ASPEN VIEW HOMES, LLC | B= | C | 06/09/2016 | Finished basement / Rear elevated deck off master / AC installed | JEREMYA | JEREMYA | | B= | C | 5219204 |
ASPEN VIEW HOMES, LLC | BSP | P | 06/09/2016 | Master bedroom deck frame and final OK | JEREMYA | JEREMYA | | BSP | P | 5219200 |
ASPEN VIEW HOMES, LLC | BFR | C | 05/09/2016 | Corrections complete / Engineering on file for joist changes and structural changes | JEREMYA | JEREMYA | | BFR | C | 5195118 |
ASPEN VIEW HOMES, LLC | BIN | C | 05/09/2016 | | JEREMYA | JEREMYA | | BIN | C | 5195108 |
ASPEN VIEW HOMES, LLC | BLA | C | 05/05/2016 | | JEREMYA | JEREMYA | | BLA | C | 5193131 |
ASPEN VIEW HOMES, LLC | BFR | P | 05/05/2016 | Fire block garage door opener brackets / Plans call out adjustable steel column at C01 / Need letter for BCI 600 floor joists in lieu of TJI 210 / Remove wood blocks from beam pockets / Nail off hanger at bottom of basement stairs / OK to insulate | JEREMYA | JEREMYA | | BFR | P | 5193125 |
ASPEN VIEW HOMES, LLC | BSP | P | 04/05/2016 | Front porch posts and lid OK / Narrow wall OK | JEREMYA | JEREMYA | | BSP | P | 5170584 |
ASPEN VIEW HOMES, LLC | BSP | P | 04/05/2016 | Engineering for post bearing at porch | JEREMYA | JEREMYA | | BSP | P | 5169374 |
ASPEN VIEW HOMES, LLC | BFD | C | 02/17/2016 | Drain usable / Damp proofing OK | JEREMYA | JEREMYA | | BFD | C | 5136006 |
ASPEN VIEW HOMES, LLC | BFT | C | 02/16/2016 | Engineering on file / Eufer documented | JEREMYA | JEREMYA | | BFT | C | 5135254 |
ASPEN VIEW HOMES, LLC | BFN | C | 02/16/2016 | Engineering on file / Soils on file / Foundation on file / 10% grade / 2000 psf / 1.5" float | JEREMYA | JEREMYA | | BFN | C | 5135251 |
ASPEN VIEW HOMES, LLC | BFD | R | 02/16/2016 | Not done | JEREMYA | JEREMYA | | BFD | R | 5135250 |
ASPEN VIEW HOMES, LLC | BFT | P | 09/16/2015 | AUTHORIZED INSPECTION BY ENGINEER | REBECCA | REBECCA | REBECCA | BFT | P | 5037649 |
ASPEN VIEW HOMES, LLC | BFN | P | 09/16/2015 | AUTHORIZED INSPECTION BY ENGINEER | REBECCA | REBECCA | REBECCA | BFN | P | 5037648 |
DELMARK ELECTRIC INC | E= | C | 06/08/2016 | | TOMC | TOMC | | E= | C | 5217860 |
DELMARK ELECTRIC INC | E= | R | 06/07/2016 | basement bath receptacle more than 3' from sink ------ 30 amp a/c | TOMC | TOMC | | E= | R | 5216587 |
DELMARK ELECTRIC INC | ES | C | 05/04/2016 | Residential Underground: 200 amp 3/w new res ok to set meter and seal | TOMC | TOMC | | ES | C | 5191813 |
DELMARK ELECTRIC INC | ER | C | 05/04/2016 | 200 ---- 1 - #6 , 2 - #10 , 1 - 15 amp mcc , finished basement , no central vac | TOMC | TOMC | | ER | C | 5191808 |
DELMARK ELECTRIC INC | ER | R | 05/03/2016 | not ready | MATTHEW | MATTHEW | | ER | R | 5190559 |
DELMARK ELECTRIC INC | ES | R | 05/03/2016 | not ready | MATTHEW | MATTHEW | | ES | R | 5190552 |
DELMARK ELECTRIC INC | ES | R | 04/27/2016 | install riser and secure panel | MATTHEW | MATTHEW | | ES | R | 5186015 |
DELMARK ELECTRIC INC | ER | R | 04/27/2016 | protect nm above panel, finish framing and wiring in front room, missing upper deck light?, land nm in upper bedroom closet switch, additional outlet being installed under stairs?, if under stair storage is to be rocked nm will be damaged (ran on surface)--------- finished basement, 1-15, #6al, no vac | MATTHEW | MATTHEW | | ER | R | 5186005 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | H= | C | 06/06/2016 | MECHANICAL FINAL OK.
NOTE: OPEN STAIR WAY,LOUVERED DOOR TO MECHANICAL ROOM, A/C COMPLETE, RETURN AIR PATH, FINISHED BASEMENT, LAUNDRY TRANS FER IN PLACE. | CHUCKF | CHUCKF | | H= | C | 5215795 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | H= | L | 06/03/2016 | LOCKED OUT TRIED ALL DOORS, | CHUCKF | CHUCKF | | H= | L | 5214970 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | H= | P | 06/02/2016 | NEED 1" UNDER CUT DOORS TO ALL UPPER LEVEL BEDROOMS. REST OK. NOTE: FINISHED BASEMENT, DOOR AT TOP OF STAIRS, LOUVER DOOR TO MECHANICAL ROOM, 6" OUTSIDE AIR TO RETURN, A/C COMPLETE. | PAULO | PAULO | | H= | P | 5213591 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HC | C | 05/03/2016 | RELEASE METER | PAULO | PAULO | | HC | C | 5190822 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HRR | C | 05/03/2016 | CORRECTIONS MADE. NOTE: FINISHED BASEMENT, DUCT DESIGN, 6" OUTSIDE AIR TO RETURN, A/C ROUGH AND LINE SET. | PAULO | PAULO | | HRR | C | 5190818 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HRR | T | 04/28/2016 | PAID (REC#1327035): NOT READY. STILL LACKING FRAMING CLEARANCES TO FIRE PLACE. REST OK. NOTE: FINISHED BASEMENT, DUCT DESIGN, 6" OUTSIDE AIR TO RETURN, A/C ROUGH AND LINE SET. | PAULO | PAULO | | HRR | T | 5187164 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HRR | P | 04/27/2016 | ON MAIN FLOOR CEILING B-VENT IS DOES NOT MEET INSULATION CLEARANCE ( IF THIS AREA IS GOING TO BE INSULATED THEN YOU NEED A SHIELD, UP STAIRS FIREPLACE DOES NOT HAVE FRAMING CLEARANCE, LAUNDRY ROOM MAKE UP AIR FRAME IS MISSING, TOP OF SUPPLY AIR PLENUM IS NOT SEALED, S/A IN REC. ROOM MISSING.
NOTE:DUCT DESIGN, 6 INCH OUT SIDE AIR TO RETURN, BASEMENT ROUGH, A/C ROUGH ( COIL AND LINE SET). PLANS DO NOT SHOW A SUPPLY RUN IN FOYER??? | CHUCKF | CHUCKF | | HRR | P | 5186346 |
MD SERVICE PLUMBING, INC. | HI | C | 04/26/2016 | 1''/fp/furn | JOEL | JOEL | | HI | C | 5184734 |
MD SERVICE PLUMBING, INC. | P= | C | 06/07/2016 | correction made | DICK | DICK | | P= | C | 5217055 |
MD SERVICE PLUMBING, INC. | P= | R | 06/06/2016 | no aav basement lav, note: finished basement, 3/4'' pvb installed | TED | TED | | P= | R | 5215665 |
MD SERVICE PLUMBING, INC. | P= | T | 06/01/2016 | PAID (REC#1333461): not ready | TIM | TIM | | P= | T | 5212313 |
MD SERVICE PLUMBING, INC. | PTO | C | 04/22/2016 | finished basement, aav on basement lav, right side master lav cwv | TED | TED | | PTO | C | 5183099 |
MD SERVICE PLUMBING, INC. | PB | C | 03/14/2016 | | TIM | TIM | | PB | C | 5154355 |