ASPEN VIEW HOMES, LLC | B= | C | 09/17/2015 | All other required Final inspections are complete. (This is a computer generated result) | DANE | DANE | | B= | C | 5038973 |
ASPEN VIEW HOMES, LLC | B= | P | 09/03/2015 | fireplace manual has been provided and the 14 1/2" deep hearth has been replaced with 20" hearth per manufacturers specs. Additional Inspections Required (computer generated): External Agency Inspection HD= by HEALTHDEPT is not Completed yet. | DANE | DANE | | B= | P | 5029378 |
ASPEN VIEW HOMES, LLC | B= | P | 08/28/2015 | need manufactures installation guide for the wood burning fireplace - hearth is 14 1/2" deep now -- Schedule a new Building Final when above items are complete. Additional Inspections Required (computer generated): External Agency Inspection HD= by HEALTHDEPT is not Completed yet. | DANE | DANE | | B= | P | 5025083 |
ASPEN VIEW HOMES, LLC | B= | P | 08/28/2015 | water test paperwork on file -- Schedule a new Building Final when above items are complete. Additional Inspections Required (computer generated): External Agency Inspection HD= by HEALTHDEPT is not Completed yet, Electrical Final Inspection is not Completed yet. | DANE | DANE | | B= | P | 5024231 |
ASPEN VIEW HOMES, LLC | BSP | P | 08/13/2015 | Footings ok | TOMG | TOMG | | BSP | P | 5014631 |
ASPEN VIEW HOMES, LLC | BLA | C | 07/02/2015 | | ED | ED | | BLA | C | 4986006 |
ASPEN VIEW HOMES, LLC | BLA | R | 07/01/2015 | seal around all exterior penetrations | ED | ED | | BLA | R | 4985247 |
ASPEN VIEW HOMES, LLC | BIN | C | 06/05/2015 | | ED | ED | | BIN | C | 4967816 |
ASPEN VIEW HOMES, LLC | BFR | C | 06/04/2015 | frame items completed, trusses ok. | ED | ED | | BFR | C | 4967066 |
ASPEN VIEW HOMES, LLC | BFR | P | 06/03/2015 | add bearing blocks to girders as per note 1 and 2, add (2) h2.5'5 to TO1, and at T10, trusses, broken gusset at T03 truss, missing 2 trimmers, 2 kings rear porch post and hardware not installed, pad out oint load below TO5G, add point load under LVL - northeast side, ok to insulate (did not inspect trusses) | ED | ED | | BFR | P | 4965909 |
ASPEN VIEW HOMES, LLC | BSP | P | 05/01/2015 | eng. for vault on file | DALE | DALE | | BSP | P | 4947577 |
ASPEN VIEW HOMES, LLC | BSP | P | 05/01/2015 | 2 36" piers at back, plan shows 3 | DALE | DALE | | BSP | P | 4947576 |
ASPEN VIEW HOMES, LLC | BSP | P | 05/01/2015 | narrow braced wall anf front porch frame ok | DALE | DALE | | BSP | P | 4947570 |
ASPEN VIEW HOMES, LLC | BFT | C | 03/23/2015 | | ED | ED | | BFT | C | 4921910 |
ASPEN VIEW HOMES, LLC | BFN | C | 03/23/2015 | | ED | ED | | BFN | C | 4921909 |
ASPEN VIEW HOMES, LLC | BFD | C | 03/23/2015 | engineer inspection letter for footing, foundation, foundation design, soils on file | ED | ED | | BFD | C | 4921906 |
ASPEN VIEW HOMES, LLC | BFI | C | 03/23/2015 | R 10 | ED | ED | | BFI | C | 4921901 |
ASPEN VIEW HOMES, LLC | BFN | P | 02/20/2015 | AUTHORIZED INSPECTION BY ENGINEER | REBECCA | REBECCA | REBECCA | BFN | P | 4905888 |
ASPEN VIEW HOMES, LLC | BFT | P | 02/20/2015 | AUTHORIZED INSPECTION BY ENGINEER | REBECCA | REBECCA | REBECCA | BFT | P | 4905887 |
PEAK ELECTRIC INC. | E= | C | 08/28/2015 | | BRET | BRET | | E= | C | 5024443 |
PEAK ELECTRIC INC. | E= | R | 08/26/2015 | gfci protect receptacle for wet bar dish disposal receptacle. add light and receptacle for vault room. note: 30 amp a/c wired. disconnect for r.v no receptacle, hot tub on site no circuit installed for it. spare 30 amp circuit to lower patio. | BRET | BRET | | E= | R | 5023159 |
PEAK ELECTRIC INC. | ES | C | 05/28/2015 | Residential Underground: 200 amp 3/w: new res----- meter set; need seal | MATTHEW | MATTHEW | | ES | C | 4962503 |
PEAK ELECTRIC INC. | ER | C | 05/28/2015 | | MATTHEW | MATTHEW | | ER | C | 4962502 |
PEAK ELECTRIC INC. | ES | R | 05/27/2015 | see notes | GARYL | GARYL | | ES | R | 4961006 |
PEAK ELECTRIC INC. | ER | R | 05/27/2015 | 1) need stackers where required, 2) need running boards for n/m protection with in 6' of attic access................. NOTES! finished basement, no cen/vac, 2- sub panels check for mcc's, | GARYL | GARYL | | ER | R | 4961005 |
PEAK ELECTRIC INC. | EUG | C | 04/03/2015 | service lateral from pedestal to home | MATTHEW | MATTHEW | | EUG | C | 4928907 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | H= | C | 08/24/2015 | Corrections made. | MICHAELS | MICHAELS | | H= | C | 5021071 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | H= | P | 08/21/2015 | NEED OUT SIDE AIR HOOKED BACK UP TO RETURN SO WE CAN GIVE MEDIA ROOM IT'S FRESH AIR, STILL NEED COMBUSTION AIR FOR MECHANICAL ROOM. REST OK. | LUKE | LUKE | | H= | P | 5019988 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | H= | P | 08/19/2015 | Exhaust damper on back painted shut, under cut main level bedroom doors without ducted return, mech room lacks combustion air, rest ok. Note: future gas line in garage-no b-vent at this time, finished basement, full a/c on main, a/c rough(coil and lineset) in bsmt, mantels ok. | MICHAELS | MICHAELS | | H= | P | 5018284 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | H= | L | 08/18/2015 | Field cancelled, not ready. | MICHAELS | MICHAELS | | H= | L | 5017270 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HC | C | 06/04/2015 | Release Meter | JACK | JACK | | HC | C | 4966836 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HRR | C | 06/02/2015 | CORRECTIONS MADE , NO VENT INSTALLED FOR FUTURE GARAGE HEATER | GABE | GABE | | HRR | C | 4964839 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HRR | P | 06/01/2015 | Missing bath fans in basement and main level, rest ok. Note: finished basement, 6" osa x2, a/c rough(coil and lineset) main level only, direct vent furnace x2. | MICHAELS | MICHAELS | | HRR | P | 4964419 |
MD SERVICE PLUMBING, INC. | HI | C | 05/27/2015 | 10# test ok. 2lb. 1" main from meter to mech. 1 1/4" main from reg in mech to 2-furn, 2-w/h, 2-fp, range, bbq. Note: 2lb. letter on file. | MICHAELS | MICHAELS | | HI | C | 4961377 |
MD SERVICE PLUMBING, INC. | HI | R | 05/20/2015 | No fall protection, no inspection. | MICHAELS | MICHAELS | | HI | R | 4958103 |
MD SERVICE PLUMBING, INC. | P= | C | 08/25/2015 | NOTE : VALVE FOR POT FILLER IN MEC , PVB INSTALLED , FINISHED BASEMENT , ALL OTHER WALL MOUNTED VALVES IN CABINET OF FIXTURE . | GABE | GABE | | P= | C | 5021921 |
MD SERVICE PLUMBING, INC. | PTO | C | 05/27/2015 | FALL PROTECTION INSTALLED , INSTALL AND TEST IRRIGATION AT FINAL | GABE | GABE | | PTO | C | 4961163 |
MD SERVICE PLUMBING, INC. | PTO | T | 05/20/2015 | PAID (REC#1263834): NO FALL PROTECTION AT STAIRS , IRRIGATION LINE NOT INSTALLED OR TESTED . PARTIAL CORRECTIONS MADE , VALVES INSTALLED ON WALL MOUNTED FAUCETS | GABE | GABE | | PTO | T | 4957813 |
MD SERVICE PLUMBING, INC. | PTO | P | 05/18/2015 | NEED VALVES AT ALL WALL MOUNTED FAUCETS , NEED TO RUN AND TEST IRRIGATION LINE , FALL PROTECTION REQUIRED AT STAIRS . NOTE : AAV AT BAR AND POTABLE WATER CERT BY FINAL | GABE | GABE | | PTO | P | 4956589 |
HOMEOWNER | PWO | C | 04/29/2015 | H2O SLEEVED THROUGH FOUNDATION | GABE | GABE | | PWO | C | 4945207 |
MD SERVICE PLUMBING, INC. | PB | C | 03/27/2015 | | GABE | GABE | | PB | C | 4924632 |