MAJESTIC CUSTOM HOMES, INC. | B= | C | 03/16/2017 | | BOBF | BOBF | | B= | C | 5443413 |
MAJESTIC CUSTOM HOMES, INC. | BLA | C | 02/02/2017 | | DALE | DALE | | BLA | C | 5405615 |
MAJESTIC CUSTOM HOMES, INC. | BIN | C | 01/23/2017 | | BOBF | BOBF | | BIN | C | 5396096 |
MAJESTIC CUSTOM HOMES, INC. | BFR | C | 01/23/2017 | letter for cantilever in garage on file | BOBF | BOBF | | BFR | C | 5396084 |
MAJESTIC CUSTOM HOMES, INC. | BFR | R | 01/18/2017 | need revised plan for extended cantelever in garage including post and pad support / 5 - 2x4 post at midpoint of double LVL over laundry / missing Lateral at S02's / provide solid block shim for support of steel beam in basement, both ends / floating walls to be nailed 32" oc / okay to insulate | BOBF | BOBF | | BFR | R | 5392086 |
MAJESTIC CUSTOM HOMES, INC. | BSP | P | 01/10/2017 | Missing straps at narrow braced wall -- Missing (2) lags at rear deck ledger -- Missing skewed LUS28's at deck joist to cantilever -- Missing LUS28 to post at deck joist -- Missing ST18 at interior bearing location for both beams for rear porch -- Front porch post and lid OK -- Rear porch post and lid OK | DAKOTAB | DAKOTAB | | BSP | P | 5385511 |
MAJESTIC CUSTOM HOMES, INC. | BSP | P | 09/22/2016 | Item corrected -- 4 piers OK | DAKOTAB | DAKOTAB | | BSP | P | 5300471 |
MAJESTIC CUSTOM HOMES, INC. | BSP | R | 09/19/2016 | Foundation plan calls out for piers to be (2) 30" and (2) 36" diameter -- Piers on site are 25" and 28" | DAKOTAB | DAKOTAB | | BSP | R | 5296926 |
MAJESTIC CUSTOM HOMES, INC. | BFD | C | 08/22/2016 | eng letter for drain on file | BOBF | BOBF | | BFD | C | 5274980 |
MAJESTIC CUSTOM HOMES, INC. | BFI | C | 08/22/2016 | 2" R-10 Rigid | BOBF | BOBF | | BFI | C | 5274977 |
MAJESTIC CUSTOM HOMES, INC. | BFT | P | 08/22/2016 | soil report, open hole and design on file, still need letter for footing , can upload letter with next insp request | BOBF | BOBF | | BFT | P | 5274973 |
MAJESTIC CUSTOM HOMES, INC. | BFN | R | 08/22/2016 | no eng letter for foundation and eufer left on site, can up load with next inspection request | BOBF | BOBF | | BFN | R | 5274968 |
MAJESTIC CUSTOM HOMES, INC. | BE | L | 05/17/2016 | Renewed for 1/2 Fee at 5/17/2016 12:39:28 PM (Receipt#1329992) | MINDY | MINDY | | BE | L | 5201041 |
MAJESTIC CUSTOM HOMES, INC. | BFT | P | 09/15/2015 | AUTHORIZED INSPECTION BY ENGINEER | REBECCA | REBECCA | REBECCA | BFT | P | 5036278 |
MAJESTIC CUSTOM HOMES, INC. | BFN | P | 09/15/2015 | AUTHORIZED INSPECTION BY ENGINEER | REBECCA | REBECCA | REBECCA | BFN | P | 5036277 |
ROWAN ELECTRIC LLC | E= | C | 03/15/2017 | contractor installing class 2 transformer. note 12 awg uf in trench to future driveway lights ok to cover. Will require permit and gfci protection when lights installed | BRET | BRET | | E= | C | 5441732 |
ROWAN ELECTRIC LLC | EP | C | 03/10/2017 | 100 amp 4/w to sub panel ok | CRAIG | CRAIG | | EP | C | 5438185 |
ROWAN ELECTRIC LLC | E= | R | 03/10/2017 | where is xfmr for light in hallway by laundry door ???? -------------- A/C pre wire only / | CRAIG | CRAIG | | E= | R | 5438182 |
ROWAN ELECTRIC LLC | E= | R | 03/06/2017 | bad gfci front door, wet tile laundry and wet bar, install receptacle and face box toward jet tub access, strap riser , wire a/c. master vanity receptacles hanging out of wall. complete re-inspect. | BRET | BRET | | E= | R | 5432701 |
ROWAN ELECTRIC LLC | ER | C | 01/17/2017 | | MATTHEW | MATTHEW | | ER | C | 5390788 |
ROWAN ELECTRIC LLC | ES | C | 01/12/2017 | Residential Underground: 200 - amp 3 Wire service, ok to seal meter / | CRAIG | CRAIG | | ES | C | 5388188 |
ROWAN ELECTRIC LLC | ER | R | 01/12/2017 | install grd screw in exterior pan box ----------- nail plate feeder in guest toilet ---------- no mcc 4/w #2 al to sub panel in finished basement 2 - 6/3 al to oven / ac 2 - 10/3 to dryer / well no cen vac finished basement non irr | CRAIG | CRAIG | | ER | R | 5388186 |
PEAK ELECTRIC INC. | EUG | C | 09/15/2016 | 3/w 4/0 al service lateral | CRAIG | CRAIG | | EUG | C | 5294292 |
THE FURNACE GUY HEATING & COOLING | H= | C | 03/06/2017 | Correction made. | JEFFL | JEFFL | | H= | C | 5432315 |
THE FURNACE GUY HEATING & COOLING | H= | P | 03/03/2017 | Furnace vent termination not complete. Rest ok. Notes-- high/low transfer air to mech room. AC rough coil and line set. | JEFFL | JEFFL | | H= | P | 5431092 |
SPRINGS GAS, INC. | HC | C | 01/12/2017 | RELEASE METER | MARK | MARK | | HC | C | 5387655 |
SPRINGS GAS, INC. | HI | C | 01/12/2017 | 10 lb test ok. Note: 1 1/4" main. Furnace, water heater, fireplace and cook top. | MARK | MARK | | HI | C | 5387636 |
THE FURNACE GUY HEATING & COOLING | HRR | C | 01/12/2017 | Equipment does not match, change letter by final. Rough ok. Note: Finished basement, a/c coil and line set rough, direct vent., 6" outside air to the return.
| MARK | MARK | | HRR | C | 5387602 |
PACIFIC PLUMBING, INCORPORATED | P= | C | 03/15/2017 | correction made | TED | TED | | P= | C | 5441401 |
PACIFIC PLUMBING, INCORPORATED | P= | P | 03/15/2017 | certificate of potable water to scanning | TED | TED | | P= | P | 5441091 |
PACIFIC PLUMBING, INCORPORATED | P= | R | 03/13/2017 | need to complete basement shower tile work for test, (grouting at this time), need certificate of potable water, note: rest ok, finished basement, basement powder bath rough only, 3/4'' pvb installed | TED | TED | | P= | R | 5439125 |
PACIFIC PLUMBING, INCORPORATED | P= | P | 03/10/2017 | no hot water temp. (water turned down) reinspect all, need certificate of potable water, note: master tub pump access in closet | TED | TED | | P= | P | 5437458 |
HOMEOWNER | PWO | C | 01/26/2017 | PIPE SLEEVED THROUGH FOUNDATION , NEED POTABLE WATER CERT BY FINAL | GABE | GABE | | PWO | C | 5399419 |
PACIFIC PLUMBING, INCORPORATED | PTO | C | 01/12/2017 | CORRECTIONS MADE | GABE | GABE | | PTO | C | 5387684 |
PACIFIC PLUMBING, INCORPORATED | PTO | P | 01/11/2017 | LOW TEST AT MASTER DWV , REST OK . NOTE : FINISHED BASEMENT , AAV AT BAR , BASEMENT POWDER ROUGH ONLY , TEMPERING AT MASTER LAV , IRRIGATION STUB , RECIRC INSTALLED , NEED PWO NO WATER IN | GABE | GABE | | PTO | P | 5386779 |
PACIFIC PLUMBING, INCORPORATED | PB | C | 09/12/2016 | DWV ON TEST , NO WATER IN | GABE | GABE | | PB | C | 5290502 |