ROBERT SCOTT GENERAL CONTRACTORS, INC. | B= | C | 04/15/2016 | corrections completed | ERICR | ERICR | | B= | C | 5178479 |
ROBERT SCOTT GENERAL CONTRACTORS, INC. | B= | P | 04/08/2016 | need 18" landing outside slider per RBC 303.4.16 / need blown insulation certificate -- Schedule a new Building Final when above items are complete. | ERICR | ERICR | | B= | P | 5173309 |
ROBERT SCOTT GENERAL CONTRACTORS, INC. | BFR | C | 12/24/2015 | engineer letter received for balloon wall and ST22 strap // all other items corrected | LINDSEY | LINDSEY | | BFR | C | 5105543 |
ROBERT SCOTT GENERAL CONTRACTORS, INC. | BIN | C | 12/24/2015 | | LINDSEY | LINDSEY | | BIN | C | 5105542 |
ROBERT SCOTT GENERAL CONTRACTORS, INC. | BFR | P | 12/21/2015 | missing (2) 2x for post under A12 truss at top of stairs / foam & fire stop / damaged hangar for A04 truss over the mbr door / missing ST22 strap to k.s. studs centered on to rim board below per plan note A at rear wall / ballon wall not framed per plan to bottom of rafters in family room / okay to insulate / unfinished basement / no deck | BRIANB | BRIANB | | BFR | P | 5103181 |
ROBERT SCOTT GENERAL CONTRACTORS, INC. | BLA | C | 12/10/2015 | Repairs to lath at front garage wall okay | BRIANB | BRIANB | | BLA | C | 5096489 |
ROBERT SCOTT GENERAL CONTRACTORS, INC. | BSP | P | 12/08/2015 | Portal wall OK / Front porch lid OK, still need to see post | NICK | NICK | | BSP | P | 5093970 |
ROBERT SCOTT GENERAL CONTRACTORS, INC. | BLA | R | 12/04/2015 | lath okay / however, garage portal wall has been covered and not inspected | BRIANB | BRIANB | | BLA | R | 5092257 |
ROBERT SCOTT GENERAL CONTRACTORS, INC. | BFD | C | 09/22/2015 | usable drain OK / sump in right rear | DANE | DANE | | BFD | C | 5041526 |
ROBERT SCOTT GENERAL CONTRACTORS, INC. | BFN | C | 09/22/2015 | engineer observation report on file / open hole on file / foundation design on file / Eufer noted / usable drain | DANE | DANE | | BFN | C | 5041521 |
ROBERT SCOTT GENERAL CONTRACTORS, INC. | BFD | R | 09/21/2015 | no paperwork on site / need open hole, engineer foundation inspection observation, and foundation design / usable drain installed to sump in right rear corner | DANE | DANE | | BFD | R | 5040538 |
ROBERT SCOTT GENERAL CONTRACTORS, INC. | BFN | P | 09/14/2015 | OK to use engineer for foundation inspection | DANE | DANE | | BFN | P | 5035541 |
ROBERT SCOTT GENERAL CONTRACTORS, INC. | BFT | C | 09/10/2015 | footing OK including interior pads | LINDSEY | LINDSEY | | BFT | C | 5033466 |
SERVICE FIRST ELECTRIC | E= | C | 03/01/2016 | note: a/c prewire | BRET | BRET | | E= | C | 5145832 |
SERVICE FIRST ELECTRIC | ES | C | 12/16/2015 | Residential Underground: 150 AMP 3-W NEWRES---OK TO SET METER----- | BRIAN | BRIAN | | ES | C | 5099884 |
SERVICE FIRST ELECTRIC | ER | C | 12/16/2015 | | BRIAN | BRIAN | | ER | C | 5099881 |
SERVICE FIRST ELECTRIC | ES | R | 12/15/2015 | install panel cover , framing not complete- framing must be done to protect cables lower garage wall | BRET | BRET | | ES | R | 5099451 |
SERVICE FIRST ELECTRIC | ER | P | 12/15/2015 | #6 al to range, unfinished basement , no mcc,no vac. | BRET | BRET | | ER | P | 5099442 |
GENE'S HEATING AND AIR LLC | H= | C | 03/01/2016 | THE PERFORMANCE TEST HAS BEEN RECEIVED. | JEFFB | JEFFB | | H= | C | 5144880 |
GENE'S HEATING AND AIR LLC | H= | P | 02/29/2016 | COULD NOT LOCATE THE PERFORMANCE TEST. NOTES: OUTSIDE AIR TO THE RETURN DUCT AND THE BASEMENT IS CONDITIONED. | JEFFB | JEFFB | | H= | P | 5144214 |
GENE'S HEATING AND AIR LLC | HRR | C | 12/18/2015 | Corrections made. | STEVEC | STEVEC | | HRR | C | 5101895 |
GENE'S HEATING AND AIR LLC | HRR | P | 12/17/2015 | See prior notes on B-vent clearances, venting. Trip fee waved this time only. | STEVEC | STEVEC | | HRR | P | 5100974 |
GENE'S HEATING AND AIR LLC | HRR | P | 12/16/2015 | B-vent lacks clearance from sub-floor main. Bath fan upper pushed down at roof line, re-secure. Note: provide performance test by final, equipment splice on file, line-set prep only, unfinished basement, rest o.k. | STEVEC | STEVEC | | HRR | P | 5100283 |
KAMPP-L ENTERPRISES, INC. | HC | C | 12/11/2015 | RELEASE METER | STEVEC | STEVEC | | HC | C | 5097459 |
KAMPP-L ENTERPRISES, INC. | HI | C | 12/11/2015 | 10# test o.k. 1"1/4 main, furnace, water heater, range, outdoor bbq. | STEVEC | STEVEC | | HI | C | 5097444 |
KAMPP-L ENTERPRISES, INC. | P= | C | 04/07/2016 | no irrigation, basement finish on different permit. | TAYLOR | TAYLOR | | P= | C | 5172113 |
KAMPP-L ENTERPRISES, INC. | PTO | C | 12/08/2015 | corrections made, note: vents through roof. | TAYLOR | TAYLOR | | PTO | C | 5093859 |
KAMPP-L ENTERPRISES, INC. | PTO | P | 12/07/2015 | need 3 inch and 4 inch long turn 90's horizontal to horizontal in basement, low test dwv at powder bath, rest ok, unfinished basement. | TAYLOR | TAYLOR | | PTO | P | 5092905 |
KAMPP-L ENTERPRISES, INC. | PB | C | 10/01/2015 | | TAYLOR | TAYLOR | | PB | C | 5048566 |