OAKWOOD HOMES, LLC | B= | C | 01/08/2016 | Items corrected | JEREMYA | JEREMYA | | B= | C | 5112839 | OAKWOOD HOMES, LLC | BIN | C | 01/08/2016 | Third party cert on file | JEREMYA | JEREMYA | | BIN | C | 5112835 | OAKWOOD HOMES, LLC | B= | P | 01/07/2016 | Need third party insulation inspection certificate | JEREMYA | JEREMYA | | B= | P | 5112254 | OAKWOOD HOMES, LLC | BFR | C | 11/25/2015 | item corrected | JEREMYA | JEREMYA | | BFR | C | 5087493 | OAKWOOD HOMES, LLC | BFR | P | 11/23/2015 | still need to draft stop top of chase at end of tub at front bedroom / all other items corrected | DANE | DANE | | BFR | P | 5085948 | OAKWOOD HOMES, LLC | BFR | R | 11/18/2015 | portal wall not nailed per detail at header / missing jack straps at portal wall on inside of garage / anchor bolt each side of plate breaks / nail off fha strap at laundry room / 5- 2x6 post under T03x east end / draftstop chase behind tub front bedroom / okay to insulate | BOBF | BOBF | | BFR | R | 5081705 | OAKWOOD HOMES, LLC | BIN | P | 11/13/2015 | Qualified third party energy inspection documentation must be presented at time of final building (B=) inspection | INTERNET | INTERNET | | BIN | P | 5079369 | OAKWOOD HOMES, LLC | BFD | C | 11/12/2015 | engineer observation report on file for BFD BFN BFT | DANE | DANE | | BFD | C | 5077014 | OAKWOOD HOMES, LLC | BFN | P | 11/10/2015 | Foundation design on file / Need foundation observation | JEREMYA | JEREMYA | | BFN | P | 5076005 | OAKWOOD HOMES, LLC | BFT | C | 11/10/2015 | Soils on file | JEREMYA | JEREMYA | | BFT | C | 5076003 | FOUNTAIN VALLEY ELECTRICAL, LLC | E= | C | 01/06/2016 | | TOMC | TOMC | | E= | C | 5111477 | FOUNTAIN VALLEY ELECTRICAL, LLC | E= | R | 01/05/2016 | gfci outlet in master closet, attic light not working, provide ladder for crawler, label second switch in laundry room going into living room-------- 30 amp a/c ok | MATTHEW | MATTHEW | | E= | R | 5109768 | FOUNTAIN VALLEY ELECTRICAL, LLC | ER | C | 11/13/2015 | | JOSEPH | JOSEPH | | ER | C | 5078968 | FOUNTAIN VALLEY ELECTRICAL, LLC | ES | C | 11/12/2015 | Residential Underground: 200 amp 3/w: new res | MATTHEW | MATTHEW | | ES | C | 5078117 | FOUNTAIN VALLEY ELECTRICAL, LLC | ER | R | 11/12/2015 | nail plate thru out (check above panel, laundry, master bath, stair and mech wall, move upper bath outlet above counter, install running boards------------- crawler, no mcc's, #6al, irreversible ufer, no vac | MATTHEW | MATTHEW | | ER | R | 5078112 | STEEL-T HEATING, INC. | H= | C | 01/06/2016 | Correction made. Combustion air from ventilated attic. | JEFFL | JEFFL | | H= | C | 5110885 | STEEL-T HEATING, INC. | H= | P | 01/04/2016 | No combustion air to mech room. Rest ok Notes-- AC complete. | JEFFL | JEFFL | | H= | P | 5109299 | STEEL-T HEATING, INC. | HC | C | 11/16/2015 | RELEASE METER | JEFFL | JEFFL | | HC | C | 5079933 | STEEL-T HEATING, INC. | HRR | C | 11/16/2015 | Notes-- AC rough coil and line set. Conditioned crawl space. Duct design.. **Duct leakage report needed at final. | JEFFL | JEFFL | | HRR | C | 5079931 | BLUE FLAME GAS COMPANY, INC. | HI | C | 11/05/2015 | 10# gas test good. 3/4'' main furnace water heater.. | LUKE | LUKE | | HI | C | 5073643 | B & L PLUMBING, INC. | P= | C | 01/04/2016 | pvb installed | TIM | TIM | | P= | C | 5109285 | B & L PLUMBING, INC. | PTO | C | 11/09/2015 | crawlspace | TED | TED | | PTO | C | 5075643 | B & L PLUMBING, INC. | PB | C | 10/15/2015 | crawlspace | TED | TED | | PB | C | 5058433 |
|
|