B & N CONSTRUCTION, INC. | B= | C | 06/05/2015 | All other required Final inspections are complete. (This is a computer generated result) | DANE | DANE | | B= | C | 4968242 |
B & N CONSTRUCTION, INC. | B= | P | 06/04/2015 | . Additional Inspections Required (computer generated): External Agency Inspection N= by ENGINEERING is not Completed yet (Contact: City Engineering Inspections 719-385-5977). | DANE | DANE | | B= | P | 4966754 |
B & N CONSTRUCTION, INC. | BLA | C | 04/09/2015 | | DANE | DANE | | BLA | C | 4932783 |
B & N CONSTRUCTION, INC. | BIN | C | 03/16/2015 | | DAN | DAN | | BIN | C | 4917974 |
B & N CONSTRUCTION, INC. | BFR | C | 03/16/2015 | letter on file for timber beams to top of columns at front porch and as built is acceptable. | DAN | DAN | | BFR | C | 4917970 |
B & N CONSTRUCTION, INC. | BFR | P | 03/10/2015 | OK to insulate/steel shim ML at front wall in basement at theater room/secure all telepost bases/float wall under drop in basement/strap all headers that are cut into the top plates | DANE | DANE | | BFR | P | 4914530 |
B & N CONSTRUCTION, INC. | BSP | P | 03/09/2015 | Partial frame inspection. Checked roof hardware and truss posts only/nail off 4th hanger from rear at K1G /missing hanger on K5 truss | DANE | DANE | | BSP | P | 4913865 |
B & N CONSTRUCTION, INC. | BSP | P | 02/10/2015 | need engineer letter on front porch attachments of exposed beams to exposed posts/back deck framing OK/back porch lid and posts over deck OK | DANE | DANE | | BSP | P | 4900021 |
B & N CONSTRUCTION, INC. | BSP | P | 01/28/2015 | deck piers OK | DANE | DANE | | BSP | P | 4892009 |
B & N CONSTRUCTION, INC. | BFD | C | 12/19/2014 | | JOND | JOND | | BFD | C | 4875656 |
B & N CONSTRUCTION, INC. | BFI | C | 12/19/2014 | | JOND | JOND | | BFI | C | 4875655 |
B & N CONSTRUCTION, INC. | BFD | P | 12/18/2014 | drains ok, need walkout insulation done | JOND | JOND | | BFD | P | 4874304 |
B & N CONSTRUCTION, INC. | BFN | C | 12/11/2014 | received soils letter, open hole and fdtn design/ ufer installed at 2 locations | BLAKE | BLAKE | | BFN | C | 4870030 |
B & N CONSTRUCTION, INC. | BFT | C | 12/04/2014 | pads OK; Isolate pads and slab and float walls; 5% slope from foundation, drain useable area | DAN | DAN | | BFT | C | 4864979 |
HOMEOWNER | E= | C | 05/21/2015 | 30 AMP A.C. HOT TUB PREWIRE | MIKEC | MIKEC | | E= | C | 4958798 |
HOMEOWNER | ER | C | 03/09/2015 | CEN.VAC. INSTALLED | MIKEC | MIKEC | | ER | C | 4913713 |
HOMEOWNER | ES | C | 03/09/2015 | Residential Underground: NEW 200 AMP SERVICE | MIKEC | MIKEC | | ES | C | 4913712 |
BRUNO'S MECHANICAL INC. | H= | C | 05/22/2015 | Note: future unit heater in garage not installed at this time, clearances to fireplace mantles, rest o.k. | STEVEC | STEVEC | | H= | C | 4959866 |
UNIQUE RADIANT HTG. & PLBG. | HO | C | 03/23/2015 | Verified attachments. | STEVEC | STEVEC | | HO | C | 4921269 |
UNIQUE RADIANT HTG. & PLBG. | HO | P | 03/16/2015 | 10# test o.k. email verification needed. | STEVEC | STEVEC | | HO | P | 4917408 |
SPRINGS GAS, INC. | HC | C | 03/05/2015 | RELEASE METER | STEVEC | STEVEC | | HC | C | 4912131 |
SPRINGS GAS, INC. | HI | C | 03/05/2015 | 10# test o.k. | STEVEC | STEVEC | | HI | C | 4912130 |
BRUNO'S MECHANICAL INC. | HRR | C | 02/27/2015 | Rough o.k. Note: Basement finish, A/C line set on main only, duct design, 2-direct vent furnaces equipment matches, 1- outside air, 2-water heaters, vent rough in garage. | STEVEC | STEVEC | | HRR | C | 4909474 |
UNIQUE RADIANT HTG. & PLBG. | P= | C | 05/19/2015 | finished basement, pvb installed. | DICK | DICK | | P= | C | 4957366 |
UNIQUE RADIANT HTG. & PLBG. | PTO | C | 03/06/2015 | CORRECTIONS MADE , NOTE : CHECK TOILET CLEARANCE AT FINAL IN BATH NEXT TO STAIRS IN BASEMENT . | GABE | GABE | | PTO | C | 4913093 |
UNIQUE RADIANT HTG. & PLBG. | PTO | P | 03/05/2015 | LOW TEST MASTER DWV GAUGE -- NEED MIN 15" OFF FINISHED WALL FOR W/C AT 3/4 BATH IN BSMT AT FINAL | LEE | LEE | | PTO | P | 4911919 |
UNIQUE RADIANT HTG. & PLBG. | PB | C | 01/05/2015 | TEST OK | GABE | GABE | | PB | C | 4880613 |
UNIQUE RADIANT HTG. & PLBG. | PB | R | 01/02/2015 | lost test. | DICK | DICK | | PB | R | 4879688 |