SKY CREEK HOMES, LTD. | B= | C | 06/17/2016 | corrections completed | ERICR | ERICR | | B= | C | 5225150 |
SKY CREEK HOMES, LTD. | BSP | P | 05/20/2016 | retaining wall on permit J51651 is complete | DANE | DANE | | BSP | P | 5204185 |
SKY CREEK HOMES, LTD. | B= | P | 05/19/2016 | Hand rails on stairs missing / Check permit for retaining wall / Post address / Need ladder for attic access / Need zoning and fire final -- Schedule a new Building Final when above items are complete. Additional Inspections Required (computer generated): External Agency Inspection F= by FIREDEPT is not Completed yet (Contact: 385-5982, x2), External Agency Inspection N= by ENGINEERING is not Completed yet (Contact: City Engineering Inspections 719-385-5977), Plumbing Final Inspection is not Completed yet. | NICK | NICK | | B= | P | 5203255 |
SKY CREEK HOMES, LTD. | BLA | C | 02/16/2016 | | ERICR | ERICR | | BLA | C | 5134967 |
SKY CREEK HOMES, LTD. | BIN | P | 01/26/2016 | need attic rulers before final for blow in insulation / everything else ok | ERICR | ERICR | | BIN | P | 5123491 |
SKY CREEK HOMES, LTD. | BIN | P | 01/22/2016 | If not insulating the garage ceiling you need to have a draft stop separating the house from the garage in the trusses | ERICR | ERICR | | BIN | P | 5121362 |
SKY CREEK HOMES, LTD. | BFR | C | 01/22/2016 | corrections completed | ERICR | ERICR | | BFR | C | 5121356 |
SKY CREEK HOMES, LTD. | BFR | P | 01/20/2016 | Need Fh Strap north exterior wall over plumbing notch / Need to attach tele posts top plates to beams / Need draft and fire stop / ok to insulate | ERICR | ERICR | | BFR | P | 5119556 |
SKY CREEK HOMES, LTD. | BSP | P | 01/05/2016 | front porch deck frame and posts okay / no stairs installed | BRIANB | BRIANB | | BSP | P | 5110061 |
SKY CREEK HOMES, LTD. | BSP | P | 12/11/2015 | front and rear porch lid okay / check front porch post at frame / note - check drag strut detail at frame | BRIANB | BRIANB | | BSP | P | 5097602 |
SKY CREEK HOMES, LTD. | BFT | C | 11/18/2015 | foundation design on file | DANE | DANE | | BFT | C | 5080712 |
SKY CREEK HOMES, LTD. | BFD | P | 11/16/2015 | engineer observation report on file / need stamped copy of foundation design | DANE | DANE | | BFD | P | 5079619 |
SKY CREEK HOMES, LTD. | BFN | P | 11/16/2015 | engineer observation report on file / need stamped copy of foundation design | DANE | DANE | | BFN | P | 5079615 |
SKY CREEK HOMES, LTD. | BFT | P | 11/16/2015 | engineer observation report on file / need stamped copy of foundation design | DANE | DANE | | BFT | P | 5079610 |
SKY CREEK HOMES, LTD. | BFT | R | 10/12/2015 | footing and foundation poured without prior authorization for engineer inspection / need engineer stamped foundation design and engineer stamped footing and foundation observations by drain inspection | DANE | DANE | | BFT | R | 5055380 |
SKY CREEK HOMES, LTD. | BFT | P | 10/12/2015 | 2400 PSF / usable drain / foundation design number referenced is job# 140136 | DANE | DANE | | BFT | P | 5054893 |
SKY CREEK HOMES, LTD. | BSP | P | 07/15/2015 | engineering tests on file for retaining wall at rear of property | DANE | DANE | | BSP | P | 4993875 |
SKY CREEK HOMES, LTD. | BE | L | 06/24/2015 | Renewed at 6/24/2015 11:30:09 AM | MINDY | MINDY | | BE | L | 4979626 |
FIRST RATE ELECTRICAL SERVICES, INC. | E= | C | 05/05/2016 | Panel installed to account for separate circuit required for microwave, separate from oven. | DEAN | DEAN | | E= | C | 5192344 |
FIRST RATE ELECTRICAL SERVICES, INC. | E= | R | 05/04/2016 | cannot install sub panel in back of oven cabinet working space and height issues. remove and install dedicated micro circuit. note:45 amp a/c | BRET | BRET | | E= | R | 5191970 |
FIRST RATE ELECTRICAL SERVICES, INC. | E= | R | 05/03/2016 | home locked 11:42 | BRET | BRET | | E= | R | 5190592 |
FIRST RATE ELECTRICAL SERVICES, INC. | ES | C | 01/19/2016 | Residential Underground: 200 AMP 3-W NEW RES-----OK TO SET METER--------UFER IS IRREVERSIBLE ---- | BRIAN | BRIAN | | ES | C | 5117908 |
FIRST RATE ELECTRICAL SERVICES, INC. | ER | C | 01/19/2016 | NOTES---FINISHED BASEMENT---NO CENTRAL VAC-----SUB OK--- | BRIAN | BRIAN | | ER | C | 5117906 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | H= | C | 04/07/2016 | DUPLICATE. | JEFFB | JEFFB | | H= | C | 5172518 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | H= | C | 04/07/2016 | THE DRYER VENT IS COMPLETE. | JEFFB | JEFFB | | H= | C | 5172430 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | H= | P | 04/05/2016 | NO DRYER VENT. NOTES THE A/C IS COMPLETE AND THERE ARE 2 - FULLY LOUVERED DOOR TO THE MECHANICAL ROOM. | JEFFB | JEFFB | | H= | P | 5170117 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HC | C | 01/15/2016 | RELEASE METER | STEVEC | STEVEC | | HC | C | 5117326 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HRR | C | 01/15/2016 | Duct design, direct vent furnace, outside air to return, basement finish, coil and line-set prep conditioned partial crawl. | STEVEC | STEVEC | | HRR | C | 5117321 |
L & L GAS SHOP, LLC. | HI | C | 01/07/2016 | 10# GAS TEST GOOD.... | LUKE | LUKE | | HI | C | 5112263 |
L & L GAS SHOP, LLC. | HI | R | 01/06/2016 | NEED A 10# GAS TEST. 1'' MAIN, FURNACE WATER HEATER RANGE.. | LUKE | LUKE | | HI | R | 5110965 |
JOLLY PLUMBING & HEATING INC. | P= | C | 06/16/2016 | rp backflow preventer for irrigation | JOEL | JOEL | | P= | C | 5224114 |
JOLLY PLUMBING & HEATING INC. | PTO | C | 12/29/2015 | corrections made. | TAYLOR | TAYLOR | | PTO | C | 5106850 |
JOLLY PLUMBING & HEATING INC. | PTO | P | 12/22/2015 | low test H2O, need 3 1/2 inches for freeze protection at washer trap, install and test master tub trap, rest ok, finished basement, note: 2009 IPC. | TAYLOR | TAYLOR | | PTO | P | 5103612 |
JOLLY PLUMBING & HEATING INC. | PB | C | 10/29/2015 | | TAYLOR | TAYLOR | | PB | C | 5068083 |