ROBERT SCOTT GENERAL CONTRACTORS, INC. | B= | C | 05/27/2016 | corrections complete | ERICR | ERICR | | B= | C | 5210143 |
ROBERT SCOTT GENERAL CONTRACTORS, INC. | B= | P | 05/25/2016 | need to have landing at back door complying with RBC 303.4.16 need an 18" landing at back door -- Schedule a new Building Final when above items are complete. | ERICR | ERICR | | B= | P | 5208454 |
ROBERT SCOTT GENERAL CONTRACTORS, INC. | BIN | C | 03/14/2016 | | ERICR | ERICR | | BIN | C | 5154128 |
ROBERT SCOTT GENERAL CONTRACTORS, INC. | BFR | C | 03/14/2016 | corrections completed | ERICR | ERICR | | BFR | C | 5154127 |
ROBERT SCOTT GENERAL CONTRACTORS, INC. | BLA | C | 03/10/2016 | | ERICR | ERICR | | BLA | C | 5152041 |
ROBERT SCOTT GENERAL CONTRACTORS, INC. | BFR | P | 03/10/2016 | Need to glue stub columns and anti roll block on short beam south side of basement / need all hangers on pop out window on kitchen on trusses above window/ fire and draft blocking/ ok to insulate / need vent baffles in attic and tape measures for blown in insulation | ERICR | ERICR | | BFR | P | 5152033 |
ROBERT SCOTT GENERAL CONTRACTORS, INC. | BSP | P | 02/12/2016 | front porch framing OK to cover. | DAN | DAN | | BSP | P | 5133793 |
ROBERT SCOTT GENERAL CONTRACTORS, INC. | BFD | C | 12/21/2015 | drain installed habitable to sump pit / damp proof okay | BRIANB | BRIANB | | BFD | C | 5103106 |
ROBERT SCOTT GENERAL CONTRACTORS, INC. | BFN | C | 12/21/2015 | engineering letter of inspection received / eufer documented / soils letter received / 2400psf / foundation design received | BRIANB | BRIANB | | BFN | C | 5103098 |
ROBERT SCOTT GENERAL CONTRACTORS, INC. | BFT | C | 12/21/2015 | engineering letter of inspection received | BRIANB | BRIANB | | BFT | C | 5103094 |
ROBERT SCOTT GENERAL CONTRACTORS, INC. | BFT | P | 11/13/2015 | AUTHORIZED INSPECTION BY ENGINEER | BPHILLIPS | BPHILLIPS | BPHILLIPS | BFT | P | 5078636 |
ROBERT SCOTT GENERAL CONTRACTORS, INC. | BFN | P | 11/13/2015 | AUTHORIZED INSPECTION BY ENGINEER | BPHILLIPS | BPHILLIPS | BPHILLIPS | BFN | P | 5078635 |
SERVICE FIRST ELECTRIC | E= | C | 04/26/2016 | 15 AMP A.C | MIKEC | MIKEC | | E= | C | 5185070 |
SERVICE FIRST ELECTRIC | ES | C | 03/09/2016 | Residential Underground: 150 amp service new res. | BRET | BRET | | ES | C | 5150991 |
SERVICE FIRST ELECTRIC | ER | C | 03/09/2016 | #6 al to range ,no mcc, no vac, #12 nm a/c rough | BRET | BRET | | ER | C | 5150982 |
GENE'S HEATING AND AIR LLC | H= | C | 05/19/2016 | 2 - 14 X 14 TRANSFER GRILLS, HIGH AND LOW, ARE ON THE MECHANICAL ROOM WALL AND THE A/C IS COMPLETE. | JEFFB | JEFFB | | H= | C | 5202565 |
GENE'S HEATING AND AIR LLC | HC | C | 03/09/2016 | RELEASE METER | JEFFB | JEFFB | | HC | C | 5151232 |
GENE'S HEATING AND AIR LLC | HRR | C | 03/09/2016 | THE DUCT DESIGN IS GOOD. NOTES: NO DOORS TO THE FINISHED BASEMENT, OUTSIDE AIR TO THE RETURN DUCT AND A/C ROUGH - LINES AND COIL | JEFFB | JEFFB | | HRR | C | 5151231 |
KAMPP-L ENTERPRISES, INC. | HI | C | 03/03/2016 | 10 lb test ok, 1 inch main, 1 furnace, 1 water heater, 1 range, 1 fireplace. | TAYLOR | TAYLOR | | HI | C | 5147067 |
KAMPP-L ENTERPRISES, INC. | P= | C | 05/12/2016 | finished basement, no irrigation. | TAYLOR | TAYLOR | | P= | C | 5197709 |
KAMPP-L ENTERPRISES, INC. | PTO | C | 03/03/2016 | finished basement, aav's at powder bath, both lavs in master, kitchen, basement bath. | TAYLOR | TAYLOR | | PTO | C | 5147096 |
KAMPP-L ENTERPRISES, INC. | PB | C | 12/29/2015 | | TAYLOR | TAYLOR | | PB | C | 5106842 |