HOMEOWNER | B= | C | 06/03/2016 | All other required Final inspections are complete. (This is a computer generated result) | DALE | DALE | | B= | C | 5214099 |
HOMEOWNER | B= | P | 05/31/2016 | finished basement, deck in. Additional Inspections Required (computer generated): External Agency Inspection HD= by HEALTHDEPT is not Completed yet. | DALE | DALE | | B= | P | 5211367 |
HOMEOWNER | BSP | P | 05/26/2016 | front porch ok | SCOTTS | SCOTTS | | BSP | P | 5209618 |
HOMEOWNER | BLA | C | 02/10/2016 | | DANE | DANE | | BLA | C | 5131812 |
HOMEOWNER | BTR | C | 11/25/2015 | | DALE | DALE | | BTR | C | 5087518 |
HOMEOWNER | BFR | C | 11/19/2015 | | BOBF | BOBF | | BFR | C | 5082779 |
HOMEOWNER | BIN | C | 11/19/2015 | | BOBF | BOBF | | BIN | C | 5082778 |
HOMEOWNER | BFR | R | 11/16/2015 | garage narrow wall requires nails, not nailed per plan / missing H 2.5 at E-1 and B-1 / fire block fire place chase / missing laterals at A-13 and A-1 / complete hardware at floor under front porch / metal shims at steel beams / carry point loads to headers in basement / eng letter for porch on file / okay to insulate | BOBF | BOBF | | BFR | R | 5080663 |
HOMEOWNER | BSP | P | 08/28/2015 | west end deck and posts ok / east end post bases except middle post ok | DALE | DALE | | BSP | P | 5025230 |
HOMEOWNER | BSP | P | 07/17/2015 | rear deck piers ok | DALE | DALE | | BSP | P | 4995881 |
HOMEOWNER | BFI | C | 06/22/2015 | | DALE | DALE | | BFI | C | 4978159 |
HOMEOWNER | BFN | C | 06/22/2015 | ok per eng. / all paperwork on file / float | DALE | DALE | | BFN | C | 4978157 |
HOMEOWNER | BFT | C | 06/22/2015 | ok per eng. | DALE | DALE | | BFT | C | 4978156 |
HOMEOWNER | BFD | C | 06/22/2015 | | DALE | DALE | | BFD | C | 4978122 |
DUKES ELECTRIC, INC | E= | C | 05/23/2016 | | CRAIG | CRAIG | | E= | C | 5206117 |
DUKES ELECTRIC, INC | EP | C | 05/19/2016 | 200 amp and 100 amp both sub panels ok | CRAIG | CRAIG | | EP | C | 5204028 |
DUKES ELECTRIC, INC | E= | R | 05/19/2016 | install arc shield in master bath ---------- missing outlet in basement bedroom by wet bar ---------- no power other bedroom ---------- gfi nook outlets ------------- a/c per wire | CRAIG | CRAIG | | E= | R | 5204027 |
DUKES ELECTRIC, INC | ES | C | 12/08/2015 | Residential Underground: 200 amp 3/w new res seal meter | CRAIG | CRAIG | | ES | C | 5094498 |
DUKES ELECTRIC, INC | ES | R | 12/07/2015 | Residential Underground: can' t find ufer to verify connection ------------ note 4/w 4/0 al is installed in insulation to sub in basement ----------- 200 amp 3/w on side of house | CRAIG | CRAIG | | ES | R | 5093452 |
DUKES ELECTRIC, INC | ER | C | 11/04/2015 | | MATTHEW | MATTHEW | | ER | C | 5072809 |
DUKES ELECTRIC, INC | ER | R | 11/03/2015 | install porch outlet by bedroom on main level facing west ----------------- 4/w 1/0 al to sub panel on main level no mccc 10/3 to dryer 6/3 cu to oven 4/w 4/0 al to sub panel in finished basement no mcc 10/3 to well 8/3 cu to range 6/3 al tp a/c no cen vac | CRAIG | CRAIG | | ER | R | 5071969 |
MILLER HEATING & AIR CONDITIONING, INC. | H= | C | 05/25/2016 | Final ok. Note: Finished basement, hi/lo grilla, no a/c condenser, 6" osa. no mantle on lower level. 2- direct vent furnaces. | MARK | MARK | | H= | C | 5207838 |
MILLER HEATING & AIR CONDITIONING, INC. | HC | C | 11/13/2015 | RELEASE METER | JEFFL | JEFFL | | HC | C | 5079192 |
MILLER HEATING & AIR CONDITIONING, INC. | HRR | C | 11/13/2015 | Corrections made. | JEFFL | JEFFL | | HRR | C | 5079185 |
MILLER HEATING & AIR CONDITIONING, INC. | HRR | P | 11/12/2015 | Need to seal elec wires through return B/R 4, ins shield for f/p mn lvl, rest looks good. Note: Fin. bsmnt, has 1- a/c coil and line set rough, 1- OSA to return, equip matches 100K and 60K . | MARK | MARK | | HRR | P | 5077574 |
SPRINGS GAS, INC. | HI | C | 10/28/2015 | 10 lb test ok. Will fit with meter at house or med pressure with reg at house. 1 1/4" main. 2- f/p, 2- w/h, 2- furn, cook top. | MARK | MARK | | HI | C | 5067986 |
UNIQUE RADIANT HTG. & PLBG. | P= | C | 05/19/2016 | POTABLE WATER CERT TO SCANNING | GABE | GABE | | P= | C | 5203132 |
UNIQUE RADIANT HTG. & PLBG. | P= | P | 04/29/2016 | NEED POTABLE WATER CERT TO COMPLETE , NOTE : FINISHED BASEMENT , RP INSTALLED IN MEC , AAV AT BAR | GABE | GABE | | P= | P | 5188147 |
UNIQUE RADIANT HTG. & PLBG. | PTO | C | 10/21/2015 | NOTE : FINISHED BASEMENT , COMBO WASTE AND VENT AT BAR , IRRIGATION STUB | GABE | GABE | | PTO | C | 5062883 |
HOMEOWNER | PWO | C | 10/19/2015 | POTABLE WATER CERT BY FINAL | GABE | GABE | | PWO | C | 5060741 |
UNIQUE RADIANT HTG. & PLBG. | PB | C | 06/30/2015 | NO WATER IN . | GABE | GABE | | PB | C | 4983993 |