ASPEN GOLD GENERAL CONTRACTING & ENGINEERING, LLC | B= | C | 12/23/2015 | All other required Final inspections are complete. (This is a computer generated result) | DAN | DAN | | B= | C | 5105194 |
ASPEN GOLD GENERAL CONTRACTING & ENGINEERING, LLC | B= | P | 12/22/2015 | conditioned craw space. Additional Inspections Required (computer generated): External Agency Inspection N= by ENGINEERING is not Completed yet (Contact: City Engineering Inspections 719-385-5977). | DAN | DAN | | B= | P | 5103872 |
ASPEN GOLD GENERAL CONTRACTING & ENGINEERING, LLC | BLA | C | 11/03/2015 | | DANE | DANE | | BLA | C | 5071416 |
ASPEN GOLD GENERAL CONTRACTING & ENGINEERING, LLC | BIN | C | 10/22/2015 | all wall insulation is OK / crawl space vapor retarder must be sealed to foundation and all pads by final | DANE | DANE | | BIN | C | 5063212 |
ASPEN GOLD GENERAL CONTRACTING & ENGINEERING, LLC | BFR | C | 10/20/2015 | | DANE | DANE | | BFR | C | 5061570 |
ASPEN GOLD GENERAL CONTRACTING & ENGINEERING, LLC | BSP | P | 10/05/2015 | trusses and hardware above mech room OK and walls at mech room OK - note no MEP installed yet | DANE | DANE | | BSP | P | 5050754 |
ASPEN GOLD GENERAL CONTRACTING & ENGINEERING, LLC | BSP | P | 09/18/2015 | front lid ok // rear - add (1) h2.5t at truss C02-C10. Can check at frame / ok to install soffit | LINDSEY | LINDSEY | | BSP | P | 5039376 |
ASPEN GOLD GENERAL CONTRACTING & ENGINEERING, LLC | BFD | C | 08/24/2015 | craw space drain exterior except garage and front porch. Daylight drain rear center. | DAN | DAN | | BFD | C | 5020864 |
ASPEN GOLD GENERAL CONTRACTING & ENGINEERING, LLC | BFN | C | 08/17/2015 | Open hole and design on file / 1000 PSF / no drain required / Eufer installed on right side of garage wall | DANE | DANE | | BFN | C | 5016167 |
ASPEN GOLD GENERAL CONTRACTING & ENGINEERING, LLC | BFT | C | 08/07/2015 | footing OK including interior pads | DANE | DANE | | BFT | C | 5010337 |
ASPEN GOLD GENERAL CONTRACTING & ENGINEERING, LLC | BFT | R | 08/06/2015 | not ready / no rebar in any of the forms yet | DANE | DANE | | BFT | R | 5009323 |
SOUTHERN COLORADO ELECTRIC INC. | E= | C | 12/14/2015 | 30 AMP A.C | MIKEC | MIKEC | | E= | C | 5098538 |
SOUTHERN COLORADO ELECTRIC INC. | ES | C | 10/15/2015 | Residential Underground: NEW 200 AMP SERVICE | MIKEC | MIKEC | | ES | C | 5058321 |
SOUTHERN COLORADO ELECTRIC INC. | ER | C | 10/15/2015 | | MIKEC | MIKEC | | ER | C | 5058315 |
BROWN'S HEATING & COOLING, INC | H= | C | 12/21/2015 | Report received. | STEVEC | STEVEC | | H= | C | 5102373 |
BROWN'S HEATING & COOLING, INC | H= | P | 12/15/2015 | Pending duct leakage report. Note: performance test received. | STEVEC | STEVEC | | H= | P | 5099522 |
BROWN'S HEATING & COOLING, INC | H= | P | 12/07/2015 | B-vent lacks 1" clearance at sheet rock in mech, provide duct leakage report and performance test. Note: A/C complete rest o.k. | STEVEC | STEVEC | | H= | P | 5093388 |
BROWN'S HEATING & COOLING, INC | HC | C | 10/16/2015 | RELEASE METER | STEVEC | STEVEC | | HC | C | 5059417 |
BROWN'S HEATING & COOLING, INC | HRR | C | 10/16/2015 | Note: provide duct leakage report, performance test and equipment certificate by final. Conditioned crawl, direct vent furnace, A/C line-set and coil. | STEVEC | STEVEC | | HRR | C | 5059413 |
L & L GAS SHOP, LLC. | HI | C | 10/15/2015 | 10# test o.k. 1"1/4 main, furnace, 2-water heaters, range and 200k back up generator. | STEVEC | STEVEC | | HI | C | 5058459 |
TEAM PLUMBING, INC. | P= | C | 12/16/2015 | 3/4'' pvb installed, crawlspace | TED | TED | | P= | C | 5100341 |
TEAM PLUMBING, INC. | PTO | C | 10/19/2015 | corrections made. | TAYLOR | TAYLOR | | PTO | C | 5060442 |
TEAM PLUMBING, INC. | PTO | P | 10/16/2015 | leak at 3x2 wye going to laundry sink/floor drain, undersized wet vent for laundry sink, rest ok, note- crawl space. | TAYLOR | TAYLOR | | PTO | P | 5059388 |