STAUFFER AND SONS CONSTRUCTION | B= | C | 09/02/2015 | | BOBF | BOBF | | B= | C | 5029245 |
STAUFFER AND SONS CONSTRUCTION | BLA | C | 07/06/2015 | | ED | ED | | BLA | C | 4987303 |
STAUFFER AND SONS CONSTRUCTION | BIN | C | 06/29/2015 | | DALE | DALE | | BIN | C | 4983141 |
STAUFFER AND SONS CONSTRUCTION | BFR | C | 06/29/2015 | eng. on file | DALE | DALE | | BFR | C | 4983137 |
STAUFFER AND SONS CONSTRUCTION | BFR | P | 06/26/2015 | need engineering for ledger in crawl space attached to foundation supporting floor (not on plans), add, ht20's at GT@, ST22 at girder GT2, re[lace 1 1/2 nails with 10 D at HUS 26 truss hangers at GT4 girder, missing nails at truss hanger TO9B truss, missing lateral bracing at T10,TO9,GT2trusses, ok to insulate | ED | ED | | BFR | P | 4981615 |
STAUFFER AND SONS CONSTRUCTION | BSP | P | 06/18/2015 | rear porch piers ok | ED | ED | | BSP | P | 4976299 |
STAUFFER AND SONS CONSTRUCTION | BFT | C | 06/18/2015 | | ED | ED | | BFT | C | 4976298 |
STAUFFER AND SONS CONSTRUCTION | BFN | C | 06/18/2015 | engineer inspection letter on file for footing, foundation design and soils on file, no drain required per soils engineer | ED | ED | | BFN | C | 4976288 |
STAUFFER AND SONS CONSTRUCTION | BFT | P | 05/13/2015 | AUTHORIZED INSPECTION BY ENGINEER | REBECCA | REBECCA | REBECCA | BFT | P | 4953448 |
STAUFFER AND SONS CONSTRUCTION | BFN | P | 05/13/2015 | AUTHORIZED INSPECTION BY ENGINEER | REBECCA | REBECCA | REBECCA | BFN | P | 4953447 |
ROWAN ELECTRIC LLC | E= | C | 08/18/2015 | a/c ok 30 amp | CRAIG | CRAIG | | E= | C | 5017429 |
ROWAN ELECTRIC LLC | ES | C | 08/18/2015 | Residential Underground: 200 amp 3/w new res seal meter | CRAIG | CRAIG | | ES | C | 5017421 |
ROWAN ELECTRIC LLC | EUG | C | 07/02/2015 | 3/W 4/0 AL SERVICE LATERAL | CRAIG | CRAIG | | EUG | C | 4985569 |
ROWAN ELECTRIC LLC | ES | R | 07/02/2015 | Residential Underground: REMOVE TEMP PANEL FROM PEDESTAL | CRAIG | CRAIG | | ES | R | 4985568 |
ROWAN ELECTRIC LLC | ER | C | 06/25/2015 | no mcc 3 - 10/3 to a/c / oven / dryer under cabinet outlets low volt cen vac crawl space | CRAIG | CRAIG | | ER | C | 4981088 |
BRUNO'S MECHANICAL INC. | H= | C | 09/01/2015 | Corrections made. | MICHAELS | MICHAELS | | H= | C | 5028200 |
BRUNO'S MECHANICAL INC. | H= | P | 08/31/2015 | Need medium pressure label on gas riser, mech room has been sheet rocked since rough and rock is against w/h vent, need w/h pan drain completed. Note: conditioned crawl space, high/low transfer in wall, full a/c, fp is wood burning. | MICHAELS | MICHAELS | | H= | P | 5026851 |
UNIQUE RADIANT HTG. & PLBG. | HO | C | 07/02/2015 | 60# test ok. 3/4" 2lb. poly from existing line to house. | MICHAELS | MICHAELS | | HO | C | 4986036 |
BRUNO'S MECHANICAL INC. | HC | C | 06/25/2015 | RELEASE METER | MARK | MARK | | HC | C | 4980315 |
BRUNO'S MECHANICAL INC. | HRR | C | 06/25/2015 | ALL OK. | MARK | MARK | | HRR | C | 4980305 |
BRUNO'S MECHANICAL INC. | HRR | P | 06/24/2015 | Need to re attach bath fan vent through roof. Rest ok. Note: Has a 60K sealed comb bryant with direct vent. Hi/Lo transfer grills to house from garage mech rm. At final mech rm doors must be self closing with seals. | MARK | MARK | | HRR | P | 4979702 |
UNIQUE RADIANT HTG. & PLBG. | HI | C | 06/17/2015 | 10 lb test ok. Note: Has 1 1/4" main. F, w/h, cook top, fut bbq. Will have meter at the street, reg at house and 2# system. Need 2# letter by final. | MARK | MARK | | HI | C | 4974749 |
UNIQUE RADIANT HTG. & PLBG. | PWO | C | 09/01/2015 | WATER LINE DEPTH VERIFIED , POTABLE WATER CERT TO SCANNING | GABE | GABE | | PWO | C | 5027970 |
UNIQUE RADIANT HTG. & PLBG. | P= | C | 09/01/2015 | NOTE : CRAWL SPACE , NO IRRIGATION . POTABLE WATER CERT TO SCANNING | GABE | GABE | | P= | C | 5027957 |
UNIQUE RADIANT HTG. & PLBG. | P16 | C | 09/01/2015 | Potable water test in images. | JACK | JACK | | P16 | C | 5027543 |
UNIQUE RADIANT HTG. & PLBG. | PWO | P | 07/02/2015 | NEED TO TIE INTO WELL , LEAVE TRENCH OPEN AT WELL | GABE | GABE | | PWO | P | 4985597 |
UNIQUE RADIANT HTG. & PLBG. | PTO | C | 06/17/2015 | NOTE : CRAWL SPACE , NO IRRIGATION , NEED PWO AND POTABLE WATER CERT BY FINAL | GABE | GABE | | PTO | C | 4975100 |