 | 3 ply beam not bearing, missing H.2 5 HTS 20's anchor bolts at plate breaks, glue lam not tied into top plate, block inbetween mono trusses -- no truss calcs on site all areas marked out on plans | ED | ED | | BFR | R | 4921208 |
RAY - ECCHER SERVICES, LLC | BFT | C | 02/10/2015 | porch piers ok | DALE | DALE | | BFT | C | 4900092 |
RAY - ECCHER SERVICES, LLC | BFN | C | 11/17/2014 | open hole on file | DALE | DALE | | BFN | C | 4854763 |
RAY - ECCHER SERVICES, LLC | BFT | P | 11/14/2014 | need open hole | DALE | DALE | | BFT | P | 4853869 |
ROCKY MOUNTAIN ELECTRICAL SERVICES INC | E= | C | 04/16/2015 | | MATTHEW | MATTHEW | | E= | C | 4937660 |
ROCKY MOUNTAIN ELECTRICAL SERVICES INC | EUG | P | 04/03/2015 | #2al feeder ok------- leave ditch open at garage------riser needs to be changed to sch 80 pvc | MATTHEW | MATTHEW | | EUG | P | 4929321 |
ROCKY MOUNTAIN ELECTRICAL SERVICES INC | EUG | R | 04/02/2015 | need equipment ground and schedule 80 pvc | MATTHEW | MATTHEW | | EUG | R | 4928674 |
ROCKY MOUNTAIN ELECTRICAL SERVICES INC | ER | C | 03/20/2015 | | MATTHEW | MATTHEW | | ER | C | 4921067 |
ROCKY MOUNTAIN RADIANT HEATING & PLUMBING, INC. | H= | C | 04/30/2015 | outside gas piping | TED | TED | | H= | C | 4946474 |
T & N DESIGN LLC | H= | C | 04/13/2015 | unit heaters and inside gas piping | TED | TED | | H= | C | 4934651 |
ROCKY MOUNTAIN RADIANT HEATING & PLUMBING, INC. | HO | C | 04/01/2015 | 10lb test on new p.e. from old line to new barn | TED | TED | | HO | C | 4927595 |
T & N DESIGN LLC | HI | C | 03/20/2015 | correction made | TED | TED | | HI | C | 4920846 |
T & N DESIGN LLC | HI | R | 03/12/2015 | low test, note:1'' 2-unit heaters | TED | TED | | HI | R | 4915871 |
T & N DESIGN LLC | HV | C | 03/12/2015 | 2-unit heater vents | TED | TED | | HV | C | 4915870 |