TIMBER LODGE BUILDERS, INC. | B= | C | 07/30/2015 | items complete | DANE | DANE | | B= | C | 5004480 |
TIMBER LODGE BUILDERS, INC. | B= | P | 07/29/2015 | need tip outs at down spouts and down spout and tip out at right front corner of house -- Schedule a new Building Final when above items are complete. | DANE | DANE | | B= | P | 5003472 |
TIMBER LODGE BUILDERS, INC. | BLA | C | 06/05/2015 | | DANE | DANE | | BLA | C | 4967647 |
TIMBER LODGE BUILDERS, INC. | BSP | P | 06/02/2015 | deck framing and post OK | DANE | DANE | | BSP | P | 4964821 |
TIMBER LODGE BUILDERS, INC. | BIN | C | 06/02/2015 | | DANE | DANE | | BIN | C | 4964820 |
TIMBER LODGE BUILDERS, INC. | BFR | C | 05/29/2015 | all items corrected from previous inspection / engineering on file for cut joists, bearing block, ripped header, post under steel beam, and over span of joist in first floor | DANE | DANE | | BFR | C | 4963622 |
TIMBER LODGE BUILDERS, INC. | BFR | T | 05/22/2015 | PAID (REC#1264571) draft stop / missing fire stop at garage chase and top b-vent chase / missing all roof jacks / top flange cut BCI @ HVAC front of garage and @ HVAC above drop in rear of garage / bearing blocks at G1 truss not per plan - cut short / need eng. letter for ripped down header at 2nd floor bedroom window / front porch beam at garage wall post missing (2) H2.5 / top flange BCI cut @ HVAC above kit. sink / BCI over span by north exterior wall above kit. / basement stair landing not done per plans - strap, missing anchor bolts, (2) 2x4x36" post / basement stair landing ledger missing anchor bolts / wood shims used under beam at pocket / missing solid blocking at rear cantilever / basement window headers not on approved plans / basement bath walls missing wall float spikes / still need rear deck frame inspection | BRIANB | BRIANB | | BFR | T | 4959482 |
TIMBER LODGE BUILDERS, INC. | BSP | P | 05/20/2015 | 3 rear deck piers OK | DAN | DAN | | BSP | P | 4958152 |
TIMBER LODGE BUILDERS, INC. | BFI | C | 03/10/2015 | | DANE | DANE | | BFI | C | 4914269 |
TIMBER LODGE BUILDERS, INC. | BFD | C | 03/05/2015 | soils letter received / drain habitable to daylight at walkout both corners | BRIANB | BRIANB | | BFD | C | 4911930 |
TIMBER LODGE BUILDERS, INC. | BFD | R | 03/03/2015 | Remove snow from excavation | DANE | DANE | | BFD | R | 4911155 |
TIMBER LODGE BUILDERS, INC. | BFN | P | 03/03/2015 | need subsurface soils investigation that has drain design/engineer foundation inspection on file/Eufer noted/usable drain/2000 PSI/open hole on file/foundation design on file | DANE | DANE | | BFN | P | 4911154 |
TIMBER LODGE BUILDERS, INC. | BFT | C | 03/03/2015 | Engineer inspection report on file | DANE | DANE | | BFT | C | 4911153 |
TIMBER LODGE BUILDERS, INC. | BFN | P | 03/03/2015 | AUTHORIZED INSPECTION BY ENGINEER | RITA | RITA | RITA | BFN | P | 4910586 |
TIMBER LODGE BUILDERS, INC. | BFT | P | 03/03/2015 | AUTHORIZED INSPECTION BY ENGINEER | RITA | RITA | RITA | BFT | P | 4910585 |
WINTERS ELECTRIC, INC. | E= | C | 07/28/2015 | 20 AMP A.C | MIKEC | MIKEC | | E= | C | 5002474 |
WINTERS ELECTRIC, INC. | ES | C | 05/14/2015 | Residential Underground: NEW 200 AMP SERVICE | MIKEC | MIKEC | | ES | C | 4955039 |
WINTERS ELECTRIC, INC. | ER | C | 05/14/2015 | NO CEN. VAC | MIKEC | MIKEC | | ER | C | 4955038 |
ASAP | H= | C | 07/27/2015 | | STEVEC | STEVEC | | H= | C | 5001618 |
ASAP | H= | P | 07/22/2015 | Need fireplace installation instructions for clearances to flooring. Note: rest o.k. | STEVEC | STEVEC | | H= | P | 4998768 |
SPRINGS GAS, INC. | HC | C | 05/21/2015 | RELEASE METER | STEVEC | STEVEC | | HC | C | 4959278 |
SPRINGS GAS, INC. | HI | C | 05/21/2015 | 10# test o.k. 1"/14 main, fireplace, furnace, tank-less water heater, range. | STEVEC | STEVEC | | HI | C | 4958922 |
ASAP | HRR | C | 05/21/2015 | Note: duct design, equipment matches, AC rough, basement finish, outside air to return, transfer grills in place, | STEVEC | STEVEC | | HRR | C | 4958914 |
TEAM PLUMBING, INC. | P= | C | 07/27/2015 | finished basement. | DICK | DICK | | P= | C | 5001529 |
TEAM PLUMBING, INC. | PTO | C | 05/04/2015 | finished basement, no irrigation. | DICK | DICK | | PTO | C | 4948455 |
TEAM PLUMBING, INC. | PB | C | 03/19/2015 | CORRECTIONS MADE | GABE | GABE | | PB | C | 4920336 |
TEAM PLUMBING, INC. | PB | P | 03/17/2015 | LOST TEST ON COPPER , DWV OK | GABE | GABE | | PB | P | 4918766 |