DOUBLE DIAMOND HOMES, INC. | B= | C | 08/31/2015 | | BOBF | BOBF | | B= | C | 5027248 |
DOUBLE DIAMOND HOMES, INC. | B= | R | 08/28/2015 | locked at 4:30 | DALE | DALE | | B= | R | 5025128 |
DOUBLE DIAMOND HOMES, INC. | BSP | P | 06/08/2015 | deck membraine installed | ED | ED | | BSP | P | 4968554 |
DOUBLE DIAMOND HOMES, INC. | BFR | C | 04/13/2015 | eng. on file | DALE | DALE | | BFR | C | 4934643 |
DOUBLE DIAMOND HOMES, INC. | BLA | C | 04/08/2015 | | DALE | DALE | | BLA | C | 4932154 |
DOUBLE DIAMOND HOMES, INC. | BFR | R | 03/11/2015 | items completed, engineering on file for log posts ((( at clearance flue box in basement, top and bottom cords of floor joist cut out -- need engineer repair or add full length sistered joist-- this area NOT ok to drywall, also need stair inspection when stairs are installed))) | ED | ED | | BFR | R | 4915212 |
DOUBLE DIAMOND HOMES, INC. | BIN | P | 03/11/2015 | insulation ok, see added frame notes | ED | ED | | BIN | P | 4915211 |
DOUBLE DIAMOND HOMES, INC. | BFR | R | 03/05/2015 | need narrow braced wall per plan / nee k studs per plan / need exaust at tubs / need eng. for posts / ok to insulate | DALE | DALE | | BFR | R | 4912118 |
DOUBLE DIAMOND HOMES, INC. | BFR | R | 03/02/2015 | To many items to list. Reinspect all
| DALE | DALE | | BFR | R | 4910110 |
DOUBLE DIAMOND HOMES, INC. | BSP | P | 02/02/2015 | porch frame lid only ok | DALE | DALE | | BSP | P | 4895020 |
DOUBLE DIAMOND HOMES, INC. | BSP | R | 01/23/2015 | still need screws at ledger | DALE | DALE | | BSP | R | 4889478 |
DOUBLE DIAMOND HOMES, INC. | BSP | R | 01/16/2015 | porch lid need screws in ledger | DALE | DALE | | BSP | R | 4886183 |
DOUBLE DIAMOND HOMES, INC. | BSP | P | 12/09/2014 | deck piers ok | DALE | DALE | | BSP | P | 4868188 |
DOUBLE DIAMOND HOMES, INC. | BFT | C | 11/07/2014 | ok per eng. | DALE | DALE | | BFT | C | 4850881 |
DOUBLE DIAMOND HOMES, INC. | BFN | P | 11/07/2014 | ok per eng. / all paperwork on file / float / ufer in per eng. | DALE | DALE | | BFN | P | 4850880 |
DOUBLE DIAMOND HOMES, INC. | BFD | C | 11/07/2014 | | DALE | DALE | | BFD | C | 4850879 |
DOUBLE DIAMOND HOMES, INC. | BFN | P | 11/06/2014 | AUTHORIZED INSPECTION BY ENGINEER | TERRI | TERRI | TERRI | BFN | P | 4849544 |
DOUBLE DIAMOND HOMES, INC. | BFT | P | 11/06/2014 | AUTHORIZED INSPECTION BY ENGINEER | TERRI | TERRI | TERRI | BFT | P | 4849543 |
POLARIZED ELECTRIC INC | E= | C | 08/27/2015 | | MATTHEW | MATTHEW | | E= | C | 5023891 |
POLARIZED ELECTRIC INC | E= | R | 08/26/2015 | provide means to check OH door outlets, where is spa outlet (needs to be at access and point to access)----------- post address for re-inspect | MATTHEW | MATTHEW | | E= | R | 5022804 |
POLARIZED ELECTRIC INC | E= | R | 08/24/2015 | expose ufer -------------- replace broken breakers in outside panel ------------- gfi garage door opener ----------master closet light needs to be enclosed ------------ afci hallway stair outlet ---------- can' t find jet tub outlet --------- a/c ok 20 amp -------------- note hot tub pre wire | CRAIG | CRAIG | | E= | R | 5021017 |
POLARIZED ELECTRIC INC | ER | C | 03/02/2015 | CHECK FOR MAIN BONDING JUMPER AT TIME OF FINAL | MATTHEW | MATTHEW | | ER | C | 4909865 |
POLARIZED ELECTRIC INC | ES | C | 03/02/2015 | Residential Underground: 200 amp 3/w: new res------ need meter set | MATTHEW | MATTHEW | | ES | C | 4909864 |
POLARIZED ELECTRIC INC | ES | R | 02/25/2015 | see rough | MATTHEW | MATTHEW | | ES | R | 4908316 |
POLARIZED ELECTRIC INC | ER | R | 02/25/2015 | provide paperwork for second kitchen, add outlet under switches at main entrance, add outlet(s) in loft, add outlet between closets in basement bedroom, install main bonding jumper or move grounding electrode conductor to neutral bar-------------------- finished basement, no cen vac, 8-3nm to main kithen cooking, 6-3nm to bedroom kitchen, sub-panel ok (not breakered) ---------- check mcc's at time of final | MATTHEW | MATTHEW | | ER | R | 4908315 |
POLARIZED ELECTRIC INC | EUG | C | 01/29/2015 | service lat from ped to house | MATTHEW | MATTHEW | | EUG | C | 4893040 |
BRUNO'S MECHANICAL INC. | H= | C | 08/27/2015 | Corrections made. | MICHAELS | MICHAELS | | H= | C | 5023638 |
BRUNO'S MECHANICAL INC. | H= | R | 08/25/2015 | Furnace vent termination not properly seated on east side, no termination fitting on west side, extend suction line insulation to face of coil on lower furnace east side, secure intake to furnace at same location, undercut basement bedroom door without ducted return. Note: finished basement, louvered door to mech/laundry, full a/c on upper system, no mantel on gas fireplace. | MICHAELS | MICHAELS | | H= | R | 5021791 |
BRUNO'S MECHANICAL INC. | HC | C | 02/25/2015 | RELEASE METER | MICHAELS | MICHAELS | | HC | C | 4908488 |
BRUNO'S MECHANICAL INC. | HRR | C | 02/25/2015 | Corrections made. Note: finished basement, 6" osa on system 1, no osa on system 2, a/c rough(coil and lineset) on both systems, direct vent furnace x2. AT FINAL: need MUA for laundry in basement. | MICHAELS | MICHAELS | | HRR | C | 4908487 |
BRUNO'S MECHANICAL INC. | HRR | P | 02/24/2015 | No approved plans found on site, bath fan not connected to box on main, b-vent lacks insulation shield and clearance to roof deck, re-inspect all. | MICHAELS | MICHAELS | | HRR | P | 4907816 |
BRUNO'S MECHANICAL INC. | HRR | L | 02/23/2015 | No access due to unsafe roads, re-call inspection. | MICHAELS | MICHAELS | | HRR | L | 4907160 |
CORNERSTONE PLUMBING INC | HI | C | 02/11/2015 | Correction made. | MICHAELS | MICHAELS | | HI | C | 4900523 |
CORNERSTONE PLUMBING INC | HI | P | 02/09/2015 | Fireplace valve must be inside box, rest ok. 1 1/2" main to 2-furn, 2-w/h, 3-dryer, fp, range. Note: other 2 fireplaces are wood burning. | MICHAELS | MICHAELS | | HI | P | 4899164 |
CORNERSTONE PLUMBING INC | HI | R | 02/06/2015 | Bad gauge, stuck at 14psi. | MICHAELS | MICHAELS | | HI | R | 4898096 |
CORNERSTONE PLUMBING INC | HO | C | 01/29/2015 | 10# test ok. 1" poly from meter to house. Need 2lb. letter, and labeling by final. Note: reg in place. | MICHAELS | MICHAELS | | HO | C | 4893409 |
CORNERSTONE PLUMBING INC | P= | C | 08/24/2015 | CORRECTIONS MADE , POTABLE WATER CERT TO SCANNING | GABE | GABE | | P= | C | 5020351 |
CORNERSTONE PLUMBING INC | P= | P | 08/21/2015 | SECURE MOP SINK AND LAUNDRY DINK IN GARAGE , BASEMENT TOILET LEAKING , NEED POTABLE WATER CERT , REST OK . NOTE : FINISHED BASEMENT , PVB INSTALLED | GABE | GABE | | P= | P | 5020019 |
CORNERSTONE PLUMBING INC | PTO | C | 02/09/2015 | CORRECTIONS MADE , FINISHED BASEMENT , IRRIGATION STUB | GABE | GABE | | PTO | C | 4898879 |
CORNERSTONE PLUMBING INC | PTO | P | 02/06/2015 | NO TEST ON WATER , LOST TEST ON LAV IN IN LAW SIDE , NEED TO SET TUBS . NOTE : FINISHED BASEMENT , NO IRRIGATION . NEED POTABLE WATER CERT BY FINAL | GABE | GABE | | PTO | P | 4898214 |
HOMEOWNER | PWO | C | 12/02/2014 | POTABLE WATER CERT BY FINAL | GABE | GABE | | PWO | C | 4863094 |
CORNERSTONE PLUMBING INC | PB | C | 11/21/2014 | | TIM | TIM | | PB | C | 4858207 |