EXECUTIVE CUSTOM CONSTRUCTION, INC. | B= | C | 03/30/2016 | All other required Final inspections are complete. (This is a computer generated result) | BOBF | BOBF | | B= | C | 5165853 |
EXECUTIVE CUSTOM CONSTRUCTION, INC. | B= | P | 02/19/2016 | . Additional Inspections Required (computer generated): External Agency Inspection F= by FIREDEPT is not Completed yet (Contact: 385-5982, x2), External Agency Inspection Z= by ZONING is not Completed yet (Contact: 719-385-5982). | BOBF | BOBF | | B= | P | 5137825 |
EXECUTIVE CUSTOM CONSTRUCTION, INC. | BFR | P | 01/11/2016 | pending other required inspections framing for restrooms and utility room okay / reviewed accessible requirements | BOBF | BOBF | | BFR | P | 5113463 |
EXECUTIVE CUSTOM CONSTRUCTION, INC. | BIN | P | 01/11/2016 | box headers and stud packs insulated | BOBF | BOBF | | BIN | P | 5113460 |
EXECUTIVE CUSTOM CONSTRUCTION, INC. | BIN | P | 01/08/2016 | INSULATION IN NORTHWEST CORNER OKAY, ALAN PLEASE CONTACT ME REGARDING BOX HEADERS AND STUD PACKS | BOBF | BOBF | | BIN | P | 5112723 |
EXECUTIVE CUSTOM CONSTRUCTION, INC. | BIN | P | 01/04/2016 | need to verify insulation in box headers and stud packs / pending other required inspections north and west full height walls okay except room in far northwest corner | BOBF | BOBF | | BIN | P | 5109217 |
EXECUTIVE CUSTOM CONSTRUCTION, INC. | BLA | C | 12/22/2015 | north side complete | DANE | DANE | | BLA | C | 5103988 |
EXECUTIVE CUSTOM CONSTRUCTION, INC. | BLA | R | 12/11/2015 | need to complete north side / other 3 sides OK | DANE | DANE | | BLA | R | 5097492 |
EXECUTIVE CUSTOM CONSTRUCTION, INC. | BFR | P | 11/10/2015 | provide welding cert letter for all welding, exterior frame and bar joists okay pending other required inspections / need eng letters for footing and foundation / | BOBF | BOBF | | BFR | P | 5076449 |
EXECUTIVE CUSTOM CONSTRUCTION, INC. | BFT | P | 09/22/2015 | ok for eng to inspect footing and foundation / letters to follow | JOHN | JOHN | | BFT | P | 5041410 |
EXECUTIVE CUSTOM CONSTRUCTION, INC. | BFI | P | 09/21/2015 | Partial pending receipt of open hole report and footing/foundation letters . | TOMG | TOMG | | BFI | P | 5040297 |
BIBLE ELECTRIC, INC. | E= | C | 02/08/2016 | | BRET | BRET | | E= | C | 5129772 |
BIBLE ELECTRIC, INC. | E= | R | 02/05/2016 | gfci receptacles within 6' of mop sink. | BRET | BRET | | E= | R | 5129097 |
BIBLE ELECTRIC, INC. | ES | C | 01/14/2016 | Commercial Service: 400 amp service ok to energize | BRET | BRET | | ES | C | 5116065 |
BIBLE ELECTRIC, INC. | ER | C | 01/11/2016 | | BRET | BRET | | ER | C | 5113541 |
BIBLE ELECTRIC, INC. | ER | P | 12/30/2015 | exterior walls, ground pigtails and access for sign boxes. | BRET | BRET | | ER | P | 5107678 |
BIBLE ELECTRIC, INC. | EUG | R | 11/16/2015 | call csu for inspection | BRET | BRET | | EUG | R | 5080034 |
BIBLE ELECTRIC, INC. | EUG | P | 11/09/2015 | east and south lighting underground stubbed into islands not ran to building at this time. | BRET | BRET | | EUG | P | 5075541 |
BIBLE ELECTRIC, INC. | ESL | R | 10/20/2015 | call csu for inspection can not run service conductors under building. pvc conduits for site lighting under slab ok. | BRET | BRET | | ESL | R | 5061698 |
BIBLE ELECTRIC, INC. | EUG | P | 09/11/2015 | ufer ok #4 north wall foundation | BRET | BRET | | EUG | P | 5034545 |
FRONTIER MECHANICAL SYSTEMS INC | H= | C | 02/08/2016 | GAS FINAL OK. | NANCY | NANCY | | H= | C | 5130233 |
NIELSEN MECHANICAL CONTRACTORS, INC. | H= | C | 02/08/2016 | MECHANICAL FINAL OK. NOTE: EXTRA RUNS DELETED ON SHELL BEING INSTALLED AS PER TENANT FINISH PRINT. | NANCY | NANCY | | H= | C | 5130231 |
NIELSEN MECHANICAL CONTRACTORS, INC. | HD | P | 01/14/2016 | THE STAMPED SET OF PRINTS WITH A REVISION DATED 7/29/15 DELETES THREE OF THE SPIRAL TRUNK LINES THAT HAVE BEEN INSTALLED. EXHAUST AND SUPPLY ABOVE BATHROOM HARD LIDS OK. NO ROOF YET. | NANCY | NANCY | | HD | P | 5116672 |
FRONTIER MECHANICAL SYSTEMS INC | HC | C | 12/21/2015 | OK TO SET METER. | NANCY | NANCY | | HC | C | 5103354 |
FRONTIER MECHANICAL SYSTEMS INC | HI | C | 12/21/2015 | GAS INSTALLED AS PER PRINTS. | NANCY | NANCY | | HI | C | 5103335 |
FRONTIER MECHANICAL SYSTEMS INC | HI | P | 12/18/2015 | NO LADDER FOR ROOF ACCESS TO VERIFY INSTALL OR SIZING. 10 LB TEST OK TODAY. | NANCY | NANCY | | HI | P | 5102037 |
FRONTIER MECHANICAL SYSTEMS INC | P= | C | 02/17/2016 | CORRECTIONS MADE , | GABE | GABE | | P= | C | 5135667 |
FRONTIER MECHANICAL SYSTEMS INC | P= | R | 02/16/2016 | cancelled | JOEL | JOEL | | P= | R | 5134858 |
FRONTIER MECHANICAL SYSTEMS INC | P= | P | 02/09/2016 | NEED TO UNCOVER FLOOR DRAIN IN BATH ROOM , NEED TRAP GUARD IN MEC , REST OK | GABE | GABE | | P= | P | 5130879 |
FRONTIER MECHANICAL SYSTEMS INC | PTO | C | 01/07/2016 | NOTE : DWV AND WATER ON TEST , ALL TO PLAN , WILL NEED TRAP GUARD AT BATH FLOOR DRAIN , | GABE | GABE | | PTO | C | 5111869 |
FRONTIER MECHANICAL SYSTEMS INC | PB+ | C | 10/22/2015 | DWV ON TEST | GABE | GABE | | PB+ | C | 5063245 |
FRONTIER MECHANICAL SYSTEMS INC | PB+ | P | 10/21/2015 | MAIN LOCATION CHANGED , DESIGN OK , NEED TO TEST | GABE | GABE | | PB+ | P | 5062595 |
FRONTIER MECHANICAL SYSTEMS INC | PB | C | 09/24/2015 | BASE TO PLAN , COPPER RUN UNDER FOOTER | GABE | GABE | | PB | C | 5043593 |