ALLRIGHT PLUMBING & HEATING | BE | L | 06/17/2020 | Renewed for $50.00 at 6/17/2020 8:24:50 AM (Receipt#1688834) | JANE | JANE | | BE | L | 6607148 |
ALLRIGHT PLUMBING & HEATING | BE | L | 03/18/2019 | Renewed at 3/18/2019 11:48:15 AM | JANE | JANE | | BE | L | 6135434 |
ALLRIGHT PLUMBING & HEATING | B= | P | 05/30/2018 | Previous items complete. Additional Inspections Required (computer generated): External Agency Inspection F= by FIREDEPT is not Completed yet (Contact: 385-5982, x2). | RICHB | RICHB | | B= | P | 5858711 |
ALLRIGHT PLUMBING & HEATING | B= | R | 05/29/2018 | Unable to inspect - no answer at door, spoke with Contractor - will reschedule, preferably AM inspection (after 9:30). Additional Inspections Required (computer generated): External Agency Inspection F= by FIREDEPT is not Completed yet (Contact: 385-5982, x2). | RICHB | RICHB | | B= | R | 5857499 |
ALLRIGHT PLUMBING & HEATING | BE | L | 05/25/2018 | Renewed for Full Fee at 5/25/2018 1:20:21 PM (Receipt#1502954) | RITA | RITA | | BE | L | 5856370 |
ALLRIGHT PLUMBING & HEATING | BE | L | 07/25/2017 | Renewed for 1/2 Fee at 7/25/2017 11:22:58 AM (Receipt#1441666) | TERRI | TERRI | | BE | L | 5574818 |
ALLRIGHT PLUMBING & HEATING | B= | R | 01/23/2017 | need to install grab bars in restroom per ANSI A117.1-2003 / need to install accessible sign for bathroom / need to install accessible hardware on doors per ANSI A117.1-2003 / sink is installed less than 60" from toilet wall per ANSI A117.1-2003 needs to have 60" clear from the side wall of the toilet / need complete all other final inspections. Additional Inspections Required (computer generated): External Agency Inspection F= by FIREDEPT is not Completed yet (Contact: 385-5982, x2). | ERICR | ERICR | | B= | R | 5395680 |
ALLRIGHT PLUMBING & HEATING | B= | P | 01/23/2017 | Test and Balance Report / next time send this to mechanical -- Schedule a new Building Final when above items are complete. Additional Inspections Required (computer generated): External Agency Inspection F= by FIREDEPT is not Completed yet (Contact: 385-5982, x2), ALLRIGHT PLUMBING & HEATING Mechanical Final Inspection is not Completed yet. | ERICR | ERICR | | B= | P | 5395064 |
ALLRIGHT PLUMBING & HEATING | BSP | T | 01/13/2017 | PAID (REC#1394987) PLAN SPLICE FEE: $50 by: JUSTINC for Mechanical: splice to change gas and rtu btu | JUSTINC | JUSTINC | | BSP | T | 5388596 |
ALLRIGHT PLUMBING & HEATING | BE | C | 10/28/2016 | | JESSICAM | JESSICAM | | BE | C | 5330463 |
ALLRIGHT PLUMBING & HEATING | BIN | P | 03/08/2016 | Insulation OK pending all roughs complete | NICK | NICK | | BIN | P | 5150234 |
ALLRIGHT PLUMBING & HEATING | BFR | P | 03/08/2016 | Eng letter for CMU wall and posts for canopy on file / Backing installed / Need all rough complete | NICK | NICK | | BFR | P | 5150227 |
ALLRIGHT PLUMBING & HEATING | BFR | P | 02/12/2016 | Need backing for grab bars in accessible restroom / Discussed all accessible elements with contractor / Need engineering for CMU wall added on top of foundation walls. Also need eng. for posts at canopy supported on stem walls / Complete all other rough inspections / OK to insulate | JEREMYA | JEREMYA | | BFR | P | 5133296 |
VALLEY ELECTRIC | E= | C | 04/25/2016 | | CRAIGS | CRAIGS | | E= | C | 5184234 |
VALLEY ELECTRIC | E= | L | 04/22/2016 | locked @4:30 | CRAIGS | CRAIGS | | E= | L | 5183200 |
VALLEY ELECTRIC | E= | R | 04/12/2016 | drinking fountain receptacle needs gfci protection --- if you use a receptacle then the drinking fountain has to be in place so i can verify that it's not inside the drinking fountain --- if you use a breaker then i just need to test it ---- 30 amp A/C OK | CRAIGS | CRAIGS | | E= | R | 5175374 |
VALLEY ELECTRIC | ER | P | 02/24/2016 | patio cover 4 can lights OK | CRAIGS | CRAIGS | | ER | P | 5141785 |
LONE STAR ELECTRIC LLC | ES | C | 11/19/2015 | Commercial Service: 200 amp service upgrade and relocate. | BRET | BRET | | ES | C | 5082007 |
LONE STAR ELECTRIC LLC | ER | P | 11/19/2015 | interior ok. canopy not ready. | BRET | BRET | | ER | P | 5081997 |
LONE STAR ELECTRIC LLC | ES | R | 11/05/2015 | Commercial Service: need guy mast to cspu standards ----- use 1/4" lags it the mast support below the eve ---- need inter system bond terminal before final --- need a bond bushing on nipple from panel to meter-- complete re inspection required | CRAIGS | CRAIGS | | ES | R | 5073418 |
ALLRIGHT PLUMBING & HEATING | H= | C | 01/23/2017 | MECHANICAL FINAL OK. TEST AND BALANCE REPORT RECEIVED. | NANCY | NANCY | | H= | C | 5395164 |
ALLRIGHT PLUMBING & HEATING | H= | P | 01/17/2017 | MECHANICAL FINAL OK PENDING RECEIPT OF TEST AND BALANCE REPORT. | NANCY | NANCY | | H= | P | 5389653 |
ALLRIGHT PLUMBING & HEATING | H= | P | 05/02/2016 | INSTALL 20 X 10 RETURN AIR GRILL FOR FITNESS AREA AS PER PRINTS. NEED REVISED/APPROVED PRINTS. PROVIDE TEST AND BALANCE REPORT. | NANCY | NANCY | | H= | P | 5189894 |
ALLRIGHT PLUMBING & HEATING | HC | C | 04/29/2016 | 100,000 BTU FURNACE INSTALLED IN CLUB HOUSE. | NANCY | NANCY | | HC | C | 5187839 |
ALLRIGHT PLUMBING & HEATING | HI | C | 04/29/2016 | NEED REVISED/APPROVED PRINTS. PRINTS SHOW 1 INCH GAS LINE TO FURNACE, 1/2 INCH INSTALLED, 100,000 BTU FURNACE INSTALLED, EQUIPMENT SCHEDULE CALLS FOR 132,000 BTU FURNACE. PLUMBING SCHEDULE SHOWS A NEW 2 GALLON WATER HEATER TO BE INSTALLED, USING EXISTING WATER HEATER INSTEAD OF NEW ONE. 10 LB TEST OK ON GAS LINE TO FURNACE. | NANCY | NANCY | | HI | C | 5187836 |
ALLRIGHT PLUMBING & HEATING | HD | P | 01/28/2016 | NEED GAS PERMIT FOR NEW GAS LINE TO FURNACE, ( ROUGH DUCT OK.) NOTE: DIRECT VENT FURNACE, NO OUTSIDE AIR, A/C ROUGH LINE SET AND COIL.. SLAB ON GRADE. | LUKE | LUKE | | HD | P | 5125208 |
ALLRIGHT PLUMBING & HEATING | P= | C | 05/02/2016 | | TAYLOR | TAYLOR | | P= | C | 5189572 |
ALLRIGHT PLUMBING & HEATING | P= | L | 04/29/2016 | called by mistake | DICK | DICK | | P= | L | 5188047 |
ALLRIGHT PLUMBING & HEATING | PB | C | 01/27/2016 | | TED | TED | | PB | C | 5124206 |
ALLRIGHT PLUMBING & HEATING | PTO | C | 01/27/2016 | to plan | TED | TED | | PTO | C | 5124202 |
ALLRIGHT PLUMBING & HEATING | PB | P | 09/25/2015 | need all the rest of the contractors attached to permit before this part can be completed, change this inspection from pto to pb, base is to plan, test on copper water main ok, call inspector after permit is corrected so it can be completed and piping covered 799-2860 | TED | TED | | PB | P | 5044160 |