TUSCANY HOMES LLC | B= | C | 04/28/2016 | | BOBF | BOBF | | B= | C | 5187330 |
TUSCANY HOMES LLC | BLA | C | 01/08/2016 | | BOBF | BOBF | | BLA | C | 5113015 |
TUSCANY HOMES LLC | BLA | R | 01/06/2016 | need to seal around light boxes where osb is exposed | BOBF | BOBF | | BLA | R | 5111466 |
TUSCANY HOMES LLC | BFR | C | 12/23/2015 | eng letter for girder P on file | BOBF | BOBF | | BFR | C | 5105272 |
TUSCANY HOMES LLC | BIN | C | 12/23/2015 | | BOBF | BOBF | | BIN | C | 5105271 |
TUSCANY HOMES LLC | BFR | P | 12/16/2015 | OK to insulate / post down under south end of P girder / need stamped truss repair for P girder on south end where leg is cut off / plans call 2 HTS20's at all bearing points for all girders unless otherwise noted / plans call 6 SDS screws 12" OC at deck ledger | DANE | DANE | | BFR | P | 5099855 |
TUSCANY HOMES LLC | BTR | C | 12/03/2015 | | DALE | DALE | | BTR | C | 5090966 |
TUSCANY HOMES LLC | BTR | R | 12/01/2015 | full of snow | DALE | DALE | | BTR | R | 5089284 |
TUSCANY HOMES LLC | BFD | C | 10/06/2015 | 3000 , useable, positive, 1.5 | TOMG | TOMG | | BFD | C | 5051643 |
TUSCANY HOMES LLC | BFN | C | 10/06/2015 | Received letter | TOMG | TOMG | | BFN | C | 5051542 |
TUSCANY HOMES LLC | BFI | C | 10/06/2015 | | TOMG | TOMG | | BFI | C | 5051539 |
TUSCANY HOMES LLC | BFT | C | 10/06/2015 | Received letter | TOMG | TOMG | | BFT | C | 5051537 |
TUSCANY HOMES LLC | BFT | P | 10/06/2015 | AUTHORIZED INSPECTION BY ENGINEER | TERRI | TERRI | TERRI | BFT | P | 5051127 |
TUSCANY HOMES LLC | BFN | P | 10/06/2015 | AUTHORIZED INSPECTION BY ENGINEER | TERRI | TERRI | TERRI | BFN | P | 5051126 |
ROWAN ELECTRIC LLC | E= | C | 04/26/2016 | | CRAIG | CRAIG | | E= | C | 5184575 |
ROWAN ELECTRIC LLC | E= | P | 04/08/2016 | install main breaker at pool panel, pothole feeder topool panel, non-ic cans above fireplace need to be removed or installed with correct clearance from combustibles and insulation (can't have insulation above or within 3" of cans)---------- a/c's have been relocated to 200 amp sub-panel--------- hot tub not going to be wired and contractor knows of permit requirements if hot tub is wired | MATTHEW | MATTHEW | | E= | P | 5173384 |
ROWAN ELECTRIC LLC | E= | R | 04/07/2016 | label service disconnects (service disconnect 1 of 2 and service disconnect 2 of 2), leave ladder on site to check lox volt xfmr's above oven, non-ic can at fireplace installed against combustibles needs to be relocated (need all cans lowered), closet light in upper bedroom needs clearance corrected, ground powder room light, clean up panel schedules--------------- I still haven't received a call and I don't know what's happening with the pool and pool panel--------- I haven't received a load calc on 100 amp panel-------- there is a hot tub on back patio?---------- call me 327-2952 | MATTHEW | MATTHEW | | E= | R | 5172263 |
ROWAN ELECTRIC LLC | E= | R | 04/05/2016 | label service disconnects, label circuit 8 at service, label a/c's inside disconnect, #12 too small for 28.1 MCA, need tr outlet in master closet, need location for all low volt xfmr's, lower non-ic rated cans around fireplace, correct closet light clearance in upper guest bedroom, ground powder room light, gfci protect outlet back side of wet bar, gfci protect outlet for low volt xfmrs in mech room (need to be in readily accessible location), protect nm ran on top of floor plate in mech room, afci all kitchen circuits, provide load calc on 100 amp sub-panel, label all breakers in 100 amp sub-panel, label switches at: master closet and 3 switches in kitchen (low volt?) and at end of hall by garage ------------------- no power to pool panel?; call me 327-2952------------------- (2) 30 amp a/c's | MATTHEW | MATTHEW | | E= | R | 5170337 |
ROWAN ELECTRIC LLC | ER | C | 12/15/2015 | correction not made pool panel ------------ check lights by fire place not installed in shelving at this time | CRAIG | CRAIG | | ER | C | 5099499 |
ROWAN ELECTRIC LLC | ES | C | 12/15/2015 | Residential Underground: 2 - 200 amp 3/w new res seal meter | CRAIG | CRAIG | | ES | C | 5099497 |
ROWAN ELECTRIC LLC | EUG | P | 12/14/2015 | 4/0 al service laterals ok; need approved wiring method to pool panel | MATTHEW | MATTHEW | | EUG | P | 5098231 |
ROWAN ELECTRIC LLC | ES | R | 12/14/2015 | see rough------------- sub-panels ok, no mcc's, no vac, finished basement | MATTHEW | MATTHEW | | ES | R | 5098229 |
ROWAN ELECTRIC LLC | ER | R | 12/14/2015 | complete re-inspect: partial list: add outlet in bedroom by garage, nm coiled in dining room ceiling, deck outlets on small appliance circuit, add outlet left of main level fireplace, nm not made to box in shelves by main level fireplace, can light above stairs hanging, missing wire to well head?, correct spacing in big room behind sub-panels, ground pan boxes, wire basement fireplace, add ouitlet left of basement fireplace, grounding electrode conductor cut behind service panel, need approved wiring method to pool panel | MATTHEW | MATTHEW | | ER | R | 5098227 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | H= | C | 03/09/2016 | Finished basement, high/low transfer in wall, full a/c x2, no mantels. | MICHAELS | MICHAELS | | H= | C | 5151392 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HC | C | 12/09/2015 | RELEASE METER | MICHAELS | MICHAELS | | HC | C | 5095548 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HRR | C | 12/09/2015 | Correction made. | MICHAELS | MICHAELS | | HRR | C | 5095547 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HRR | P | 12/08/2015 | Insulation shield not tall enough, rest ok. Note: finished basement, 6" osa x2, a/c rough(coil and lineset)x2, direct vent furnace x2. | MICHAELS | MICHAELS | | HRR | P | 5094441 |
KROME GAS AND PLUMBING CO., INC. | HI | C | 11/30/2015 | 10# test ok. | MICHAELS | MICHAELS | | HI | C | 5088511 |
KROME GAS AND PLUMBING CO., INC. | HI | P | 11/25/2015 | Low test. 2" main to 2-furn, 2-w/h, 3-fp, range, bbq. | MICHAELS | MICHAELS | | HI | P | 5087711 |
FAIRWAY PLUMBING & HEATING, INC. | P= | C | 04/04/2016 | NOTE : FINISHED BASEMENT , TEMPERING UNDER MASTER LAV FOR TUB , RP INSTALLED IN MEC FOR POOL , PVB INSTALLED | GABE | GABE | | P= | C | 5169001 |
FAIRWAY PLUMBING & HEATING, INC. | PTO | C | 12/11/2015 | NOTE : AAV AT LAV THROUGH OUT , TEMPERING AT FINAL , FINISHED BASEMENT , NO IRRIGATION , WILL NEED BACK FLOW FOR POOL WATER BY FINAL | GABE | GABE | | PTO | C | 5097456 |
HOMEOWNER | PWO | C | 12/04/2015 | NEED POTABLE WATER CERT BY FINAL | GABE | GABE | | PWO | C | 5092144 |
FAIRWAY PLUMBING & HEATING, INC. | PB | C | 10/14/2015 | H2O RUN UNDER FOOTER , BACK FLOW REQUIRED FOR WATER TO OUT BUILDING/YARD HYDRANT , | GABE | GABE | | PB | C | 5057520 |