HOMEOWNER | B= | C | 09/06/2019 | All required documentation for spray foam and DC315 on file | JUSTINL | JUSTINL | | B= | C | 6325995 |
HOMEOWNER | B= | R | 09/04/2019 | Reviewed items needed to address item 5 of previous final inspection / Rear patio enclosure on separate permit ( M48473 ) - Basement finish under separate permit ( M38084) / Other final inspection corrections complete / ES report for Foxblock on file | JUSTINL | JUSTINL | | B= | R | 6324234 |
HOMEOWNER | B= | R | 07/01/2019 | 1. Missing guard and handrail at entry stairs and garage to dwelling stairs / 2. Retaining wall exceeds 48" measured from grade to grade / 3. Missing handrail to basement / 4. Covered patio at master now inclosed - update plans to show enclosed patio - Will need frame inspection of patio enclosure / 5. Provide ES report for spray foam in garage walls - Basement rims to determine if thermal barrier is required / 6. Provide ES report for Foxblock ICF walls in basement / 7. Lid at vault in basement needs to be insulated or install insulated door at vault / 8. Mud and tape gyp at garage to dwelling / Unfinished basement / Rear deck | JUSTINL | JUSTINL | | B= | R | 6250688 |
HOMEOWNER | BFR | C | 06/06/2016 | | DALE | DALE | | BFR | C | 5215613 |
HOMEOWNER | BFR | R | 05/23/2016 | complete straping of top plates and complete fireplace | DALE | DALE | | BFR | R | 5206053 |
HOMEOWNER | BIN | P | 05/13/2016 | complete bfr | DALE | DALE | | BIN | P | 5199226 |
HOMEOWNER | BFR | R | 04/28/2016 | strap top plate that do not overlap / foam and firestop / garage step 7 3/4" max. / complete fireplace / deck piers ok / ok to insulate | DALE | DALE | | BFR | R | 5187222 |
HOMEOWNER | BTR | C | 03/30/2016 | | DALE | DALE | | BTR | C | 5166064 |
HOMEOWNER | BSP | R | 09/28/2015 | half of piers poured without inspection | DALE | DALE | | BSP | R | 5045622 |
HOMEOWNER | BFN | C | 09/18/2015 | no shear required | DALE | DALE | | BFN | C | 5039873 |
HOMEOWNER | BIN | P | 09/18/2015 | Qualified third party energy inspection documentation must be presented at time of final building (B=) inspection | INTERNET | INTERNET | | BIN | P | 5039063 |
HOMEOWNER | BFD | C | 08/04/2015 | | DALE | DALE | | BFD | C | 5007507 |
HOMEOWNER | BFD | R | 07/31/2015 | complete fabric over rock / soils on file | DALE | DALE | | BFD | R | 5005732 |
HOMEOWNER | BSP | P | 05/28/2015 | garage wall ok / soils at drain | DALE | DALE | | BSP | P | 4962391 |
HOMEOWNER | BFN | P | 05/27/2015 | stamed soils at drain | DALE | DALE | | BFN | P | 4961433 |
HOMEOWNER | BFT | C | 05/27/2015 | | DALE | DALE | | BFT | C | 4961431 |
HOMEOWNER | BFT | P | 04/22/2015 | house and interior pads ok | DALE | DALE | | BFT | P | 4940627 |
HOMEOWNER | E= | C | 01/18/2019 | E= OK----CORRECTION MADE------ | GREGM | GREGM | | E= | C | 6082768 |
HOMEOWNER | E= | R | 12/05/2018 | GFCI CAN NOT BE BEHIND WASHER ---- GFI BASEMENT OUTLETS----REST OK--- | GREGM | GREGM | | E= | R | 6043990 |
HOMEOWNER | E= | R | 02/01/2018 | outlet too close to hot tub, lights need to be outside 5' from tub and gfci protected, need complete raceway to hot tub controller, gfci all basement outlets, staple nm and protect around panel, need gfci breaker for washer, gfci outlet on deck by dining room door, afci per 2011 nec-------------- no a/c, hot tub installed | MATTHEW | MATTHEW | | E= | R | 5754983 |
HOMEOWNER | E= | R | 08/28/2017 | not ready -------- gave consultation | CRAIG | CRAIG | | E= | R | 5609428 |
HOMEOWNER | E= | R | 03/07/2017 | not ready; gave consultation | MATTHEW | MATTHEW | | E= | R | 5433903 |
HOMEOWNER | E= | R | 09/19/2016 | not ready; consultation | MATTHEW | MATTHEW | | E= | R | 5296939 |
HOMEOWNER | ER | C | 04/25/2016 | no mcc 2 - 6/3 cu unfinished basement no cen vac | CRAIG | CRAIG | | ER | C | 5184136 |
HOMEOWNER | ER | R | 03/30/2016 | consultation | MATTHEW | MATTHEW | | ER | R | 5166307 |
HOMEOWNER | ES | C | 11/02/2015 | Residential Underground: 200 amp 3/w new res no action needed | CRAIG | CRAIG | | ES | C | 5070874 |
HOMEOWNER | EUG | C | 10/26/2015 | remainder of service lateral to pedestal ok | MATTHEW | MATTHEW | | EUG | C | 5065522 |
HOMEOWNER | EUG | P | 10/12/2015 | pvc from house east-----------need to complete from east end to pedestal to the north 80' | MATTHEW | MATTHEW | | EUG | P | 5055818 |
HOMEOWNER | H= | C | 07/13/2018 | DIRECT VENT WATER HEATER X2 | JEFFL | JEFFL | | H= | C | 5902388 |
HOMEOWNER | HWP | P | 07/10/2018 | 60 LB TEST OK. WILL COMPLETE HWP AT FINAL. OK TO CALL FINAL WHEN READY. | KYLEW | KYLEW | | HWP | P | 5897299 |
HOMEOWNER | HWP | P | 07/09/2018 | NEED TO DISCUSS WITH OTHER INSPECTOR IN MORNING. WILL UPDATE AFTER THAT. | KYLEW | KYLEW | | HWP | P | 5896829 |
HOMEOWNER | HWP | P | 04/03/2018 | VENTS TO BOILER AND WATER HEATER ARE CORRECT MATERIAL PER MANUFACTURES INSTALLATIONS AND GLUE PROPERLY. 60# test ok to the north upper level side of home. | PAULO | PAULO | | HWP | P | 5806640 |
HOMEOWNER | HWP | P | 03/13/2018 | need the following-- proper vent material for water heater per manufactures installations (need to verify concealed venting to water heater for proper material per manufactures installations), proper 2- step glue process with purple primer per the IPC, installation manual to boiler for the verification of correct venting material. 60# test ok to the north upper level side of home. | PAULO | PAULO | | HWP | P | 5787501 |
HOMEOWNER | HRR | C | 04/27/2016 | Correction made. | JEFFL | JEFFL | | HRR | C | 5185424 |
HOMEOWNER | HV | C | 04/26/2016 | Vent ok. | JEFFL | JEFFL | | HV | C | 5185039 |
HOMEOWNER | HRR | P | 04/26/2016 | Dryer vent not complete. Rest ok. | JEFFL | JEFFL | | HRR | P | 5185033 |
HOMEOWNER | HC | C | 03/16/2016 | Release meter. | JEFFL | JEFFL | | HC | C | 5155918 |
HOMEOWNER | HI | C | 02/17/2016 | 10 LB. test ok. Notes-- 1 1/4'' main.. 1 boiler.. 1 bbq.. 1 dryer.. 1 range.. | JEFFL | JEFFL | | HI | C | 5136043 |
HOMEOWNER | HI | R | 02/12/2016 | Low test. Med pressure system required or increase main size to handle load. | MARK | MARK | | HI | R | 5133434 |
HOMEOWNER | HI | P | 01/13/2016 | Will final tomorrow morning pending research on regulator. Updated notes 1-15-16.. 1'' main undersized for load. | JEFFL | JEFFL | | HI | P | 5115645 |
HOMEOWNER | HWP | P | 08/07/2015 | 100# test good. ok to pour concrete.under slab hwp. | LUKE | LUKE | | HWP | P | 5010600 |
HOMEOWNER | P= | C | 02/01/2018 | Potable water cert. sent to scanning on 2/2/18 | SHANEN | SHANEN | | P= | C | 5754883 |
HOMEOWNER | PTO | C | 01/22/2016 | | TIM | TIM | | PTO | C | 5121450 |
HOMEOWNER | PTO | P | 01/21/2016 | 1/2 bath and kit ok nothing else on test | TIM | TIM | | PTO | P | 5120694 |
HOMEOWNER | PTO | R | 01/15/2016 | no test on dwv low test h2o | TIM | TIM | | PTO | R | 5117313 |
HOMEOWNER | PTO | L | 01/13/2016 | gate closed with beware of dog sign | TIM | TIM | | PTO | L | 5115283 |
HOMEOWNER | PWO | C | 06/29/2015 | | TIM | TIM | | PWO | C | 4982827 |
HOMEOWNER | PB | C | 06/29/2015 | | TIM | TIM | | PB | C | 4982751 |