GUARINO CONSTRUCTION, LLC | B= | C | 12/12/2016 | Plumbing final complete | DAKOTAB | DAKOTAB | | B= | C | 5365040 |
GUARINO CONSTRUCTION, LLC | B= | P | 12/09/2016 | 3/4 finished basement -- AC installed -- Rear deck. Additional Inspections Required (computer generated): Plumbing Final Inspection is not Completed yet. | DAKOTAB | DAKOTAB | | B= | P | 5364902 |
GUARINO CONSTRUCTION, LLC | BIN | C | 12/09/2016 | BFR complete 7/15 | DAKOTAB | DAKOTAB | | BIN | C | 5364899 |
GUARINO CONSTRUCTION, LLC | BSP | P | 12/08/2016 | PLAN SPLICE: (No Fee) by: JUSTINC for Mechanical: Revised heat calcs and hydronic floor plan | JUSTINC | JUSTINC | | BSP | P | 5363161 |
GUARINO CONSTRUCTION, LLC | B16 | C | 12/05/2016 | QUESTION IF PLAN REVIEW IS NEEDED FOR BASEMENT ADDITION OF OVER HEAD DOOR. PLANS ARE BEING BROUGHT BACK FOR NEW HEAT CALC'S DUE TO CHANGE ADDING OVER HEAD DOOR IN BASEMENT. | JON | JON | | B16 | C | 5359683 |
GUARINO CONSTRUCTION, LLC | BSP | T | 09/16/2016 | PAID (REC#1361749) PLAN SPLICE FEE: $50 by: JUSTINC for Mechanical: Revised layout and associated heat calcs | JUSTINC | JUSTINC | | BSP | T | 5295687 |
GUARINO CONSTRUCTION, LLC | BLA | C | 07/25/2016 | | SCOTTS | SCOTTS | | BLA | C | 5253152 |
GUARINO CONSTRUCTION, LLC | BFR | C | 07/15/2016 | joists ok | SCOTTS | SCOTTS | | BFR | C | 5245754 |
GUARINO CONSTRUCTION, LLC | BIN | P | 07/14/2016 | Complete BFR -- Insulation OK | DAKOTAB | DAKOTAB | | BIN | P | 5245568 |
GUARINO CONSTRUCTION, LLC | BFR | P | 07/12/2016 | need engineer letter or show equivalent for BCI joists instead of TJI -- rest ok -- truss corrections complete -- joist fix at basement window on file | SCOTTS | SCOTTS | | BFR | P | 5243047 |
GUARINO CONSTRUCTION, LLC | BSP | R | 06/28/2016 | truss inspection / C1 2ply missing TBE6 and 2nd HTS20 in garage / missing 2x6 bearing block at 3ply J2 truss at music room / need to finish securing THGQ3 hanger at 3 ply J2 truss / K1 2ply truss missing 2nd HTS20 strap at east wall | BRIANB | BRIANB | | BSP | R | 5233419 |
GUARINO CONSTRUCTION, LLC | BIN | P | 06/28/2016 | Qualified third party energy inspection documentation must be presented at time of final building (B=) inspection | INTERNET | INTERNET | | BIN | P | 5232266 |
GUARINO CONSTRUCTION, LLC | BSP | P | 06/21/2016 | porch frame and posts ok | DALE | DALE | | BSP | P | 5227735 |
GUARINO CONSTRUCTION, LLC | BSP | T | 05/02/2016 | PAID (REC#1327134) PLAN SPLICE FEE: $50 by: DANM for Construction: Timber frame added and roof trusses redesigned | DANM | DANM | | BSP | T | 5190069 |
GUARINO CONSTRUCTION, LLC | BSP | P | 12/18/2015 | still need foundation design | BOBF | BOBF | | BSP | P | 5102006 |
GUARINO CONSTRUCTION, LLC | BSP | P | 12/18/2015 | foundation design on file | DANE | DANE | | BSP | P | 5101377 |
GUARINO CONSTRUCTION, LLC | BSP | P | 12/18/2015 | open hole on file / still need foundation design | BOBF | BOBF | | BSP | P | 5101368 |
GUARINO CONSTRUCTION, LLC | BFT | C | 12/18/2015 | eng letter for footing on file | BOBF | BOBF | | BFT | C | 5101365 |
GUARINO CONSTRUCTION, LLC | BFN | C | 12/18/2015 | eng letter for steel and eufer on file | BOBF | BOBF | | BFN | C | 5101364 |
GUARINO CONSTRUCTION, LLC | BFD | C | 12/18/2015 | eng letter for drain on file | BOBF | BOBF | | BFD | C | 5101361 |
GUARINO CONSTRUCTION, LLC | BFT | P | 11/04/2015 | AUTHORIZED INSPECTION BY ENGINEER | MINDY | MINDY | MINDY | BFT | P | 5072912 |
GUARINO CONSTRUCTION, LLC | BFD | P | 11/04/2015 | AUTHORIZED INSPECTION BY ENGINEER | MINDY | MINDY | MINDY | BFD | P | 5072913 |
GUARINO CONSTRUCTION, LLC | BFN | P | 11/04/2015 | AUTHORIZED INSPECTION BY ENGINEER | MINDY | MINDY | MINDY | BFN | P | 5072911 |
MESA ELECTRIC, LLC. | E= | C | 12/05/2016 | | BRET | BRET | | E= | C | 5360919 |
MESA ELECTRIC, LLC. | E= | R | 11/30/2016 | j-boxes behind coach lights are open to the weather, no power to lower exterior light right of front door, install inter-system bond terminal, switches in front room are not showing grounded, what is the third switch in hall by powder room controlling?, provide paperwork and ladder for low volt xfmrs in pantry, need breaker lock for double oven, need 2 screws in industrial cover for disposal, provide test lights for soffit outlets, label circuit 23 in service panel, (2) 50 amp outlets for car chargers will over load 100 amp sub-panel and maybe 200 amp service panel (provide load calc's), gfci protect outlet within 6' of master bedroom sink, center master bath light not working, ground switch for back basement hall light, gfci protect outlet within 6' of basement bath sink, protect nm over top in unfinished area----------------- 30 amp a/c and hot tub pre-wire | MATTHEW | MATTHEW | | E= | R | 5356918 |
MESA ELECTRIC, LLC. | ER | C | 07/07/2016 | | MATTHEW | MATTHEW | | ER | C | 5239659 |
MESA ELECTRIC, LLC. | ER | R | 07/06/2016 | need to add outlets: in master bedroom at future fireplace, in foyer at shadow box wall, and in rec room within 6' from archway into bedroom, ground basement bath pan box, feeders in garage sub-panel are loose---------- finished basement, 6-3nm to cooking and hot tub stub, no mcc's, 120v vac installed, non-ir ufer | MATTHEW | MATTHEW | | ER | R | 5238479 |
MESA ELECTRIC, LLC. | ES | C | 05/25/2016 | Residential Underground: 200 amp 3/w new res seal meter | CRAIG | CRAIG | | ES | C | 5208373 |
MESA ELECTRIC, LLC. | EUG | C | 05/25/2016 | 3/w 350 mcm al from splice to house ok from splice to meter is existing | CRAIG | CRAIG | | EUG | C | 5208369 |
MESA ELECTRIC, LLC. | ESL | C | 04/29/2016 | 1 basement floor box | MATTHEW | MATTHEW | | ESL | C | 5188191 |
PREMIER MECHANICAL | H= | C | 12/08/2016 | Corrections made. | JACK | JACK | | H= | C | 5363176 |
PREMIER MECHANICAL | H16 | C | 12/05/2016 | DUCT PLANS WERE CHANGED AND SPLICE WAS ADDED IN BDA. WORKED WITH CONTRACTOR TO FIND NEW HEAT CALC'S FOR UP SIZED BOILER TO ACCOMMODATE NEW LOAD WHERE OVER HEAD DOOR WAS ADDED IN BASEMENT. | JON | JON | | H16 | C | 5359684 |
PREMIER MECHANICAL | H= | P | 12/02/2016 | Spliced plans on sire ok for duct design, but still need equipment cert for air handler. Rest ok. Note: Finished basement direct vent boiler, no outside air. | MARK | MARK | | H= | P | 5358672 |
PREMIER MECHANICAL | HRR | C | 07/07/2016 | One supply in master and one supply in upstairs powder still missing. Please leave equipment cert on sight for re inspection. Update-- 7/11-- 2 heat runs up sized in master and one eliminated. Heat run in powder eliminated. Duct design to match at final. | JEFFL | JEFFL | | HRR | C | 5240060 |
PREMIER MECHANICAL | HC | C | 07/07/2016 | RELEASE METER | JEFFL | JEFFL | | HC | C | 5241366 |
PREMIER MECHANICAL | HI | C | 07/05/2016 | 10 LB GAS TEST GOOD. 1 1/2'' MAIN BOILER RANGE DRYER. FIREPLACE TWO STUBS MASTER BEDROOM GRETCHENS ROOM. TWO OUTDOOR STUBS. | LUKE | LUKE | | HI | C | 5237657 |
PREMIER MECHANICAL | HRR | P | 07/05/2016 | BOILER VENTS NOT COMPLETE TO BOILER AT THIS TIME..NEED TO SEAL RETURN AIR WHERE ANYTHING PENETRATES WIRES PLUMBING. MISSING SUPPLY AIR IN MASTER BED ROOM MISSING SUPPLY AIR IN POWDER ROOM BOTH ON MAIN LEVEL OF HOUSE.. NEED EQUIPMENT CERTIFICATION FOR FURNACE. NOTE: ELECTRIC FURNACE NO A/C NO OUTSIDE AIR. FINISHED BASEMENT. FIREPLACE AND VENT OK ON MAIN LEVEL GREAT ROOM.. | LUKE | LUKE | | HRR | P | 5237648 |
PREMIER MECHANICAL | HWP | P | 05/16/2016 | Pressure test ok. Notes-- basement ok to cover. | JEFFL | JEFFL | | HWP | P | 5200456 |
CASCADE PLUMBING & HEATING | P= | C | 12/05/2016 | received potable water cert | TIM | TIM | | P= | C | 5359599 |
CASCADE PLUMBING & HEATING | P= | C | 12/02/2016 | | TIM | TIM | | P= | C | 5359090 |
CASCADE PLUMBING & HEATING | P= | C | 11/30/2016 | | TIM | TIM | | P= | C | 5356540 |
CASCADE PLUMBING & HEATING | PTO | C | 07/11/2016 | | TIM | TIM | | PTO | C | 5241560 |
CASCADE PLUMBING & HEATING | PTO | T | 07/08/2016 | PAID (REC#1340764) additional trip required still missing boca plates thru out strap and grade to code thru out, need room for full thick insulation behind washer trap, test all piping thru out re-inspect all | TIM | TIM | | PTO | T | 5240302 |
CASCADE PLUMBING & HEATING | PTO | R | 07/07/2016 | should be trip fee nothing corrected plumb to code | TIM | TIM | | PTO | R | 5239491 |
CASCADE PLUMBING & HEATING | PTO | T | 07/06/2016 | PAID (REC#1340167) not ready to many items, low test thru out test all wtr, boca plates missing thru out, strap to code thru out...stopped inspection re-inspect all | TIM | TIM | | PTO | T | 5238192 |
CASCADE PLUMBING & HEATING | PTO | R | 07/05/2016 | not ready, reinsect all | TED | TED | | PTO | R | 5237419 |
CASCADE PLUMBING & HEATING | PB | C | 04/08/2016 | | TIM | TIM | | PB | C | 5173338 |