TIFFANY HOMES, LLC. | B= | C | 07/16/2015 | All other required Final inspections are complete. (This is a computer generated result) | DALE | DALE | | B= | C | 4994497 |
TIFFANY HOMES, LLC. | B= | P | 06/16/2015 | finished basement, no deck. Additional Inspections Required (computer generated): External Agency Inspection HD= by HEALTHDEPT is not Completed yet. | DALE | DALE | | B= | P | 4974071 |
TIFFANY HOMES, LLC. | B= | R | 06/09/2015 | install house # on house / need guard rail at front porch. Additional Inspections Required (computer generated): External Agency Inspection HD= by HEALTHDEPT is not Completed yet. | DALE | DALE | | B= | R | 4969905 |
TIFFANY HOMES, LLC. | BLA | C | 04/02/2015 | lath OK | DANE | DANE | | BLA | C | 4928414 |
TIFFANY HOMES, LLC. | BIN | C | 03/20/2015 | clearances at flue and wood burning fire place in basement | ED | ED | | BIN | C | 4921207 |
TIFFANY HOMES, LLC. | BIN | P | 03/19/2015 | insulation ok --- need to maintain 1" clearance between combustibles at wood burning fire place in basement | ED | ED | | BIN | P | 4920409 |
TIFFANY HOMES, LLC. | BFR | C | 03/19/2015 | | ED | ED | | BFR | C | 4920408 |
TIFFANY HOMES, LLC. | BFR | P | 03/12/2015 | OK to insulate/secure steel posts in garage to beam/secure steel post in exterior wall to foundation/complete narrow bracing at garage doors/remove float blocks/strap stair stringers | DANE | DANE | | BFR | P | 4916305 |
TIFFANY HOMES, LLC. | BSP | P | 02/25/2015 | porch lids ok / need posts 6" off of dirt and certified, wood logs | DALE | DALE | | BSP | P | 4908517 |
TIFFANY HOMES, LLC. | BSP | C | 01/23/2015 | deck piers ok | DALE | DALE | | BSP | C | 4889598 |
TIFFANY HOMES, LLC. | BFI | C | 12/12/2014 | | DALE | DALE | | BFI | C | 4870779 |
TIFFANY HOMES, LLC. | BFT | C | 12/09/2014 | ok per eng. | DALE | DALE | | BFT | C | 4868187 |
TIFFANY HOMES, LLC. | BFN | C | 12/09/2014 | ok per eng. / all paperwork on file / float / ufer in per eng. | DALE | DALE | | BFN | C | 4868186 |
TIFFANY HOMES, LLC. | BFD | C | 12/09/2014 | | DALE | DALE | | BFD | C | 4868185 |
D & J QUALITY ELECTRIC INC | E= | C | 06/02/2015 | | BRET | BRET | | E= | C | 4965042 |
D & J QUALITY ELECTRIC INC | E= | T | 05/29/2015 | PAID (REC#1265226): bar gfi does not trip , step lights do not work , back feed breaker from main panel to gen panel needs tied down , basement bath has gfi on gfi , 8/3 nmb on 50 amp breakers ------ 25 amp a/c ok | TOMC | TOMC | | E= | T | 4963364 |
D & J QUALITY ELECTRIC INC | E= | R | 05/22/2015 | not ready----- complete re-inspect----- partial list: need 3r box under panel and neutral bonded to box, underground only 1' deep, breakers at generator panel not secured to panel, 8-3nm on 50 amp breakers------ inspected pole, underground, generator panel and service panel only------- is generator hook up to be future (no outlet)------ contractor needs to check house and recall when ready | MATTHEW | MATTHEW | | E= | R | 4959859 |
D & J QUALITY ELECTRIC INC | EUG | P | 04/15/2015 | underground at house ok------------ service lateral at pole will not have 2' of coverage; are they bringing in more dirt?, call me in the am | MATTHEW | MATTHEW | | EUG | P | 4936689 |
D & J QUALITY ELECTRIC INC | ES | C | 03/31/2015 | Residential Underground: 200 AMP 3/W SEAL METER NOTE GENERATOR PANEL BACK FEED BREAKER NOT SECURED IN PLACE CHECK ON FINAL | CRAIG | CRAIG | | ES | C | 4927201 |
D & J QUALITY ELECTRIC INC | EUG | P | 03/20/2015 | final 20' at pole and 10' at house need to be lowered------- rest ok | MATTHEW | MATTHEW | | EUG | P | 4920897 |
D & J QUALITY ELECTRIC INC | ER | C | 03/09/2015 | finished basement, no cen vac, 8-3 and 10-3nm to cooking; CHECK ALL PANELS AND MCC'S AT TIME OF SERVICE INSPECTION (VERIFY BACK FED BREAKERS ARE SECURED TO PANEL)-------------- PER CONTRACTOR WELL WIRING TO BE FED FROM GENERATOR PANEL AND ALL CONTROLS WILL BE OUTSIDE | MATTHEW | MATTHEW | | ER | C | 4913846 |
BRUNO'S MECHANICAL INC. | H= | C | 06/03/2015 | correction made | TED | TED | | H= | C | 4965662 |
BRUNO'S MECHANICAL INC. | H= | P | 06/01/2015 | A/C LINES IN BASEMENT NOT COMPLETE. REST OK. NOTE: UNFINISHED MECHANICAL ROOM DIRECT VENT FURNACES. | LUKE | LUKE | | H= | P | 4964595 |
BRUNO'S MECHANICAL INC. | HC | C | 03/11/2015 | RELEASE METER | TED | TED | | HC | C | 4915192 |
BRUNO'S MECHANICAL INC. | HRR | C | 03/11/2015 | finished basement, a/c rough on furnace for main level, outside air to basement furnace, no venting for garage unit heater (gas piping only), duct design | TED | TED | | HRR | C | 4915183 |
BRUNO'S MECHANICAL INC. | HRR | R | 03/10/2015 | No approved plans on site, re-inspect all. | MICHAELS | MICHAELS | | HRR | R | 4914509 |
ROCKY MOUNTAIN RADIANT HEATING & PLUMBING, INC. | HI | C | 03/05/2015 | 1 1/2'' 2-furnaces, water heater, fireplace, range, bbq, garage unit heater outlet | TED | TED | | HI | C | 4911947 |
ROCKY MOUNTAIN RADIANT HEATING & PLUMBING, INC. | P= | C | 06/08/2015 | NOTE: FINISHED BASEMENT , NO IRRIGATION , ROUGH FOR BAR ONLY . POTABLE WATER CERT TO SCANNING | GABE | GABE | | P= | C | 4968585 |
ROCKY MOUNTAIN RADIANT HEATING & PLUMBING, INC. | PTO | C | 03/06/2015 | correction made | TED | TED | | PTO | C | 4912727 |
ROCKY MOUNTAIN RADIANT HEATING & PLUMBING, INC. | PTO | P | 03/05/2015 | install 3 piece shower drain on master shower, note: finished basement | TED | TED | | PTO | P | 4911946 |
ROCKY MOUNTAIN RADIANT HEATING & PLUMBING, INC. | PB | C | 01/15/2015 | | TED | TED | | PB | C | 4885509 |
HOMEOWNER | PWO | C | 11/25/2014 | by final need certificate of potable water, note: yard hydrants back flow protected | TED | TED | | PWO | C | 4860328 |