HOMEOWNER | B= | C | 03/22/2016 | | ERICR | ERICR | | B= | C | 5160302 |
HOMEOWNER | B= | P | 02/18/2016 | Has partial fire final need final completed / need city engineering inspection / Need to inspect retaining wall when completed / need engineering for retaining wall if over four feet / need insulation certificate / 14" blown in attic / basement unfinished -- Schedule a new Building Final when above items are complete. Additional Inspections Required (computer generated): External Agency Inspection F= by FIREDEPT is not Completed yet (Contact: 385-5982, x2), External Agency Inspection N= by ENGINEERING is not Completed yet (Contact: City Engineering Inspections 719-385-5977). | ERICR | ERICR | | B= | P | 5137186 |
HOMEOWNER | BLA | C | 01/19/2016 | | DAN | DAN | | BLA | C | 5118291 |
HOMEOWNER | BIN | C | 12/16/2015 | | DAN | DAN | | BIN | C | 5100203 |
HOMEOWNER | BIN | R | 12/15/2015 | still missing insulation at the basement stair landing exterior rim | BRIANB | BRIANB | | BIN | R | 5098880 |
HOMEOWNER | BFR | C | 12/15/2015 | dbl 2x4 posts at the rear covered patio okay per engineering letter received | BRIANB | BRIANB | | BFR | C | 5098877 |
HOMEOWNER | BIN | P | 12/14/2015 | missing insulation at the basement stair landing exterior rim | BRIANB | BRIANB | | BIN | P | 5098699 |
HOMEOWNER | BFR | P | 12/14/2015 | missing 4x4 post(s) at the rear covered patio - per engineering letter received / engineering letter received for framing modification / all other corrections okay | BRIANB | BRIANB | | BFR | P | 5098679 |
HOMEOWNER | BFR | P | 12/10/2015 | need engineering letter for (2) rear covered patio corner posts not on approved plans - dbl 2x4 installed / need engineering letter for steel beams installed in floor framing in lieu of 11 7/8' LVL per plan / need engineering letter for dbl 11 7/8" framing modifications at top of basement stairs not per plan / wood block installed at rear beam pocket / okay to insulate / basement rough frame only / no deck | BRIANB | BRIANB | | BFR | P | 5096696 |
HOMEOWNER | BFD | C | 12/10/2015 | engineering letter of inspection received / soils letter received / all paper work received | BRIANB | BRIANB | | BFD | C | 5096695 |
HOMEOWNER | BFN | C | 12/10/2015 | engineering letter of inspection received / eufer documented | BRIANB | BRIANB | | BFN | C | 5096694 |
HOMEOWNER | BFT | C | 12/10/2015 | engineering letter of inspection received | BRIANB | BRIANB | | BFT | C | 5096693 |
HOMEOWNER | BSP | P | 12/02/2015 | PLAN SPLICE: (No Fee) by: SHELLEY for Construction: Removed basement finish (FRAMED ONLY), and corrected square footage. | SHELLEY | SHELLEY | | BSP | P | 5089883 |
HOMEOWNER | BFD | P | 09/24/2015 | AUTHORIZED INSPECTION BY ENGINEER | MINDY | MINDY | MINDY | BFD | P | 5043509 |
HOMEOWNER | BFT | P | 09/24/2015 | AUTHORIZED INSPECTION BY ENGINEER | MINDY | MINDY | MINDY | BFT | P | 5043508 |
HOMEOWNER | BFN | P | 09/24/2015 | AUTHORIZED INSPECTION BY ENGINEER | MINDY | MINDY | MINDY | BFN | P | 5043507 |
HOMERUN ELECTRONICS, INC. | E= | C | 02/17/2016 | a/c installed, unfinished basement. | BRET | BRET | | E= | C | 5136425 |
HOMERUN ELECTRONICS, INC. | ES | C | 12/08/2015 | Residential Underground: NEW 200 AMP SERVICE | MIKEC | MIKEC | | ES | C | 5094614 |
HOMERUN ELECTRONICS, INC. | ER | C | 12/08/2015 | | MIKEC | MIKEC | | ER | C | 5094528 |
THE FURNACE GUY HEATING & COOLING | H= | C | 02/17/2016 | 2 - SUPPLYS HAVE BEEN INSTALLED IN THE DUCTWORK. | JEFFB | JEFFB | | H= | C | 5136051 |
THE FURNACE GUY HEATING & COOLING | H= | P | 02/16/2016 | THE BASEMENT HAS A RETURN BUT NEEDS 2 - SUPPLY ALSO. NOTES: THE A/C IS COMPLETE. | JEFFB | JEFFB | | H= | P | 5134945 |
THE FURNACE GUY HEATING & COOLING | HRR | C | 12/09/2015 | Corrections made. Equipment change letter received. | STEVEC | STEVEC | | HRR | C | 5095590 |
THE FURNACE GUY HEATING & COOLING | HRR | P | 12/08/2015 | Fireplace vent lacks clearance from roofing paper, use provided tabs at fireplace to secure to framing, heat run basement bottom of duct work needs to be sleeved with sheet metal/thermal panning cannot be used to for ducting supply runs. Note: duct design, A/C coil and line-set, basement frame only, check venting connections at water heater, transfer to laundry and provide equipment change letter by final. | STEVEC | STEVEC | | HRR | P | 5094539 |
O.M.A.G.M., INC. | HC | C | 12/08/2015 | RELEASE METER | STEVEC | STEVEC | | HC | C | 5094386 |
O.M.A.G.M., INC. | HI | C | 12/08/2015 | 10# test o.k. 1"1/4 main, furnace, water heater, cook-top, fireplace, dryer. bbq. | STEVEC | STEVEC | | HI | C | 5094382 |
RELIABLE PLUMBING & HEATING | P= | C | 02/17/2016 | corrections made. | TAYLOR | TAYLOR | | P= | C | 5135707 |
RELIABLE PLUMBING & HEATING | P= | P | 02/16/2016 | need hammer arrestor at dishwasher, aav at hall bath lav, drain 90 at pvb, install mixing valve at master tub rough, need 4 inches from top of drain to bottom of all aav's, rest ok, note: base rough plumbing and framing only in basement. | TAYLOR | TAYLOR | | P= | P | 5135011 |
RELIABLE PLUMBING & HEATING | PTO | C | 12/09/2015 | corrections made. | TAYLOR | TAYLOR | | PTO | C | 5095227 |
RELIABLE PLUMBING & HEATING | PTO | P | 12/08/2015 | low test dwv at kitchen, undersized wet vent for master bath, re-grade kitchen drain, rest ok, aav's at both lavs in master, hall bath lav, kitchen, check water heater, meter, and mixing valve for master tub at final, note: base rough plumbing and framing only in basement. | TAYLOR | TAYLOR | | PTO | P | 5093820 |
RELIABLE PLUMBING & HEATING | PB | C | 11/02/2015 | | TAYLOR | TAYLOR | | PB | C | 5070632 |