DDR-33 | B= | C | 09/23/2015 | | NATHAN | NATHAN | | B= | C | 5042988 |
DDR-33 | B= | P | 09/22/2015 | need address posted on home per previous comments / need less than 30" from porch surface to grade in all directions for acceptance of installed rail / freeze board at front cantilever. -- Schedule a new Building Final when above items are complete. | NATHAN | NATHAN | | B= | P | 5042018 |
DDR-33 | B= | R | 09/21/2015 | missing code compliant numeric address posted on structure / missing carbon alarm upper level / missing(1)egress ladder at basement window well / front porch guard has openings greater than 4" / penetrations around exterior and under rear cantilever / still need engineering letter of inspection addressing rear covered porch piers and need to complete corrections from BSP inspection dated 8/26/15 / unfinished basement / no rear deck | BRIANB | BRIANB | | B= | R | 5040988 |
DDR-33 | BSP | P | 08/26/2015 | rear patio not exposed for inspection remove section of ceiling for inspector / need post cap to beam connection / rear piers not inspected dig down next to 1 pier to the bottom and width of pier for inspection. Letter for beam post bearing required. | NATHAN | NATHAN | | BSP | P | 5023195 |
DDR-33 | BLA | C | 08/11/2015 | | JOHN | JOHN | | BLA | C | 5012430 |
DDR-33 | BFR | C | 08/11/2015 | | JOHN | JOHN | | BFR | C | 5012429 |
DDR-33 | BFR | P | 07/31/2015 | all frame items not corrected / 16" oc garage ceiling / foam and firestop // trip fee waived by JW 8/11 | NATHAN | NATHAN | | BFR | P | 5006034 |
DDR-33 | BIN | R | 07/31/2015 | not done | NATHAN | NATHAN | | BIN | R | 5006033 |
DDR-33 | BFR | P | 07/30/2015 | 16" oc garage ceiling / 24" oc stud max spacing at garage wall by monopost / 3/4 plywood at bottom of garage chase / fur down heat run for required R value / foam and firestop / point load rear kitchen window | NATHAN | NATHAN | | BFR | P | 5005093 |
DDR-33 | BFT | C | 06/22/2015 | all pads installed. | NATHAN | NATHAN | | BFT | C | 4978393 |
DDR-33 | BFD | C | 06/22/2015 | drain is habitable to sump / float 1.5" / final grade 10% to defined 2% swale | NATHAN | NATHAN | | BFD | C | 4978392 |
DDR-33 | BFN | C | 06/22/2015 | ALL PAPERWORK PICKED UP | NATHAN | NATHAN | | BFN | C | 4978391 |
DDR-33 | BFN | P | 06/11/2015 | missing pad at basement still, need all paperwork at drain, ufer is in, steel is okay. | NATHAN | NATHAN | | BFN | P | 4971998 |
DDR-33 | BFT | P | 06/01/2015 | -------------missing pad at center of basement will check at walls ------------- need openhole stating 2000 psf to match plan pour at own risk | NATHAN | NATHAN | | BFT | P | 4964589 |
ELECTRIC TECH INC. | E= | C | 09/21/2015 | | TOMC | TOMC | | E= | C | 5040145 |
ELECTRIC TECH INC. | E= | R | 09/16/2015 | need receptacle on kitchen stem facing living room , need dedicated ckt for sump pump ----- 30 amp a/c | TOMC | TOMC | | E= | R | 5037961 |
ELECTRIC TECH INC. | E= | R | 09/15/2015 | not ready | TOMC | TOMC | | E= | R | 5036891 |
ELECTRIC TECH INC. | ES | C | 07/30/2015 | Residential Underground: 150 AMP 3/W NEW RES. NEEDS METER SEAL | TIMA | TIMA | | ES | C | 5004790 |
ELECTRIC TECH INC. | ER | C | 07/30/2015 | 1-20 1-15 #6 AL---NO VAC----UNFINISHED BASEMENT--- | TIMA | TIMA | | ER | C | 5004789 |
ELECTRIC TECH INC. | EUG | C | 07/30/2015 | | TIMA | TIMA | | EUG | C | 5004784 |
ELECTRIC TECH INC. | ER | R | 07/24/2015 | WIRE IN AIR RETURN AT KITCHEN ISLAND,STAPLE WIRE AT KITCHEN ISLAND RECEPT BOX,NEED TO BOX OUT FOR WIRES AT SUPPORT BEAM IN LOWER LIVING ROOM,NEED RECEPT 6' FROM CORNER ON BATH WALL FACING INTO LOWER LIVING ROOM( ONE IN HALL DOESNT COUNT) | TIMA | TIMA | | ER | R | 5000822 |
GLASER ENERGY GROUP INC. | HO | C | 09/14/2015 | test ok | DICK | DICK | | HO | C | 5035026 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | H= | C | 09/11/2015 | unfinished basement 2 SA ! RA A/C complete. | DICK | DICK | | H= | C | 5034765 |
WHITE BROS CUSTOM PLUMBING & HEATING | HI | C | 08/05/2015 | 10 LB TEST OK NOTE 1 " LINE 1 FURN,W/H STILL NEED HO INSPECTION | DAVIDH | DAVIDH | | HI | C | 5008277 |
ENVIRONMENTAL HEATING & AIR CONDITIONING INC. | HRR | C | 07/27/2015 | A/C ROUGH 6" OSA | DAVIDH | DAVIDH | | HRR | C | 5001143 |
DMB PLUMBING SERVICES INC. | P= | C | 09/17/2015 | UNFINISHED BASEMENT | DICK | DICK | | P= | C | 5038446 |
DMB PLUMBING SERVICES INC. | PTO | C | 07/23/2015 | unfinished basement, note- check water heater and ejector tie in's at final. | TAYLOR | TAYLOR | | PTO | C | 4999387 |
DMB PLUMBING SERVICES INC. | PB | C | 06/29/2015 | corrections made. | TAYLOR | TAYLOR | | PB | C | 4982691 |
DMB PLUMBING SERVICES INC. | PB | P | 06/26/2015 | ejector needs to connect to 4 inch vertically, incorrect vented floor drain. | TAYLOR | TAYLOR | | PB | P | 4981664 |