ROBERT SCOTT GENERAL CONTRACTORS, INC. | B= | C | 12/28/2015 | Unfinished basement | NICK | NICK | | B= | C | 5105928 |
ROBERT SCOTT GENERAL CONTRACTORS, INC. | BLA | C | 10/23/2015 | item corrected | DANE | DANE | | BLA | C | 5064329 |
ROBERT SCOTT GENERAL CONTRACTORS, INC. | BLA | P | 10/22/2015 | weep screed at front porch must be above the concrete stoop / rest of house lath OK | DANE | DANE | | BLA | P | 5063278 |
ROBERT SCOTT GENERAL CONTRACTORS, INC. | BSP | P | 10/22/2015 | deck frame and posts OK | DANE | DANE | | BSP | P | 5063266 |
ROBERT SCOTT GENERAL CONTRACTORS, INC. | BIN | C | 10/19/2015 | | DANE | DANE | | BIN | C | 5060614 |
ROBERT SCOTT GENERAL CONTRACTORS, INC. | BFR | C | 10/14/2015 | items corrected | DANE | DANE | | BFR | C | 5057754 |
ROBERT SCOTT GENERAL CONTRACTORS, INC. | BFR | P | 10/13/2015 | OK to insulate (leave point loads exposed) / fire block garage door brackets / missing stabilizer braces in trusses on upper floor / plans call 2 trimmers at EE of all headers at bearing wall / need connection for 3 ML at stairs to upper floor / both landings need to be strapped to floor above / remove float blocks / missing PL for girder through main floor to foundation / remove wood shims at beam pockets and replace with metal shims and glue | DANE | DANE | | BFR | P | 5056464 |
ROBERT SCOTT GENERAL CONTRACTORS, INC. | BSP | P | 10/12/2015 | 4 piers OK for rear deck | DANE | DANE | | BSP | P | 5055437 |
ROBERT SCOTT GENERAL CONTRACTORS, INC. | BSP | R | 10/08/2015 | all piers are only 27" to 24" and need min. 30" | DANE | DANE | | BSP | R | 5053565 |
ROBERT SCOTT GENERAL CONTRACTORS, INC. | BFD | C | 08/18/2015 | usable drain OK | DANE | DANE | | BFD | C | 5017149 |
ROBERT SCOTT GENERAL CONTRACTORS, INC. | BFN | C | 08/03/2015 | design on file / open hole on file / soils report on file / usable drail / 1500 PSF / eufer OK / 10% grade | DANE | DANE | | BFN | C | 5006838 |
ROBERT SCOTT GENERAL CONTRACTORS, INC. | BFT | C | 07/29/2015 | footing OK including interior pads | DANE | DANE | | BFT | C | 5003489 |
ROBERT SCOTT GENERAL CONTRACTORS, INC. | BFT | P | 07/10/2015 | AUTHORIZED INSPECTION BY ENGINEER | BPHILLIPS | BPHILLIPS | BPHILLIPS | BFT | P | 4991090 |
ROBERT SCOTT GENERAL CONTRACTORS, INC. | BFN | P | 07/10/2015 | AUTHORIZED INSPECTION BY ENGINEER | BPHILLIPS | BPHILLIPS | BPHILLIPS | BFN | P | 4991089 |
SERVICE FIRST ELECTRIC | E= | C | 12/16/2015 | NOTES---AC PRE WIRE | BRIAN | BRIAN | | E= | C | 5099905 |
SERVICE FIRST ELECTRIC | E= | R | 12/15/2015 | locked 2:35 | BRET | BRET | | E= | R | 5099421 |
SERVICE FIRST ELECTRIC | ES | C | 10/12/2015 | Residential Underground: NEW 150 AMP SERVICE | MIKEC | MIKEC | | ES | C | 5055724 |
SERVICE FIRST ELECTRIC | ER | C | 10/12/2015 | UNFINISHED BASEMENT,NO CEN. VAC | MIKEC | MIKEC | | ER | C | 5055722 |
GENE'S HEATING AND AIR LLC | H= | C | 12/11/2015 | | STEVEC | STEVEC | | H= | C | 5097475 |
GENE'S HEATING AND AIR LLC | HC | C | 10/09/2015 | RELEASE METER | STEVEC | STEVEC | | HC | C | 5054503 |
GENE'S HEATING AND AIR LLC | HRR | C | 10/09/2015 | Corrections made. | STEVEC | STEVEC | | HRR | C | 5054502 |
GENE'S HEATING AND AIR LLC | HRR | P | 10/08/2015 | Vent lacks clearance from framing/chase in garage. Note: duct design, unfinished basement, outside air to return, line-set only, equipment matches. | STEVEC | STEVEC | | HRR | P | 5053601 |
KAMPP-L ENTERPRISES, INC. | HI | C | 09/30/2015 | 10# test o.k. 1"1/4 main, furnace, water heater, 2-bbq, range. | STEVEC | STEVEC | | HI | C | 5047973 |
KAMPP-L ENTERPRISES, INC. | P= | C | 12/24/2015 | NO IRRIGATION | JOEL | JOEL | | P= | C | 5105694 |
KAMPP-L ENTERPRISES, INC. | PTO | C | 09/25/2015 | unfinished basement. | TAYLOR | TAYLOR | | PTO | C | 5044291 |
KAMPP-L ENTERPRISES, INC. | PB | C | 08/21/2015 | | DICK | DICK | | PB | C | 5019811 |