ASPEN VIEW HOMES, LLC | B= | C | 02/18/2016 | Corrections complete / Finished basement / Rear deck attached | JEREMYA | JEREMYA | | B= | C | 5137611 |
ASPEN VIEW HOMES, LLC | B= | R | 02/16/2016 | Field Cancel. Additional Inspections Required (computer generated): External Agency Inspection N= by ENGINEERING is not Completed yet (Contact: City Engineering Inspections 719-385-5977). | JEREMYA | JEREMYA | | B= | R | 5134612 |
ASPEN VIEW HOMES, LLC | B= | R | 02/12/2016 | tip downs incomplete at front of home / missing stairs at garage to house door / basement bedroom egress ladder not secured / missing all balusters at guard rail at stairs to 2nd floor / missing ladder for attic access for inspection / exterior penetrations. Additional Inspections Required (computer generated): External Agency Inspection N= by ENGINEERING is not Completed yet (Contact: City Engineering Inspections 719-385-5977). | BRIANB | BRIANB | | B= | R | 5133977 |
ASPEN VIEW HOMES, LLC | BSP | R | 01/08/2016 | no beam splice detail attached or on file / no beam splice detail on site - drywall complete at home | BRIANB | BRIANB | | BSP | R | 5112686 |
ASPEN VIEW HOMES, LLC | BIN | C | 12/18/2015 | | JEREMYA | JEREMYA | | BIN | C | 5101874 |
ASPEN VIEW HOMES, LLC | BFR | C | 12/18/2015 | Items corrected / Beam splice detail on file | JEREMYA | JEREMYA | | BFR | C | 5101872 |
ASPEN VIEW HOMES, LLC | BFR | P | 12/15/2015 | Draft stop concealed spaces / Clear B-vent combustibles / Missing siade nails in hangers at upper and lower landing / Need detail for steel beam splice in basement / OK to insulate | JEREMYA | JEREMYA | | BFR | P | 5099388 |
ASPEN VIEW HOMES, LLC | BSP | P | 12/08/2015 | rear deck piers OK | JEREMYA | JEREMYA | | BSP | P | 5094495 |
ASPEN VIEW HOMES, LLC | BSP | P | 11/25/2015 | Porch post and lid OK | JEREMYA | JEREMYA | | BSP | P | 5087592 |
ASPEN VIEW HOMES, LLC | BFN | C | 10/30/2015 | Foundation design on file | JEREMYA | JEREMYA | | BFN | C | 5069554 |
ASPEN VIEW HOMES, LLC | BFD | C | 10/29/2015 | Drain usable / Damp proofing OK | JEREMYA | JEREMYA | | BFD | C | 5068495 |
ASPEN VIEW HOMES, LLC | BFN | P | 10/29/2015 | Engineering on file / Soils on file / 10% grade / 1.5" float / 2000 psf / Need foundation design | JEREMYA | JEREMYA | | BFN | P | 5068489 |
ASPEN VIEW HOMES, LLC | BFT | C | 10/29/2015 | Engineering on file / Eufer documented | JEREMYA | JEREMYA | | BFT | C | 5068485 |
ASPEN VIEW HOMES, LLC | BFT | P | 09/16/2015 | AUTHORIZED INSPECTION BY ENGINEER | REBECCA | REBECCA | REBECCA | BFT | P | 5037643 |
ASPEN VIEW HOMES, LLC | BFN | P | 09/16/2015 | AUTHORIZED INSPECTION BY ENGINEER | REBECCA | REBECCA | REBECCA | BFN | P | 5037642 |
DELMARK ELECTRIC INC | E= | C | 02/08/2016 | | MATTHEW | MATTHEW | | E= | C | 5129868 |
DELMARK ELECTRIC INC | E= | L | 02/05/2016 | locked 10:51 | MATTHEW | MATTHEW | | E= | L | 5128935 |
DELMARK ELECTRIC INC | E= | R | 01/26/2016 | reroute nm behind basement medicine cabinet (leave exposed fpr re-inspect), guard mech light, staple nm at coach light------- a/c pre-wire | MATTHEW | MATTHEW | | E= | R | 5123288 |
DELMARK ELECTRIC INC | ER | C | 12/14/2015 | 1 - # 6 , 2 - # 10 , 1 - 15 amp mcc , no central vac , finished basement | TOMC | TOMC | | ER | C | 5098019 |
DELMARK ELECTRIC INC | ES | C | 12/09/2015 | Residential Underground: 200 amp 3/w: new res | MATTHEW | MATTHEW | | ES | C | 5095340 |
DELMARK ELECTRIC INC | ER | R | 12/09/2015 | not ready: plumbing hard pipe not installed, nail plate, stub out for exterior electrical; complete re-inspect | MATTHEW | MATTHEW | | ER | R | 5095333 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | H= | C | 02/11/2016 | CORRECTIONS MADE | CHUCKF | CHUCKF | | H= | C | 5132831 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | H= | R | 02/10/2016 | T&P DRAIN TUBE STILL MISSING - WAIVED TRIP FEE | JERRYF | JERRYF | | H= | R | 5132025 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | H= | P | 01/27/2016 | Discharge pipe to relief valve on water heater is missing. Rest ok. Note-- louver door to mech room. | JEFFL | JEFFL | | H= | P | 5124513 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HC | C | 12/14/2015 | RELEASE METER | JEFFB | JEFFB | | HC | C | 5098374 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HRR | C | 12/14/2015 | ALL ITEMS LISTED PREVIOUSLY HAVE BEEN CORRECTED. | JEFFB | JEFFB | | HRR | C | 5098367 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HRR | P | 12/11/2015 | Boots need secured to floor on upper level. Heat run in garage needs secured and sealed. Coil needs sealed in back and sides. Rest ok. Note-- Finished basement.. AC rough.. OSA to return.. Duct design. | JEFFL | JEFFL | | HRR | P | 5097338 |
MD SERVICE PLUMBING, INC. | HI | C | 12/11/2015 | 10 LB. test ok Notes-- 1'' main.. 1 furnace..1 wh.. | JEFFL | JEFFL | | HI | C | 5097331 |
MD SERVICE PLUMBING, INC. | P= | C | 01/20/2016 | finished basement, 3/4'' pvb installed | TED | TED | | P= | C | 5119666 |
MD SERVICE PLUMBING, INC. | PTO | C | 12/14/2015 | correction made | DICK | DICK | | PTO | C | 5098668 |
MD SERVICE PLUMBING, INC. | PTO | P | 12/11/2015 | frame under traps in garage....aav at master and basement | TIM | TIM | | PTO | P | 5097404 |
MD SERVICE PLUMBING, INC. | PB | C | 11/05/2015 | ok for 2012 | TED | TED | | PB | C | 5073620 |