HOMEOWNER | B= | C | 11/10/2016 | finished basement, deck in | DALE | DALE | | B= | C | 5342122 |
HOMEOWNER | BIN | C | 06/10/2016 | | BOBF | BOBF | | BIN | C | 5220448 |
HOMEOWNER | BLA | C | 06/10/2016 | | BOBF | BOBF | | BLA | C | 5220426 |
HOMEOWNER | BFR | C | 06/10/2016 | | BOBF | BOBF | | BFR | C | 5220425 |
HOMEOWNER | BFR | P | 06/08/2016 | OK to insulate -- Still need FHA straps at gas line at garage and kitchen bearing walls and plumbing PVC pipes in hall bathroom -- Finish foam and firestop | DAKOTAB | DAKOTAB | | BFR | P | 5218197 |
HOMEOWNER | BFR | R | 06/02/2016 | porch and narrow wall covered and no record of inspection --strap all top plates notched where plumbing /gas lines penetrate -- drafstop all top plate penetrations -- missing saddle at steel 4x4 -- missing SDS screws at bearing block at B1 -- C2 missing 2 HTS20's -- need 5 2x4 under steel beam in bedroom 3 -- 6 2x4 under w12x30 and 6 2x4 under stair corner need to be pressure treated if buried in slab -- finish nailing CS16 at landing | SCOTTS | SCOTTS | | BFR | R | 5213528 |
HOMEOWNER | BSP | T | 03/24/2016 | PAID (REC#1319947) PLAN SPLICE FEE: $50 by: JIMA for Construction: splice changed master bath / remove f,pl. / added window and sgd | JIMA | JIMA | | BSP | T | 5161972 |
HOMEOWNER | BSP | P | 03/22/2016 | PLAN SPLICE: (No Fee) by: DALEH for Mechanical | DALEH | DALEH | | BSP | P | 5159957 |
HOMEOWNER | BSP | P | 10/08/2015 | eng letter to bell deck piers on file / 3 deck piers okay | BOBF | BOBF | | BSP | P | 5053775 |
HOMEOWNER | BSP | R | 10/06/2015 | foundation design calls for 2-18" and 1-24" piers / piers dug are 2-14" and 1-18" | BOBF | BOBF | | BSP | R | 5051979 |
HOMEOWNER | BFD | C | 09/28/2015 | | DALE | DALE | | BFD | C | 5045655 |
HOMEOWNER | BFI | C | 09/28/2015 | | DALE | DALE | | BFI | C | 5045647 |
HOMEOWNER | BFN | C | 09/23/2015 | design and open hole on file / 7 interior pads | BOBF | BOBF | | BFN | C | 5042948 |
HOMEOWNER | BFT | C | 09/17/2015 | check interior pads at foundation | BOBF | BOBF | | BFT | C | 5038988 |
HOMEOWNER | E= | C | 11/07/2016 | | CRAIG | CRAIG | | E= | C | 5337689 |
HOMEOWNER | E= | R | 11/03/2016 | exterior outlets need to be wr type, need tr outlets:office and appliance garage in kitchen and under sub-panel, front guest bath has no power to gfci and needs gfci protection for all outlets, gfci outlet above master toilet and outlets in basement bath, both laundry areas need gfci and afci protection, afci kitchen circuits, remove gfci device from behind wet bar fridge, need combo afci in basement sub-panel, ground pendant above kitchen sink | MATTHEW | MATTHEW | | E= | R | 5335838 |
HOMEOWNER | E= | R | 10/28/2016 | complete re-inspect------ need wr and extra duty in-use cover that hinge from the top at all exterior outlets, make up hot tub disconnect, gfci garage outlets, need tr outlets thru out (mostly in garage and kitchen), gfci all outlets within 6' of bath sinks, need dedicated circuit to dish/disposal, need additional circuit for insta-hot, afci per 2014, gfci laundry outlets, gfci tests can't be behind appliances, dryers need to be on 30 amp breakers, check range nameplates for correct breaker sizes, gfci all outlets in mech room ------------complete re-inspect (I did not check a lot of outlets since they would be changed out)------------ no a/c and hot tub pre-wire | MATTHEW | MATTHEW | | E= | R | 5331000 |
HOMEOWNER | ER | C | 05/23/2016 | | CRAIG | CRAIG | | ER | C | 5206195 |
HOMEOWNER | ER | R | 05/19/2016 | add outlets in study / craft room / bedroom in basement ---------- in wet bar area install uf cable ( under grd ) ---------- back porch outlet can' t be on small app. ------------ install grd bar and separate neutral and grds in sub panel ------------- no mcc 2 - 10/3 3 - 6/3 cu 4/w #2 al to sub panel in finished basement no cen vac complete re inspect note talked to owner about tr / afci / gfi and all dedicated circuits | CRAIG | CRAIG | | ER | R | 5204086 |
HOMEOWNER | ES | C | 03/24/2016 | Residential Underground: 200 amp 3/w new res ok to set meter | CRAIG | CRAIG | | ES | C | 5162044 |
HOMEOWNER | EUG | C | 03/07/2016 | 3/w 250 mcm al service lateral | CRAIG | CRAIG | | EUG | C | 5149413 |
HOMEOWNER | ES | R | 03/07/2016 | Residential Underground: not ready ------- install both riser ----------- install main panel in garage | CRAIG | CRAIG | | ES | R | 5149412 |
MILLER HEATING & AIR CONDITIONING, INC. | H= | C | 11/07/2016 | Microwave exhaust in basement is for future use. | MICHAELS | MICHAELS | | H= | C | 5338344 |
MILLER HEATING & AIR CONDITIONING, INC. | H= | L | 11/04/2016 | House is locked, unable to access for exhaust vent in basement. Furnace vent termination ok. | MARK | MARK | | H= | L | 5336697 |
MILLER HEATING & AIR CONDITIONING, INC. | H= | P | 10/28/2016 | Need furnace manual to verify termination, complete hood exhaust in basement. Note: finished basement, louvered door to mech, no a/c, mantels ok. | MICHAELS | MICHAELS | | H= | P | 5331112 |
HOMEOWNER | HC | C | 05/24/2016 | RELEASE METER | MARK | MARK | | HC | C | 5206646 |
HOMEOWNER | HI | C | 05/24/2016 | 10lb test ok. Note: 1 1/2" main. Furnace, water heater, range, gas dryer, future bbq, 2- fireplaces. | MARK | MARK | | HI | C | 5206640 |
MILLER HEATING & AIR CONDITIONING, INC. | HRR | C | 05/20/2016 | Rough ok. Note: finished basement, no osa, no a/c, indirect vent furnace. | MICHAELS | MICHAELS | | HRR | C | 5205193 |
HOMEOWNER | P= | C | 11/10/2016 | received potable water cert | TIM | TIM | | P= | C | 5341148 |
HOMEOWNER | P= | P | 11/03/2016 | need potable water cert | TIM | TIM | | P= | P | 5335347 |
HOMEOWNER | PTO | C | 05/24/2016 | | TIM | TIM | | PTO | C | 5206882 |
HOMEOWNER | PWO | C | 03/01/2016 | | TIM | TIM | | PWO | C | 5145615 |
HOMEOWNER | PB | C | 10/05/2015 | | TIM | TIM | | PB | C | 5050618 |