TRALON HOMES, LLC | B= | C | 10/19/2015 | All other required Final inspections are complete. (This is a computer generated result) | TOMG | TOMG | | B= | C | 5060778 |
TRALON HOMES, LLC | B= | P | 10/15/2015 | . Additional Inspections Required (computer generated): External Agency Inspection UBS by WOODWATER is not Completed yet (Contact: zachc@woodmoorwater.com), External Agency Inspection UWS by WOODWATER is not Completed yet (Contact: zachc@woodmoorwater.com). | TOMG | TOMG | | B= | P | 5058444 |
TRALON HOMES, LLC | BFR | C | 07/10/2015 | | TOMG | TOMG | | BFR | C | 4990451 |
TRALON HOMES, LLC | BIN | C | 07/10/2015 | | TOMG | TOMG | | BIN | C | 4990445 |
TRALON HOMES, LLC | BFR | R | 07/06/2015 | steel beams supporting 2nd floor still not welded together | BOBF | BOBF | | BFR | R | 4987057 |
TRALON HOMES, LLC | BIN | R | 07/06/2015 | frame still not complete | BOBF | BOBF | | BIN | R | 4987055 |
TRALON HOMES, LLC | BIN | R | 07/02/2015 | not ready | BOBF | BOBF | | BIN | R | 4985729 |
TRALON HOMES, LLC | BFR | P | 07/02/2015 | still need to weld steel beams and shims together supporting 2nd floor | BOBF | BOBF | | BFR | P | 4985722 |
TRALON HOMES, LLC | BFR | R | 07/01/2015 | weld steel beams and shims at main level / missing HTS 20 at mid point bearing of tr-29, missiing H 2.5 at south end of tr-29 / glue shims at steel beams in basement / okay to insulate | BOBF | BOBF | | BFR | R | 4985253 |
TRALON HOMES, LLC | BSP | P | 06/19/2015 | exterior nailing for narrow wall okay / provide engineer letter for STHD 14 at frame inspection | BOBF | BOBF | | BSP | P | 4976784 |
TRALON HOMES, LLC | BSP | P | 06/16/2015 | porch with middle post okay, outside post not installed / still needs narrow/portal wall inspection, not ready. Check detail regarding nailing and hold downs required | BOBF | BOBF | | BSP | P | 4973983 |
TRALON HOMES, LLC | BFD | C | 05/06/2015 | | BOBF | BOBF | | BFD | C | 4949930 |
TRALON HOMES, LLC | BFD | R | 05/05/2015 | need to seal plastic around all sides of foundation | BOBF | BOBF | | BFD | R | 4949206 |
TRALON HOMES, LLC | BFN | C | 05/05/2015 | eng letter for footing steel and eufer 0n file | BOBF | BOBF | | BFN | C | 4948859 |
TRALON HOMES, LLC | BFT | C | 05/05/2015 | open hole on file /2000 | BOBF | BOBF | | BFT | C | 4948852 |
TRALON HOMES, LLC | BSP | P | 05/05/2015 | design on file | BOBF | BOBF | | BSP | P | 4948850 |
TRALON HOMES, LLC | BFT | P | 04/20/2015 | AUTHORIZED INSPECTION BY ENGINEER | REBECCA | REBECCA | REBECCA | BFT | P | 4939083 |
TRALON HOMES, LLC | BFN | P | 04/20/2015 | AUTHORIZED INSPECTION BY ENGINEER | REBECCA | REBECCA | REBECCA | BFN | P | 4939084 |
FOUNTAIN VALLEY ELECTRICAL, LLC | E= | C | 07/29/2015 | | CRAIG | CRAIG | | E= | C | 5003698 |
FOUNTAIN VALLEY ELECTRICAL, LLC | ES | C | 07/02/2015 | Residential Underground: 150 amp 3/w new res seal meter | CRAIG | CRAIG | | ES | C | 4985971 |
FOUNTAIN VALLEY ELECTRICAL, LLC | ES | R | 07/01/2015 | Residential Underground: REMOVE TEMP SERVICE FROM PEDESTAL ----------- LAND SERVICE LATERAL IN PEDESTAL | CRAIG | CRAIG | | ES | R | 4985011 |
FOUNTAIN VALLEY ELECTRICAL, LLC | ER | C | 06/30/2015 | | CRAIG | CRAIG | | ER | C | 4983763 |
FOUNTAIN VALLEY ELECTRICAL, LLC | ES | R | 06/29/2015 | Remove temp service and terminate service conductors in utility pedestal | JOSEPH | JOSEPH | | ES | R | 4982807 |
FOUNTAIN VALLEY ELECTRICAL, LLC | ER | R | 06/29/2015 | Cable hanging from upstairs NW bedroom.----------- notes unfinished basement----------No central vac------------ 2 - 6/3 al 1 - 20 | JOSEPH | JOSEPH | | ER | R | 4982801 |
FOUNTAIN VALLEY ELECTRICAL, LLC | EUG | C | 06/22/2015 | 3/w 2/0 al service lateral | CRAIG | CRAIG | | EUG | C | 4977924 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | H= | C | 08/05/2015 | Final ok. Note: Unf. basement, no a/c. Has OSA to return. | MARK | MARK | | H= | C | 5008595 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HC | C | 06/23/2015 | RELEASE METER | MARK | MARK | | HC | C | 4979165 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HRR | C | 06/23/2015 | Rough ok. Unf bsmnt, no a/c. Has OSA to return and equip matches. | MARK | MARK | | HRR | C | 4979161 |
L & L GAS SHOP, LLC. | HI | C | 06/19/2015 | 10 # TEST OK . 1 FURNACE , 1 WATER HEATER | GABE | GABE | | HI | C | 4976586 |
KIMBEL MECHANICAL SYSTEMS, INC. | P= | C | 10/14/2015 | SECURE HOSE BIB IN FRONT , NOTE : UNFINISHED BASEMENT , PVB INSTALLED | GABE | GABE | | P= | C | 5057229 |
KIMBEL MECHANICAL SYSTEMS, INC. | PTO | C | 06/19/2015 | NOTE : UNFINISHED BASEMENT , IRRIGATION STUB | GABE | GABE | | PTO | C | 4976582 |
KIMBEL MECHANICAL SYSTEMS, INC. | PB | C | 05/07/2015 | COPPER STUBBED UNDER FOOTER4 | GABE | GABE | | PB | C | 4950725 |