GOEBEL CONSTRUCTION, INC | B= | C | 08/28/2015 | unfinished basement , deck in | DALE | DALE | | B= | C | 5025114 | GOEBEL CONSTRUCTION, INC | BLA | C | 07/07/2015 | | DALE | DALE | | BLA | C | 4988023 | GOEBEL CONSTRUCTION, INC | BIN | C | 07/06/2015 | | DALE | DALE | | BIN | C | 4987012 | GOEBEL CONSTRUCTION, INC | BFR | C | 07/01/2015 | | DALE | DALE | | BFR | C | 4985289 | GOEBEL CONSTRUCTION, INC | BFR | R | 06/30/2015 | complete ER / brace strong backs every 4ft / nail narrow braced wall per plan / anchor stair ledger | DALE | DALE | | BFR | R | 4983972 | GOEBEL CONSTRUCTION, INC | BSP | P | 06/26/2015 | front porch lid and post connections ok | ED | ED | | BSP | P | 4981486 | GOEBEL CONSTRUCTION, INC | BSP | P | 06/22/2015 | porch piers ok | DALE | DALE | | BSP | P | 4978160 | GOEBEL CONSTRUCTION, INC | BSP | P | 06/05/2015 | f porch lid only ok | DALE | DALE | | BSP | P | 4967911 | GOEBEL CONSTRUCTION, INC | BFD | C | 05/18/2015 | | DALE | DALE | | BFD | C | 4956579 | GOEBEL CONSTRUCTION, INC | BFI | C | 05/18/2015 | | DALE | DALE | | BFI | C | 4956578 | GOEBEL CONSTRUCTION, INC | BFT | C | 05/18/2015 | ok per eng. | DALE | DALE | | BFT | C | 4956572 | GOEBEL CONSTRUCTION, INC | BFN | C | 05/18/2015 | ok per eng. / all paperwork on file / float | DALE | DALE | | BFN | C | 4956571 | GOEBEL CONSTRUCTION, INC | BFN | P | 04/22/2015 | AUTHORIZED INSPECTION BY ENGINEER | JANE | JANE | JANE | BFN | P | 4940549 | GOEBEL CONSTRUCTION, INC | BFT | P | 04/22/2015 | AUTHORIZED INSPECTION BY ENGINEER | JANE | JANE | JANE | BFT | P | 4940548 | MESA ELECTRIC, LLC. | E= | C | 08/26/2015 | | MATTHEW | MATTHEW | | E= | C | 5023050 | MESA ELECTRIC, LLC. | ES | C | 08/25/2015 | Residential Underground: 200 amp 3/w: new res---- meter is set; need seal | MATTHEW | MATTHEW | | ES | C | 5021953 | MESA ELECTRIC, LLC. | E= | P | 08/25/2015 | afci #18 will not set------------- 30 amp a/c ok-------- #4al ser to 50 amp sub-panel ok | MATTHEW | MATTHEW | | E= | P | 5021947 | MESA ELECTRIC, LLC. | EUG | C | 08/06/2015 | service lateral from pedestal to pole | MATTHEW | MATTHEW | | EUG | C | 5009496 | MESA ELECTRIC, LLC. | ES | R | 08/06/2015 | MTVE neutral connection needs to be re-terminated in pedestal | MATTHEW | MATTHEW | | ES | R | 5009491 | MESA ELECTRIC, LLC. | ER | C | 06/30/2015 | | MATTHEW | MATTHEW | | ER | C | 4984165 | MESA ELECTRIC, LLC. | ER | R | 06/25/2015 | framing not done in unfinished basement for wall for stair light / outlet ------------- no mcc 10/3 to dryer 2 - 6/3 cu to a/c / range 6/3 al to sub panel in unfinished basement no cen vac | CRAIG | CRAIG | | ER | R | 4981227 | MICK HEATING & SHEET METAL CO. | H= | C | 08/28/2015 | CORRECTIONS MADE.. | LUKE | LUKE | | H= | C | 5024643 | MICK HEATING & SHEET METAL CO. | H= | P | 08/26/2015 | NEED GAS METER SET FOR FINAL, NEED TO COMPLETE DRAINS ON EQUIPMENT IN BASEMENT, A/C AND 90% FURNACE. REST OK.. NOTE: NO MANTEL, A/C COMPLETE, UNFINISHED BASEMENT, OUTSIDE AIR TO RETURN.. | LUKE | LUKE | | H= | P | 5022653 | MICK HEATING & SHEET METAL CO. | HC | C | 06/25/2015 | RELEASE METER | STEVEC | STEVEC | | HC | C | 4981139 | MICK HEATING & SHEET METAL CO. | HRR | C | 06/25/2015 | Note: duct design, equipment matches, outside air to return, AC rough, unfinished basement, water heater not set at this time check vent connections by final. | STEVEC | STEVEC | | HRR | C | 4981138 | AMERICAN PRIDE PLUMBING | HI | C | 06/11/2015 | 10 lb test ok. Note: 1 1/4" main. F, w/h, cook top, future bbq, f/p. | MARK | MARK | | HI | C | 4971549 | AMERICAN PRIDE PLUMBING | P= | C | 08/28/2015 | certificate of potable water to scanning | TED | TED | | P= | C | 5024092 | AMERICAN PRIDE PLUMBING | P= | P | 08/27/2015 | need certificate of potable water, rest ok, unfinished basement, no sprinkler stub | TED | TED | | P= | P | 5023623 | AMERICAN PRIDE PLUMBING | PWO | C | 06/16/2015 | | TIM | TIM | | PWO | C | 4974026 | AMERICAN PRIDE PLUMBING | PB | C | 06/12/2015 | correction made, horizontal dry vent ok this time, (clean out at wall ) | TED | TED | | PB | C | 4972421 | AMERICAN PRIDE PLUMBING | PTO | C | 06/12/2015 | correction made | TED | TED | | PTO | C | 4972417 | AMERICAN PRIDE PLUMBING | PTO | P | 06/11/2015 | need sewage ejector pit drain connected to 4'' run out of house | TED | TED | | PTO | P | 4971620 | AMERICAN PRIDE PLUMBING | PB | R | 06/11/2015 | sewage ejector drain to connect into 4'', horizontal dry vent on basement floor drain, note: basement drains run to sewage ejector pit, no water run under slab | TED | TED | | PB | R | 4971611 |
|
|