SCOTT BUILDING, INC | B= | C | 04/27/2017 | | JUSTINL | JUSTINL | | B= | C | 5488678 |
SCOTT BUILDING, INC | B= | P | 04/26/2017 | need ladder at attic access -- Schedule a new Building Final when above items are complete. | DALE | DALE | | B= | P | 5488025 |
SCOTT BUILDING, INC | BSP | P | 03/16/2017 | Rear porch post was visually inspected through an opening provided by the contractor and the material is of code compliant decay resistant material and verified by Bert W | BERTW | BERTW | | BSP | P | 5442657 |
SCOTT BUILDING, INC | B16 | P | 03/08/2017 | call with Steve Scott from office / reviewed wood columns and columns to be of natural decay resistance or approved pressure-preservative treated wood / Steve will expose the rear porch post for re-inspection and recall inspection | BRIANB | BRIANB | | B16 | P | 5434353 |
SCOTT BUILDING, INC | BSP | R | 03/06/2017 | **NOTE TO INSPECTOR, ** VERIFY TREATED POST AT REAR PORCH PER PREVIOUS BSP REJECT. | ROGER | ROGER | | BSP | R | 5431806 |
SCOTT BUILDING, INC | BLA | C | 11/01/2016 | | DALE | DALE | | BLA | C | 5333583 |
SCOTT BUILDING, INC | BIN | C | 09/02/2016 | | BRIANB | BRIANB | | BIN | C | 5285198 |
SCOTT BUILDING, INC | BFR | C | 09/02/2016 | corrections okay / letter for truss repairs and structural modifications received | BRIANB | BRIANB | | BFR | C | 5285190 |
SCOTT BUILDING, INC | BFR | P | 08/16/2016 | Need Engineer Fix for: damaged bottom cord of truss G1 at 2car / anchor bolts incomplete at plate breaks in garage / hangers for triple BCI in unfinished area of basement not on approved plans and nails incomplete / letter for C1 truss repairs received / okay to insulate | BRIANB | BRIANB | | BFR | P | 5270520 |
SCOTT BUILDING, INC | BSP | R | 06/14/2016 | need treated post at rear porch | DALE | DALE | | BSP | R | 5222425 |
SCOTT BUILDING, INC | BSP | P | 06/07/2016 | porch frames ok, rear porch post not in | DALE | DALE | | BSP | P | 5216922 |
SCOTT BUILDING, INC | BSP | P | 06/07/2016 | narrow braced wall ok | DALE | DALE | | BSP | P | 5216921 |
SCOTT BUILDING, INC | BFD | C | 12/07/2015 | | DALE | DALE | | BFD | C | 5093533 |
SCOTT BUILDING, INC | BFN | C | 12/07/2015 | ok per eng. / all paperwork on file / float | DALE | DALE | | BFN | C | 5093532 |
SCOTT BUILDING, INC | BFT | C | 12/07/2015 | ok per eng. | DALE | DALE | | BFT | C | 5093528 |
SCOTT BUILDING, INC | BFT | P | 10/21/2015 | AUTHORIZED INSPECTION BY ENGINEER | JANE | JANE | JANE | BFT | P | 5062435 |
SCOTT BUILDING, INC | BFN | P | 10/21/2015 | AUTHORIZED INSPECTION BY ENGINEER | JANE | JANE | JANE | BFN | P | 5062434 |
ROWAN ELECTRIC LLC | EP | C | 04/25/2017 | 100 amp 4/w to sub panel ok | CRAIG | CRAIG | | EP | C | 5487275 |
ROWAN ELECTRIC LLC | E= | C | 04/25/2017 | | CRAIG | CRAIG | | E= | C | 5486982 |
ROWAN ELECTRIC LLC | E= | R | 04/19/2017 | I inspected exterior, garage and main level only-------- contractor needs to check house before recalling: partial list: need front exterior outlet, need disconnects for ovens, afci garage light, afci whole hose fan, trim all shower lights, ground front bedroom and master switches, 1/2 switched outlet in front bedroom is wired wrong, gfci's for spa need to be readily accessible and outlets need to face opening, single outlet only above tub, install panel screws | MATTHEW | MATTHEW | | E= | R | 5480450 |
ROWAN ELECTRIC LLC | ER | C | 08/11/2016 | | BRET | BRET | | ER | C | 5267225 |
ROWAN ELECTRIC LLC | ER | R | 08/10/2016 | correction not made from previous inspection --------------- note above master tub single outlet needs to be gfi ok per Matt ----------------- verify in dining room built in cabinets on rights side | CRAIG | CRAIG | | ER | R | 5266318 |
ROWAN ELECTRIC LLC | ES | C | 08/09/2016 | Residential Underground: 200 amp 3/w: new res------ meter is set; need seal | MATTHEW | MATTHEW | | ES | C | 5264986 |
ROWAN ELECTRIC LLC | ER | R | 08/09/2016 | trim attic and add light at whole house fan------------ finished basement, no vac, no mcc's, non-ir ufer--------- service rated transfer switch, 200 amp sub-panel in garage, 100 amp sub-panel in garage | MATTHEW | MATTHEW | | ER | R | 5264983 |
ROWAN ELECTRIC LLC | EUG | C | 05/11/2016 | 4/0 al service lateral ok | MATTHEW | MATTHEW | | EUG | C | 5197199 |
REGIONAL HEATING AND AIR CONDITIONING, INC. | H= | C | 04/18/2017 | Note-- direct vent boiler. | JEFFL | JEFFL | | H= | C | 5479368 |
J.J. BROOME PLUMBING AND HEATING LLC | HV | C | 08/01/2016 | Vent ok | JEFFL | JEFFL | | HV | C | 5258609 |
J.J. BROOME PLUMBING AND HEATING LLC | HWP+ | C | 07/25/2016 | 10# test ok. | JEFFL | JEFFL | | HWP+ | C | 5253158 |
REGIONAL HEATING AND AIR CONDITIONING, INC. | HRR | C | 06/24/2016 | Vents and exhaust ok. In floor heat. | JEFFL | JEFFL | | HRR | C | 5231148 |
REGIONAL HEATING AND AIR CONDITIONING, INC. | HRR | L | 06/20/2016 | Home is locked. | JEFFL | JEFFL | | HRR | L | 5226578 |
L & L GAS SHOP, LLC. | HC | C | 06/10/2016 | RELEASE METER | JEFFL | JEFFL | | HC | C | 5220222 |
L & L GAS SHOP, LLC. | HI | C | 06/10/2016 | 10# test ok. Notes-- 1 1/4'' main.. 1 boiler.. 1 cook top.. 1 fp.. 1 gas heat stove. 1 bbq | JEFFL | JEFFL | | HI | C | 5220216 |
L & L GAS SHOP, LLC. | HO | C | 05/13/2016 | Pressure test ok. Notes-- 75' of 1'' installed from meter to fire pit. | JEFFL | JEFFL | | HO | C | 5199432 |
J.J. BROOME PLUMBING AND HEATING LLC | HWP | P | 05/04/2016 | Main level HWP ok. OK to cover. | JEFFL | JEFFL | | HWP | P | 5192099 |
J.J. BROOME PLUMBING AND HEATING LLC | HWP | P | 02/03/2016 | 60 LB. pressure test ok in basement. OK to cover. | JEFFL | JEFFL | | HWP | P | 5127770 |
J.J. BROOME PLUMBING AND HEATING LLC | P= | C | 04/24/2017 | Certification of potable water to scanning. | CRADE | CRADE | | P= | C | 5484541 |
J.J. BROOME PLUMBING AND HEATING LLC | P= | P | 04/19/2017 | Need certificate of potable water.Rest ok.Note:finished basement,mixing valve at master closet. | CRADE | CRADE | | P= | P | 5480377 |
J.J. BROOME PLUMBING AND HEATING LLC | PTO+ | C | 07/25/2016 | | TIM | TIM | | PTO+ | C | 5252709 |
SCOTT BUILDING, INC | PWO | C | 05/11/2016 | | TIM | TIM | | PWO | C | 5197234 |
J.J. BROOME PLUMBING AND HEATING LLC | PTO | C | 05/03/2016 | | TIM | TIM | | PTO | C | 5190897 |
J.J. BROOME PLUMBING AND HEATING LLC | PB | C | 01/26/2016 | | TIM | TIM | | PB | C | 5123405 |