GOEBEL CONSTRUCTION, INC | B= | C | 11/19/2015 | | BOBF | BOBF | | B= | C | 5082750 |
GOEBEL CONSTRUCTION, INC | BLA | C | 09/18/2015 | | DALE | DALE | | BLA | C | 5039825 |
GOEBEL CONSTRUCTION, INC | BFR | C | 09/14/2015 | eng letter to allow for non floating interior walls on file | BOBF | BOBF | | BFR | C | 5035913 |
GOEBEL CONSTRUCTION, INC | BIN | C | 09/14/2015 | | BOBF | BOBF | | BIN | C | 5035910 |
GOEBEL CONSTRUCTION, INC | BSP | T | 09/11/2015 | PAID (REC#1286548) PLAN SPLICE FEE: $50 by: MICHAELA for Construction: Add garage service door | MICHAELA | MICHAELA | | BSP | T | 5034344 |
GOEBEL CONSTRUCTION, INC | BFR | R | 09/10/2015 | provide eng letter to allow for interior walls to be direct bearing ( non floating ) / missing MTS 12 at T05 and T06 / install LUS 24's at M01 and M02 trusses / revise plans to show garage service door / okay to insulate | BOBF | BOBF | | BFR | R | 5033965 |
GOEBEL CONSTRUCTION, INC | BSP | P | 08/19/2015 | porch frames and posts ok | DALE | DALE | | BSP | P | 5017941 |
GOEBEL CONSTRUCTION, INC | BSP | P | 07/27/2015 | 1 - 24" pier okay 1 30" pad okay | BOBF | BOBF | | BSP | P | 5001884 |
GOEBEL CONSTRUCTION, INC | BFI | C | 07/14/2015 | R 10 at foundation wall for slab on grade | ED | ED | | BFI | C | 4993132 |
GOEBEL CONSTRUCTION, INC | BFT | C | 07/14/2015 | | ED | ED | | BFT | C | 4993129 |
GOEBEL CONSTRUCTION, INC | BFN | C | 07/14/2015 | | ED | ED | | BFN | C | 4993128 |
GOEBEL CONSTRUCTION, INC | BFD | C | 07/14/2015 | engineer inspection letter for footing, foundation, soils and foundation design on file, no drain required per soils | ED | ED | | BFD | C | 4993127 |
GOEBEL CONSTRUCTION, INC | BFT | P | 07/02/2015 | AUTHORIZED INSPECTION BY ENGINEER | MINDY | MINDY | MINDY | BFT | P | 4985901 |
GOEBEL CONSTRUCTION, INC | BFN | P | 07/02/2015 | AUTHORIZED INSPECTION BY ENGINEER | MINDY | MINDY | MINDY | BFN | P | 4985900 |
MESA ELECTRIC, LLC. | E= | C | 10/30/2015 | | CRAIG | CRAIG | | E= | C | 5069749 |
MESA ELECTRIC, LLC. | E= | R | 10/26/2015 | still need island countertop installed to check overhang | MATTHEW | MATTHEW | | E= | R | 5065426 |
MESA ELECTRIC, LLC. | E= | R | 10/23/2015 | gfi all outlets within 6' of wet bar sink ------------- master bath outlets not gfi ----------- j-box in master closet ???? -------------- install island counter top --------- no ac or rough | CRAIG | CRAIG | | E= | R | 5064421 |
MESA ELECTRIC, LLC. | ER | C | 09/04/2015 | | MATTHEW | MATTHEW | | ER | C | 5030829 |
MESA ELECTRIC, LLC. | ES | C | 09/03/2015 | Residential Underground: 200 amp 3/w new res seal meter note ufer corner of garage south east | CRAIG | CRAIG | | ES | C | 5030123 |
MESA ELECTRIC, LLC. | ER | R | 09/03/2015 | install uf cable in conduit to kitchen island ( 340.12 ) ----------no mcc 3 - 10/3 2 - 6/3 cu no cen vac | CRAIG | CRAIG | | ER | R | 5030121 |
MESA ELECTRIC, LLC. | EUG | C | 08/06/2015 | service lateral from pedestal to home | MATTHEW | MATTHEW | | EUG | C | 5009422 |
MESA ELECTRIC, LLC. | EUG | P | 07/20/2015 | well wire on north side of foundation | TOMC | TOMC | | EUG | P | 4996101 |
AMERICAN PRIDE PLUMBING | H= | C | 10/30/2015 | Final ok. Note: Sealed comb boiler and louver door | MARK | MARK | | H= | C | 5069233 |
MICK HEATING & SHEET METAL CO. | H= | C | 10/30/2015 | Final ok. Note: Sealed comb boiler and louver door. No a/c. | MARK | MARK | | H= | C | 5069226 |
AMERICAN PRIDE PLUMBING | HC | C | 09/04/2015 | RELEASE METER. OK TO RELEASE METER | GABE | GABE | | HC | C | 5030842 |
AMERICAN PRIDE PLUMBING | HI | C | 09/04/2015 | 10 # TEST OK | GABE | GABE | | HI | C | 5030840 |
AMERICAN PRIDE PLUMBING | HI | P | 09/03/2015 | LOST TEST. 1 1/4'' MAIN, BOILER, FIREPLACE, FUTURE 3/4'' GARAGE, RANGE, BBQ.. | LUKE | LUKE | | HI | P | 5029804 |
MICK HEATING & SHEET METAL CO. | HRR | C | 09/03/2015 | FIREPLACE AND VENT GOOD, TWO DRYERS, ALL EXHAUST FANS AND DUCT OK, DIRECT VENT BOILER VENT PIPES GOOD. | LUKE | LUKE | | HRR | C | 5029796 |
AMERICAN PRIDE PLUMBING | HWP | P | 08/03/2015 | Whole house under 60#, ok. Ok to cover. | MARK | MARK | | HWP | P | 5006322 |
DAVIS GAS SHOP INC | HO | C | 07/17/2015 | 10 lb test on 1 1/4" PE from house underground to meter is ok. Note: 1 1/4" PE was existing, only replaced riser due to fire. | MARK | MARK | | HO | C | 4995406 |
AMERICAN PRIDE PLUMBING | P= | C | 11/10/2015 | SLAB ON GRADE , ROUGH ONLY FOR BATH ROOM AT LAUNDRY , NO IRRIGATION . POTABLE WATER CERT TO SCANNING | GABE | GABE | | P= | C | 5076567 |
AMERICAN PRIDE PLUMBING | P= | R | 10/30/2015 | not ready reinspect all, need certificate of potable water also | TED | TED | | P= | R | 5069090 |
AMERICAN PRIDE PLUMBING | PTO | C | 09/09/2015 | CORRECTIONS MADE | GABE | GABE | | PTO | C | 5032969 |
AMERICAN PRIDE PLUMBING | PTO | T | 09/08/2015 | PAID (REC#1285765) still low test at laundry and north bathroom. | TAYLOR | TAYLOR | | PTO | T | 5031671 |
AMERICAN PRIDE PLUMBING | PTO | P | 09/04/2015 | LOST TEST AT LAUNDRY LAV , AND MASTER , WATER OK REST DWV OK , SLAB ON GRADE | GABE | GABE | | PTO | P | 5030837 |
AMERICAN PRIDE PLUMBING | PTO | R | 09/03/2015 | low test dwv in laundry room next to garage and on bathroom north side of house, note: slab on grade | TED | TED | | PTO | R | 5029808 |
AMERICAN PRIDE PLUMBING | PTO | P | 07/31/2015 | WATER LINES UNDER SLAB TO FIXTURES OK , GOOD TO POUR | GABE | GABE | | PTO | P | 5005510 |
AMERICAN PRIDE PLUMBING | PB | C | 07/31/2015 | WATER LINE STUBBED UP IN MEC | GABE | GABE | | PB | C | 5005509 |
AMERICAN PRIDE PLUMBING | PB | P | 07/27/2015 | H20 RUN UNDER FOOTER | GABE | GABE | | PB | P | 5001399 |
AMERICAN PRIDE PLUMBING | PWO | C | 07/17/2015 | NEED POTABLE WATER CERT BY FINAL | GABE | GABE | | PWO | C | 4995682 |