MORLEY ENTERPRISES | B= | C | 08/08/2016 | | DAN | DAN | | B= | C | 5263999 |
MORLEY ENTERPRISES | B= | R | 08/01/2016 | 1) complete mechanical final. 2) ANSI signage to bathroom. 3) rework all three grab bars to correction location and sizes. 4) Bathroom hardware need button lever lock on door. Additional Inspections Required (computer generated): Floodplain Final Inspection is not Completed yet, DESIGN SYSTEMS HEATING & AC Mechanical Final Inspection is not Completed yet. | DAN | DAN | | B= | R | 5258829 |
MORLEY ENTERPRISES | BFR | C | 08/01/2016 | Letter on file from Robert Maixner, B-2915 for post to support lvl beam. 2hr door front of electrial panel OK. Craw space will OK. | DAN | DAN | | BFR | C | 5258828 |
MORLEY ENTERPRISES | BSP | P | 03/04/2016 | double layer 5/8 rock on back side of rated wall in basement OK / Need to see front side | NICK | NICK | | BSP | P | 5147999 |
MORLEY ENTERPRISES | BSP | T | 03/01/2016 | PAID (REC#1316280): left message @ 1130 am no one here @ 1230 pm | BERTW | BERTW | | BSP | T | 5145281 |
MORLEY ENTERPRISES | BFR | P | 12/17/2015 | Talked with Mike regarding accessible requirements in bathroom. 1) provide letter for bearing of 2 11 7/8" ml bearing on 2 1/2" pipe at front wall. 2) check 2hr access door to electrical panel at final. 3) complete 2hr wall in craw space. 4) by final will need dbl handrail front ramp; ramp width OK with occupancy load. stair need to be removed from plans or built as per plans. | DAN | DAN | | BFR | P | 5100856 |
BOULTON ELECTRICAL SERVICES | BSP | P | 11/13/2015 | PLAN SPLICE: (No Fee) by: SHELBY for Electrical: Change to P tak instead of mini split | SHELBY | SHELBY | | BSP | P | 5079259 |
MORLEY ENTERPRISES | BSP | P | 11/13/2015 | PLAN SPLICE FEE:by: DALEH for Mechanical: changed back to p-tac units | DALEH | DALEH | | BSP | P | 5079193 |
BOULTON ELECTRICAL SERVICES | BSP | T | 11/12/2015 | PAID (REC#1329128) PLAN SPLICE FEE: $50 by: DOUG for Electrical | DOUG | DOUG | | BSP | T | 5078072 |
MORLEY ENTERPRISES | BSP | P | 11/12/2015 | PLAN SPLICE FEE: by: DALEH for Mechanical: splice to add p-tacs and remove mini splits | DALEH | DALEH | | BSP | P | 5077983 |
MORLEY ENTERPRISES | BSP | P | 10/12/2015 | | SHELBY | SHELBY | | BSP | P | 5055573 |
MORLEY ENTERPRISES | BSP | T | 10/12/2015 | PAID (REC#1292711) PLAN SPLICE FEE: $50 by: TCRIPPEN for Plumbing: plumbing splice | TCRIPPEN | TCRIPPEN | | BSP | T | 5055514 |
MORLEY ENTERPRISES | BSP | T | 10/12/2015 | PAID (REC#1292711) PLAN SPLICE FEE: $50 by: MICHAELA for Construction: Revise floor plan - Revise occupancy classification | MICHAELA | MICHAELA | | BSP | T | 5055273 |
MORLEY ENTERPRISES | BSP | P | 07/07/2015 | 2 layers of rock and tape on main floor 2 hr wall laying down. need patch where old electrical panel was; need electrical inspection for relocated existing panel before wall is stood up. need fire barrier completed in craw space. | DAN | DAN | | BSP | P | 4987706 |
MORLEY ENTERPRISES | BSP | P | 07/07/2015 | 2HR rated fire barrier inspection main floor / reviewed IBC 707.5 Continuity / reviewed concealed spaces and openings in fire barriers | BRIANB | BRIANB | | BSP | P | 4987634 |
MORLEY ENTERPRISES | BSP | P | 04/10/2015 | Talked with Mike regarding the 2 hr separation wall and how to build it and when need to have a inspection called out | DAN | DAN | | BSP | P | 4933902 |
MORLEY ENTERPRISES | BSP | R | 04/09/2015 | cancelled by contractor due to health issue.; He will reschedule. | DAN | DAN | | BSP | R | 4932654 |
BOULTON ELECTRICAL SERVICES | E= | C | 05/12/2016 | | MIKEC | MIKEC | | E= | C | 5198338 |
BOULTON ELECTRICAL SERVICES | ES | R | 10/30/2015 | NEED PLANS REVISED TO SHOW WHAT IS BEING INSTALLED. ADDRESSING ISSUES ? | MIKEC | MIKEC | | ES | R | 5070018 |
BOULTON ELECTRICAL SERVICES | ER | C | 10/30/2015 | | MIKEC | MIKEC | | ER | C | 5070017 |
BOULTON ELECTRICAL SERVICES | ES | R | 08/28/2015 | Commercial Service: QUESTION ON PLANS AND ADDRESSING | MIKEC | MIKEC | | ES | R | 5025065 |
BOULTON ELECTRICAL SERVICES | ER | C | 08/28/2015 | | MIKEC | MIKEC | | ER | C | 5025058 |
BOULTON ELECTRICAL SERVICES | ES | C | 05/14/2015 | Commercial Service: 150 amp 0h need reconnect and reseal | MIKEC | MIKEC | | ES | C | 4954477 |
BOULTON ELECTRICAL SERVICES | ES | R | 05/12/2015 | STRAP RISER TO CSU SPECS | MIKEC | MIKEC | | ES | R | 4952890 |
MORLEY ENTERPRISES | FP= | C | 08/02/2016 | | KEITH | KEITH | BDA | FP= | C | 5259536 |
DESIGN SYSTEMS HEATING & AC | H= | C | 08/02/2016 | 4 LOUVERS INSTALLED | JERRYF | JERRYF | | H= | C | 5259642 |
DESIGN SYSTEMS HEATING & AC | H= | P | 07/29/2016 | NEED TO INSTALL OUTDOOR LOUVER'S .. NOTE: TEST AND BALANCE REPORT RECEIVED. | LUKE | LUKE | | H= | P | 5257979 |
DESIGN SYSTEMS HEATING & AC | HE | L | 07/28/2016 | Renewed at 7/28/2016 2:28:15 PM | KENYATTA | KENYATTA | | HE | L | 5256663 |
DESIGN SYSTEMS HEATING & AC | HD | P | 12/16/2015 | PTAC OK - AT FINAL VERIFY ALL FANS / LOUVERS / TRANSFER AND TAB REPORT FOR DISPENSARY | JERRYF | JERRYF | | HD | P | 5100099 |
LEO'S SEWER DRAIN PLUMBING | P= | C | 05/02/2016 | corrections made. | TAYLOR | TAYLOR | | P= | C | 5189761 |
LEO'S SEWER DRAIN PLUMBING | P= | P | 04/07/2016 | waive trip fee, need mixing valve at lav and cap old gas line, rest ok. | TAYLOR | TAYLOR | | P= | P | 5172429 |
LEO'S SEWER DRAIN PLUMBING | P= | R | 03/08/2016 | too many items to list. | TAYLOR | TAYLOR | | P= | R | 5150358 |
LEO'S SEWER DRAIN PLUMBING | PTO | C | 12/16/2015 | by final need aav on lav under sink, (developed length on trap arm over 9 feet on 1 1/2'' from trap outlet to vent in wall behind toilet), need expansion tank and vacuum breaker on water heater at final | TED | TED | | PTO | C | 5099834 |
LEO'S SEWER DRAIN PLUMBING | PTO | L | 12/15/2015 | need lock box code. | TAYLOR | TAYLOR | | PTO | L | 5099126 |
ANYTIME SEWER AND DRAIN | PTO | R | 11/18/2015 | need to pipe H2O per plan, test drain for lav, anchor closet flange, test H2O, add water heater and toilet to scope of work, need access to basement on next inspection, need mechanical permit attached, maybe more items to list. | TAYLOR | TAYLOR | | PTO | R | 5081198 |