ROBERT SCOTT GENERAL CONTRACTORS, INC. | B= | C | 04/15/2016 | corrections completed | ERICR | ERICR | | B= | C | 5178455 |
ROBERT SCOTT GENERAL CONTRACTORS, INC. | B= | P | 04/08/2016 | need window well cover on window well by patio / Need 18" landing outside of slider to patio / need insulation cert for blown insulation -- Schedule a new Building Final when above items are complete. Additional Inspections Required (computer generated): External Agency Inspection F= by FIREDEPT is not Completed yet (Contact: 385-5982, x2). | ERICR | ERICR | | B= | P | 5173313 |
ROBERT SCOTT GENERAL CONTRACTORS, INC. | BIN | C | 02/12/2016 | | DAN | DAN | | BIN | C | 5133843 |
ROBERT SCOTT GENERAL CONTRACTORS, INC. | BFR | C | 02/12/2016 | | DAN | DAN | | BFR | C | 5133834 |
ROBERT SCOTT GENERAL CONTRACTORS, INC. | BFR | P | 02/10/2016 | Need draft stop and fire blocking / Glue shims under all beams anchor bolt left side of garage on plate / garage door blocks / Received truss repair engineering / ok to insulate / Basement finish / need sign off on basement finish electric rough | ERICR | ERICR | | BFR | P | 5131896 |
ROBERT SCOTT GENERAL CONTRACTORS, INC. | BSP | T | 01/25/2016 | PAID (REC#1310008) ADDITIONAL PLAN REVIEW TIME: $50 From: SHELLEY Exterior wall protection due to fire separation distance. | SHELLEY | SHELLEY | | BSP | T | 5122822 |
ROBERT SCOTT GENERAL CONTRACTORS, INC. | BLA | C | 01/12/2016 | | DAN | DAN | | BLA | C | 5114408 |
ROBERT SCOTT GENERAL CONTRACTORS, INC. | BSP | P | 12/31/2015 | fornt porch 6x6 2 each OK; fix for J9 trusses inside of house, on site at frame. | DAN | DAN | | BSP | P | 5108419 |
ROBERT SCOTT GENERAL CONTRACTORS, INC. | BSP | P | 12/28/2015 | front porch trusses OK / correct size beams installed at front porch / need 6x6 post installed still / need engineer fix for bottom cord at J9 cut to fit into THJA hanger / post at south east corner will need to bear at both beams as the bottoms of the 2x12 beam and 11 7/8" ML beam do not set at same elevation | DANE | DANE | | BSP | P | 5105829 |
ROBERT SCOTT GENERAL CONTRACTORS, INC. | BSP | T | 11/05/2015 | PAID (REC#1297592) ADDITIONAL PLAN REVIEW TIME: $50 From: JIMA splice : deleated covered patio , new trusses | JIMA | JIMA | | BSP | T | 5073112 |
ROBERT SCOTT GENERAL CONTRACTORS, INC. | BFD | C | 06/25/2015 | usable drain complete to sump pit in basement | DANE | DANE | | BFD | C | 4980534 |
ROBERT SCOTT GENERAL CONTRACTORS, INC. | BFN | C | 06/17/2015 | Design on file / open hole on file / soils on file / 2000 PSF / 10% grade / usable drain / Eufer in | DANE | DANE | | BFN | C | 4974978 |
ROBERT SCOTT GENERAL CONTRACTORS, INC. | BFT | C | 06/09/2015 | including interior pads | DANE | DANE | | BFT | C | 4969954 |
ROBERT SCOTT GENERAL CONTRACTORS, INC. | BFN | P | 04/17/2015 | AUTHORIZED INSPECTION BY ENGINEER | MINDY | MINDY | MINDY | BFN | P | 4938325 |
ROBERT SCOTT GENERAL CONTRACTORS, INC. | BFT | P | 04/17/2015 | AUTHORIZED INSPECTION BY ENGINEER | MINDY | MINDY | MINDY | BFT | P | 4938324 |
SERVICE FIRST ELECTRIC | E= | C | 04/06/2016 | | BRET | BRET | | E= | C | 5171310 |
SERVICE FIRST ELECTRIC | E= | R | 04/05/2016 | arc-fault stairwell and rec room, gfci 2 receptacles within 6' of basement bathroom sink, a/c service receptacle cannot be fed from garage circuit, a/c receptacle not w/r type. note 15 amp a/c wired | BRET | BRET | | E= | R | 5170395 |
SERVICE FIRST ELECTRIC | ER | C | 02/08/2016 | BASEMENT | MIKEC | MIKEC | | ER | C | 5129758 |
SERVICE FIRST ELECTRIC | ES | C | 01/14/2016 | Residential Underground: 150 amp service new res. | BRET | BRET | | ES | C | 5116677 |
SERVICE FIRST ELECTRIC | ER | C | 01/14/2016 | #6 AL to range, no mcc,no vac, unfinished basement. 10 nma/c rough. | BRET | BRET | | ER | C | 5116666 |
GENE'S HEATING AND AIR LLC | H= | C | 04/06/2016 | THE BASEMENT IS FINISHED, 2 - 14 X 14 TRANSFER GRILLS, HIGH AND LOW, ON THE MECHANICAL ROOM WALL AND THE A/C IS COMPLETE. | JEFFB | JEFFB | | H= | C | 5171680 |
GENE'S HEATING AND AIR LLC | HRR+ | C | 02/09/2016 | | STEVEC | STEVEC | | HRR+ | C | 5130984 |
KAMPP-L ENTERPRISES, INC. | HI+ | C | 01/25/2016 | 10 LB TEST IS OK. 1 1/4" MAIN INTO THE HOUSE. | JEFFB | JEFFB | | HI+ | C | 5122620 |
GENE'S HEATING AND AIR LLC | HC | C | 01/15/2016 | RELEASE METER | STEVEC | STEVEC | | HC | C | 5117264 |
GENE'S HEATING AND AIR LLC | HRR | C | 01/15/2016 | Duct design, equipment matches, unfinished basement, outside air to return, coil and line-set prep. | STEVEC | STEVEC | | HRR | C | 5117260 |
KAMPP-L ENTERPRISES, INC. | HI | C | 01/04/2016 | Pressure test OK. Note: 11/4" blk - furnace, water heater, kitchen range and BBQ | MARKB | MARKB | | HI | C | 5109386 |
KAMPP-L ENTERPRISES, INC. | P= | C | 04/07/2016 | finished basement, no irrigation. | TAYLOR | TAYLOR | | P= | C | 5172134 |
KAMPP-L ENTERPRISES, INC. | PTO+ | C | 02/08/2016 | basement bath ok, note: VTR. | TAYLOR | TAYLOR | | PTO+ | C | 5129609 |
KAMPP-L ENTERPRISES, INC. | PTO | C | 12/29/2015 | corrections made. | TAYLOR | TAYLOR | | PTO | C | 5106888 |
KAMPP-L ENTERPRISES, INC. | PTO | P | 12/28/2015 | s-trap at master shower, need minimum of 1 inch clearance from b-vent to pex in basement, rest ok, note: vents through roof, unfinished basement, 2009 IPC. | TAYLOR | TAYLOR | | PTO | P | 5106068 |
KAMPP-L ENTERPRISES, INC. | PB | C | 10/22/2015 | correction made. | TAYLOR | TAYLOR | | PB | C | 5063334 |
KAMPP-L ENTERPRISES, INC. | PB | R | 10/21/2015 | can not water test when everything is wet. | TAYLOR | TAYLOR | | PB | R | 5062523 |
KAMPP-L ENTERPRISES, INC. | PB | P | 10/20/2015 | lost test. | TAYLOR | TAYLOR | | PB | P | 5061590 |