BUILTRITE BUILDERS | B= | C | 06/03/2015 | | ED | ED | | B= | C | 4965676 |
BUILTRITE BUILDERS | B= | P | 04/30/2015 | complete installation of doors and hardware -- Schedule a new Building Final when above items are complete. Additional Inspections Required (computer generated): ADVANTAGE HEATING & COOLING Mechanical Final Inspection is not Completed yet. | BOBF | BOBF | | B= | P | 4946738 |
BUILTRITE BUILDERS | BIN | C | 04/08/2015 | | ED | ED | | BIN | C | 4931782 |
BUILTRITE BUILDERS | BFR | P | 04/08/2015 | draft stop top of gas fire place, seal top and bottom of pipe used for air air plentum can be seen at final inspection ( remove some tile in grid ceiling), framing pending other inspections reviewed job with Bob F | ED | ED | | BFR | P | 4931781 |
BUILTRITE BUILDERS | BSP | T | 04/07/2015 | PAID (REC#1254912) ADDITIONAL PLAN REVIEW TIME: $50 From: TCRIPPEN new splice page see clouds | TCRIPPEN | TCRIPPEN | | BSP | T | 4931248 |
POSITIVE ELECTRIC, LLC | ER | C | 04/28/2015 | | CRAIG | CRAIG | | ER | C | 4944313 |
POSITIVE ELECTRIC, LLC | E= | C | 04/28/2015 | correction made | CRAIG | CRAIG | | E= | C | 4944306 |
POSITIVE ELECTRIC, LLC | E= | R | 04/27/2015 | see notes | CRAIG | CRAIG | | E= | R | 4943443 |
POSITIVE ELECTRIC, LLC | ER | R | 04/27/2015 | install class two xfmr for low lights ---------- gfi all outlets within 6' of breaker room sink ------------ install grid wire for lights ----------- no power to outlets in office 7 ---------- install light in office 4 | CRAIG | CRAIG | | ER | R | 4943441 |
POSITIVE ELECTRIC, LLC | ER | R | 04/24/2015 | not ready install lights | CRAIG | CRAIG | | ER | R | 4942173 |
POSITIVE ELECTRIC, LLC | ER | P | 04/01/2015 | HAVE APPROVED SET OF PLANS ON SITE --------- WALLS ONLY FOR UNIT 205 OK | CRAIG | CRAIG | | ER | P | 4928002 |
ADVANTAGE HEATING AND COOLING | H= | C | 05/04/2015 | MECHANICAL FINAL OK. TEST AND BALANCE REPORT RECEIVED. | NANCY | NANCY | | H= | C | 4947991 |
ADVANTAGE HEATING AND COOLING | H= | P | 05/01/2015 | TEST AND BALANCE REPORT RECEIVED. NEED OUTSIDE AIR READING INCLUDED ON REPORT. SEE ROOFTOP AND OUTSIDE AIR SCHEDULE ON SHEET M-1. | NANCY | NANCY | | H= | P | 4947050 |
ADVANTAGE HEATING AND COOLING | H= | P | 04/30/2015 | MECHANICAL FINAL OK PENDING RECEIPT OF TEST AND BALANCE REPORT. | NANCY | NANCY | | H= | P | 4946862 |
RIDGEVIEW PLUMBING | H= | C | 04/29/2015 | GAS FINAL OK. | NANCY | NANCY | | H= | C | 4945972 |
WESTERN FIREPLACE SUPPLY, INC. | H= | C | 04/29/2015 | FIREPLACE FINAL OK. | NANCY | NANCY | | H= | C | 4945971 |
ADVANTAGE HEATING AND COOLING | H= | P | 04/29/2015 | INSTALL SUPPLY/RETURN IN COPY ROOM. INSULATE SUPPLY ABOVE OFFICE 1. PROVIDE TEST AND BALANCE REPORT. | NANCY | NANCY | | H= | P | 4945967 |
ADVANTAGE HEATING AND COOLING | H= | P | 04/24/2015 | SERVICE CLEARANCE FOR VAV--2? SEAL AND INSULATE DUCT AT VAV-1. COMPLETE INSULATION ABOVE OFFICE 1. SUPPLY/RETURN IN COPY ROOM ? SERVICE ACCESS TO VAV-5 ABOVE BREAK ROOM? RETURN AIR IN BREAK ROOM? PROVIDE TEST AND BALANCE REPORT. | NANCY | NANCY | | H= | P | 4942995 |
WESTERN FIREPLACE SUPPLY, INC. | HV | P | 04/07/2015 | ISOLATE FIREPLACE VENT FROM RETURN AIR PLENUM. ELECTRIC FIREPLACE REMOVED FROM PRINTS AND REPLACED WITH GAS FIREPLACE? | NANCY | NANCY | | HV | P | 4931331 |
WESTERN FIREPLACE SUPPLY, INC. | HV | P | 04/03/2015 | ISOLATE FIREPLACE VENT FROM RETURN AIR PLENUM. VENT TERMINATES WITHIN 10 FEET OF RTU ECONOMIZER. FRAMING CLEARANCES FOR FIREPLACE OK. | NANCY | NANCY | | HV | P | 4929606 |
RIDGEVIEW PLUMBING | HI | P | 04/03/2015 | NO GAS SHOWN ON PRINTS, NEED REVISED/APPROVED PRINTS SHOWING ACTUAL GAS LINE INSTALLED TO FIREPLACE. BY FINAL WEATHER PROTECT REGULATOR ON ROOF. | NANCY | NANCY | | HI | P | 4929605 |
ADVANTAGE HEATING AND COOLING | HD | P | 04/03/2015 | LOW PRESSURE TRUNK LINES AND LATERALS OK, OK TO CLOSE WRAP ON LATERALS. NO VAV'S, FLEX OR DIFFUSERS YET. | NANCY | NANCY | | HD | P | 4929604 |
RIDGEVIEW PLUMBING | P= | C | 04/29/2015 | SINK AND WATER TO ICE MAKER | GABE | GABE | | P= | C | 4945716 |
RIDGEVIEW PLUMBING | PTO | C | 04/06/2015 | AAV AT SINK BY FINAL | GABE | GABE | | PTO | C | 4930341 |
RIDGEVIEW PLUMBING | PTO | P | 04/03/2015 | need to test 2 inch drain line. | TAYLOR | TAYLOR | | PTO | P | 4929309 |