TUSCANY HOMES LLC | B= | C | 11/16/2015 | | BOBF | BOBF | | B= | C | 5080625 |
TUSCANY HOMES LLC | B= | P | 08/07/2015 | deck stairs barricaded off everything else ok -- Schedule a new Building Final when above items are complete. | DALE | DALE | | B= | P | 5010254 |
TUSCANY HOMES LLC | BSP | P | 06/16/2015 | deck piers ok, missing ledger locks, and check post connections at next inspection | ED | ED | | BSP | P | 4974312 |
TUSCANY HOMES LLC | BSP | T | 06/15/2015 | PAID (REC#1268089) ADDITIONAL PLAN REVIEW TIME: $50 From: MICHAELA Add deck | MICHAELA | MICHAELA | | BSP | T | 4973605 |
TUSCANY HOMES LLC | BFR | C | 04/28/2015 | eng. on file for beam | DALE | DALE | | BFR | C | 4944778 |
TUSCANY HOMES LLC | BIN | P | 04/09/2015 | complete bfr | DALE | DALE | | BIN | P | 4932746 |
TUSCANY HOMES LLC | BFR | R | 04/09/2015 | header at garage and beam not complete | DALE | DALE | | BFR | R | 4932739 |
TUSCANY HOMES LLC | BFR | P | 04/03/2015 | OK to insulate/Fire block garage door brackets 1 1/2" past brackets/garage to house door calls 3 2x12 header/landing to upper level needs 2 2x6 post under 2 2x8 beam/plan calls 3" bearing at beam pocket in mech room | DANE | DANE | | BFR | P | 4929110 |
TUSCANY HOMES LLC | BLA | C | 03/12/2015 | | DANE | DANE | | BLA | C | 4916306 |
TUSCANY HOMES LLC | BTR | C | 03/10/2015 | | ED | ED | | BTR | C | 4914250 |
TUSCANY HOMES LLC | BSP | P | 02/19/2015 | narrow braced wall ok | DALE | DALE | | BSP | P | 4905423 |
TUSCANY HOMES LLC | BSP | P | 02/17/2015 | porch frame posts and connections ok / portal frame not per plans | DALE | DALE | | BSP | P | 4903850 |
TUSCANY HOMES LLC | BSP | T | 02/13/2015 | PAID (REC#1246202) no plans on site - looked everywhere in house | ED | ED | | BSP | T | 4902551 |
TUSCANY HOMES LLC | BFN | C | 12/04/2014 | ok per eng. / all paperwork on file / float / ufer in per eng. | DALE | DALE | | BFN | C | 4864766 |
TUSCANY HOMES LLC | BFT | C | 12/04/2014 | ok per eng. | DALE | DALE | | BFT | C | 4864764 |
TUSCANY HOMES LLC | BFD | C | 12/04/2014 | | DALE | DALE | | BFD | C | 4864761 |
TUSCANY HOMES LLC | BFI | C | 12/04/2014 | | DALE | DALE | | BFI | C | 4864760 |
MEYER ELECTRIC | E= | C | 08/04/2015 | | CRAIG | CRAIG | | E= | C | 5007684 |
MEYER ELECTRIC | E= | R | 08/03/2015 | install inter system bonding terminal ------------- wet bar puck light no power ---------- all puck lights need to be on class 2 xfmr not door bell xfmr | CRAIG | CRAIG | | E= | R | 5006733 |
MEYER ELECTRIC | E= | R | 07/31/2015 | a/c breaker to big ( min 28.1 max 45 ) ---------- back porch outlet to loose ------------- install inter system bonding ----------- front door bedroom outlet wired wrong ----------- top porch outlet no power ----------where is xfmr for puck lights ?? ------------- basement washer no power -------- gfi all outlets within 6' of wet bar sink ----------- no power to puck light in wet bar ------------ install breaker lock for double oven --------------- hot tub pre wire | CRAIG | CRAIG | | E= | R | 5005964 |
MEYER ELECTRIC | ES | C | 06/19/2015 | Residential Underground: 200 amp 3/w ( 4/0 urd ) 100 amp sub-panel ( #2 ser ) | TOMC | TOMC | | ES | C | 4976886 |
MEYER ELECTRIC | EUG | C | 05/01/2015 | 2 runs of first 3/w 4/0 al second 3/w 1/0 al all service laterals | CRAIG | CRAIG | | EUG | C | 4947733 |
MEYER ELECTRIC | EUG | T | 04/30/2015 | PAID (REC#1259534): correction not made | MATTHEW | MATTHEW | | EUG | T | 4946481 |
MEYER ELECTRIC | EUG | R | 04/29/2015 | need to comply with 230.2 (1/0 or larger), need wire at bottom of ditch | MATTHEW | MATTHEW | | EUG | R | 4945887 |
MEYER ELECTRIC | ER | C | 04/02/2015 | | MATTHEW | MATTHEW | | ER | C | 4928394 |
MEYER ELECTRIC | ER | R | 03/31/2015 | whips in living room what do they go to -------------- whips for stair lights ----------- whips for kitchen under cabinet lights ----------- install nm connector in basement fire place ------------------- add outlet in basement bedroom wall behind door ----------- main level bathroom floor heat leads need to be in conduit ------------- 3 - 20 2 - 10/3 to both dryers 4/w # 2 al to sub panel in finished basement 2 - 6/3 cu to double oven / hot tub 2 - 6/3 al to cook top / a/c | CRAIG | CRAIG | | ER | R | 4927200 |
MORNING STAR ELEVATOR, LLC. | HE= | C | 07/27/2015 | ELEVATOR COMPLETE | JOHNW | JOHNW | | HE= | C | 5000924 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | H= | C | 07/24/2015 | Hi/Lo grills added. Final ok. | MARK | MARK | | H= | C | 5000345 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | H= | P | 07/23/2015 | Need c/a to me ch rm. Rest ok. Note: No grills and solid door to mech rm.Fin. bsmnt, has 1- a/c. sealed comb furnaces. Nomantle on main lvl. | MARK | MARK | | H= | P | 4999176 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HC | C | 03/31/2015 | RELEASE METER | MARK | MARK | | HC | C | 4927161 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HRR | C | 03/31/2015 | All corrections have been completed. Rough ok. | MARK | MARK | | HRR | C | 4927160 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HRR | R | 03/19/2015 | seal great room return at floor between wall and open wood set, replace damaged great room fireplace vent, install basement laundry room dryer vent, note: finished basement, a/c rough on one furnace, duct design | TED | TED | | HRR | R | 4920041 |
WHITE BROS CUSTOM PLUMBING & HEATING | HI | C | 03/16/2015 | 1 1/2'' 2-furnaces, 2-water heaters, 3-fireplaces, range, bbq | TED | TED | | HI | C | 4917700 |
WHITE BROS CUSTOM PLUMBING & HEATING | HI | R | 03/12/2015 | Lost test. | MARK | MARK | | HI | R | 4915658 |
WHITE BROS CUSTOM PLUMBING & HEATING | P= | C | 07/28/2015 | potable water cert o.k | JOEL | JOEL | | P= | C | 5002278 |
WHITE BROS CUSTOM PLUMBING & HEATING | P= | P | 07/17/2015 | NOTE : VALVE FOR POT FILLER UNDER COOK TOP , AAV AT BAR . FINISHED BASEMENT , PVB INSTALLED . NEED POTABLE WATER CERT TO COMPLETE | GABE | GABE | | P= | P | 4995730 |
WHITE BROS CUSTOM PLUMBING & HEATING | PTO | C | 03/12/2015 | finished basement | TED | TED | | PTO | C | 4916049 |
TUSCANY HOMES LLC | PWO | C | 12/19/2014 | POTABLE WATER CERT BY FINAL . NOTE : RP IN PIT FOR YARD HYDRANT | GABE | GABE | | PWO | C | 4875299 |
WHITE BROS CUSTOM PLUMBING & HEATING | PB | C | 12/12/2014 | H20 STUBBED UNDER FOOTER . POTABLE WATER CERT BY FINAL | GABE | GABE | | PB | C | 4870654 |