ELITE PROPERTIES OF AMERICA, INC. | B= | C | 05/27/2015 | corrections from previous inspection completed | BRIANB | BRIANB | | B= | C | 4961180 |
ELITE PROPERTIES OF AMERICA, INC. | B= | P | 05/26/2015 | seal garage door bracket at sheet rock ; basement unfinished -- Schedule a new Building Final when above items are complete. | DAN | DAN | | B= | P | 4960405 |
ELITE PROPERTIES OF AMERICA, INC. | B= | L | 05/22/2015 | house locked 11:02a | BRIANB | BRIANB | | B= | L | 4959496 |
ELITE PROPERTIES OF AMERICA, INC. | BLA | C | 03/23/2015 | | BRIANB | BRIANB | | BLA | C | 4921706 |
ELITE PROPERTIES OF AMERICA, INC. | BFR | C | 03/12/2015 | corrections completed | BRIANB | BRIANB | | BFR | C | 4915922 |
ELITE PROPERTIES OF AMERICA, INC. | BIN | C | 03/12/2015 | | BRIANB | BRIANB | | BIN | C | 4915920 |
ELITE PROPERTIES OF AMERICA, INC. | BFR | P | 03/09/2015 | OK to insulate/missing STHD14 hold downs at portal frame/fireblock garage door bracket that is in drop/missing 3/8" lags at ledger in garage/need 4 2x6 point load under rear kitchen window/need 3 2x6 PL under east great room window | DANE | DANE | | BFR | P | 4913862 |
ELITE PROPERTIES OF AMERICA, INC. | BSP | P | 03/05/2015 | front porch post and lid okay | BRIANB | BRIANB | | BSP | P | 4911932 |
ELITE PROPERTIES OF AMERICA, INC. | BFD | C | 12/10/2014 | | BLAKE | BLAKE | | BFD | C | 4868659 |
ELITE PROPERTIES OF AMERICA, INC. | BFN | C | 12/01/2014 | design and soils on file / drain entire structure / ufer rod in | JOND | JOND | | BFN | C | 4862376 |
ELITE PROPERTIES OF AMERICA, INC. | BFT | C | 11/21/2014 | pads ok | JIMA | JIMA | | BFT | C | 4858864 |
FOUNTAIN VALLEY ELECTRICAL, LLC | E= | C | 04/17/2015 | A.C PRE WIRE | MIKEC | MIKEC | | E= | C | 4938185 |
FOUNTAIN VALLEY ELECTRICAL, LLC | ES | C | 02/24/2015 | Residential Underground: NEW 200 AMP SERVICE | MIKEC | MIKEC | | ES | C | 4907486 |
FOUNTAIN VALLEY ELECTRICAL, LLC | ER | C | 02/24/2015 | NO CEN.VAC | MIKEC | MIKEC | | ER | C | 4907483 |
FOUNTAIN VALLEY ELECTRICAL, LLC | ES | R | 02/20/2015 | NOT READY | MIKEC | MIKEC | | ES | R | 4906717 |
FOUNTAIN VALLEY ELECTRICAL, LLC | ER | R | 02/20/2015 | MAKE UP NOT COMPLETE | MIKEC | MIKEC | | ER | R | 4906715 |
REGIONAL HEATING AND AIR CONDITIONING, INC. | H= | C | 04/27/2015 | Note: no mantle at fireplace, condenser not installed at this time. rest o.k. | STEVEC | STEVEC | | H= | C | 4943476 |
REGIONAL HEATING AND AIR CONDITIONING, INC. | H= | L | 04/24/2015 | | STEVEC | STEVEC | | H= | L | 4942852 |
REGIONAL HEATING AND AIR CONDITIONING, INC. | HC | C | 03/06/2015 | RELEASE METER | DICK | DICK | | HC | C | 4913052 |
REGIONAL HEATING AND AIR CONDITIONING, INC. | HRR | C | 03/06/2015 | corrections made. | DICK | DICK | | HRR | C | 4913047 |
REGIONAL HEATING AND AIR CONDITIONING, INC. | HRR | L | 02/27/2015 | Canceled. | STEVEC | STEVEC | | HRR | L | 4909464 |
REGIONAL HEATING AND AIR CONDITIONING, INC. | HRR | P | 02/23/2015 | FRAME AROUND B-VENT ON MAIN FLOOR. INSTALL PROPER REDUCER IN MAIN FLOOR BATH EXHAUST, DO NOT PUT SMALLER PIPE INTO LARGER ONE AND TAPE TOGETHER. WHERE IS THE 265 CFM RETURN AIR IN KITCHEN AREA SHOWN ON DUCT DESIGN? REPAIR ALL INSULATION SLEEVE ON BATH EXHAUST IN ATTIC. INSULATE BATH EXHAUST IN ATTIC ALL THE WAY TO ROOF DECK. EXTEND VENT SHIELD UP VERTICALLY, VENT SHIELD TO BE 2 INCHES ABOVE INSULATION HEIGHT. NOTE: UNFINISHED BASEMENT. OUTSIDE AIR TO FURNACE RETURN. A/C ROUGH, COIL AND LINESET. DIRECT VENT FURNACE. | NANCY | NANCY | | HRR | P | 4907141 |
PRECISION PLUMBING | HI | C | 02/19/2015 | 10# test ok. | MICHAELS | MICHAELS | | HI | C | 4904941 |
PRECISION PLUMBING | HI | P | 02/18/2015 | Low test. 1 1/4" main to furn, w/h, fp, range. | MICHAELS | MICHAELS | | HI | P | 4904102 |
PRECISION PLUMBING | P= | C | 05/08/2015 | unfinished basement. | DICK | DICK | | P= | C | 4951551 |
PRECISION PLUMBING | PTO | C | 02/26/2015 | CORRECTIONS MADE , | GABE | GABE | | PTO | C | 4909146 |
PRECISION PLUMBING | PTO | R | 02/17/2015 | NEEDS FREEZE PROTECTION UNDER P- TRAP GARAGE CEILING, WAIVED TRIP-FEE, TEST OK | TAYLOR | TAYLOR | | PTO | R | 4903230 |
PRECISION PLUMBING | PB | C | 01/09/2015 | COPPER STUBBED UNDER FOOTER | GABE | GABE | | PB | C | 4883189 |