ROBERT SCOTT GENERAL CONTRACTORS, INC. | B= | C | 04/15/2016 | corrections completed / No AC Unit | ERICR | ERICR | | B= | C | 5178475 |
ROBERT SCOTT GENERAL CONTRACTORS, INC. | B= | P | 04/08/2016 | Need to have an 18" landing out side sliding door per RBC 303.4.16 / need insulation cert for blown insulation -- Schedule a new Building Final when above items are complete. Additional Inspections Required (computer generated): External Agency Inspection F= by FIREDEPT is not Completed yet (Contact: 385-5982, x2). | ERICR | ERICR | | B= | P | 5173301 |
ROBERT SCOTT GENERAL CONTRACTORS, INC. | BFR | C | 01/22/2016 | items corrected | LINDSEY | LINDSEY | | BFR | C | 5121414 |
ROBERT SCOTT GENERAL CONTRACTORS, INC. | BIN | C | 01/22/2016 | | LINDSEY | LINDSEY | | BIN | C | 5121413 |
ROBERT SCOTT GENERAL CONTRACTORS, INC. | BFR | P | 01/19/2016 | OK to insulate; 1) Missing restraint on truss lateral bracing grater then 20' and ends. 2) "B" and "G" trusses missing clips at center bearing. 3) straps in master bedroom plumbing wall studs and top plate. 4) Splice to move garage service door to another wall. 5) Larger copy of fix for front porch fix. 6) Joist fix at furnace. | DAN | DAN | | BFR | P | 5118393 |
ROBERT SCOTT GENERAL CONTRACTORS, INC. | BLA | C | 01/12/2016 | | DAN | DAN | | BLA | C | 5114418 |
ROBERT SCOTT GENERAL CONTRACTORS, INC. | BFD | C | 11/02/2015 | Usable drain OK - drains into sump pit at left front corner of basement / foundation design received / open hole and soils report received / 2400 PSF / 5% grade / usable drain | DANE | DANE | | BFD | C | 5070426 |
ROBERT SCOTT GENERAL CONTRACTORS, INC. | BFN | C | 10/19/2015 | foundation reinforcement OK / need design and open hole at drain / Eufer installed on west garage wall | DANE | DANE | | BFN | C | 5060608 |
ROBERT SCOTT GENERAL CONTRACTORS, INC. | BFT | C | 10/15/2015 | footing and interior pads OK | DANE | DANE | | BFT | C | 5058457 |
ROBERT SCOTT GENERAL CONTRACTORS, INC. | BFT | P | 08/17/2015 | AUTHORIZED INSPECTION BY ENGINEER | MINDY | MINDY | MINDY | BFT | P | 5016281 |
ROBERT SCOTT GENERAL CONTRACTORS, INC. | BFN | P | 08/17/2015 | AUTHORIZED INSPECTION BY ENGINEER | MINDY | MINDY | MINDY | BFN | P | 5016280 |
SERVICE FIRST ELECTRIC | E= | C | 03/03/2016 | | BRET | BRET | | E= | C | 5147487 |
SERVICE FIRST ELECTRIC | E= | R | 03/02/2016 | arc-fault microwave circuit, gfci protect bedroom receptacle within 6' of bath sink, indicating light for garage door opener receptacle. front porch not working. install all screws in panel cover | BRET | BRET | | E= | R | 5145836 |
SERVICE FIRST ELECTRIC | ES | C | 01/13/2016 | Residential Underground: NEW 150 AMP SERVICE | MIKEC | MIKEC | | ES | C | 5115791 |
SERVICE FIRST ELECTRIC | ER | C | 01/13/2016 | NO CEN. VAC | MIKEC | MIKEC | | ER | C | 5115790 |
GENE'S HEATING AND AIR LLC | H= | C | 04/01/2016 | NO DOORS TO THE BASEMENT, FULLY LOUVERED DOOR TO THE MECHANICAL ROOM, THE A/C IS NOT COMPLETE. OUTSIDE AIR TO THE RETURN DUCT AND 2 - 14 X 12 TRANSFER GRILLS, HIGH AND LOW, ON THE MECHANICAL ROOM WALL. | JEFFB | JEFFB | | H= | C | 5167699 |
KAMPP-L ENTERPRISES, INC. | HC | C | 01/14/2016 | RELEASE METER | TAYLOR | TAYLOR | | HC | C | 5116190 |
KAMPP-L ENTERPRISES, INC. | HI | C | 01/14/2016 | 10 lb test ok, 1 1/4 main, 1 furnace, 1 water heater, 1 fireplace, 1 range, note: fireplace stub only in wall, re- check support in garage at final. | TAYLOR | TAYLOR | | HI | C | 5116189 |
GENE'S HEATING AND AIR LLC | HRR | C | 01/12/2016 | Finish connection at outside air/mechanical room by final. Note: Duct design, equipment matches, A/C coil and line-set, outside air to return, basement finish. | STEVEC | STEVEC | | HRR | C | 5114398 |
KAMPP-L ENTERPRISES, INC. | P= | C | 04/06/2016 | corrections made. | TAYLOR | TAYLOR | | P= | C | 5170914 |
KAMPP-L ENTERPRISES, INC. | P= | T | 04/05/2016 | PAID (REC#1322166) no corrections made. | TAYLOR | TAYLOR | | P= | T | 5170257 |
KAMPP-L ENTERPRISES, INC. | P= | P | 04/01/2016 | need trap guard at floor drain in mech room and hammer arrestor at ice maker, rest ok, finished basement, no irrigation. | TAYLOR | TAYLOR | | P= | P | 5167794 |
KAMPP-L ENTERPRISES, INC. | PTO | C | 01/05/2016 | corrections made. | TAYLOR | TAYLOR | | PTO | C | 5110162 |
KAMPP-L ENTERPRISES, INC. | PTO | R | 01/04/2016 | lost test/low test washer box gage, test washer box venting into attic, not cut off in wall above box with gage in wall, note: finished basement, aav on powder bath and basement lavs | TED | TED | | PTO | R | 5109319 |
KAMPP-L ENTERPRISES, INC. | PB | C | 11/09/2015 | | TAYLOR | TAYLOR | | PB | C | 5075410 |