ROBERT SCOTT GENERAL CONTRACTORS, INC. | B= | C | 08/03/2016 | finished basement / AC installed | ERICR | ERICR | | B= | C | 5260698 |
ROBERT SCOTT GENERAL CONTRACTORS, INC. | BFR | C | 05/06/2016 | corrections completed | ERICR | ERICR | | BFR | C | 5193605 |
ROBERT SCOTT GENERAL CONTRACTORS, INC. | BIN | C | 05/06/2016 | | ERICR | ERICR | | BIN | C | 5193596 |
ROBERT SCOTT GENERAL CONTRACTORS, INC. | BLA | C | 05/04/2016 | | ERICR | ERICR | | BLA | C | 5191821 |
ROBERT SCOTT GENERAL CONTRACTORS, INC. | BFR | P | 05/03/2016 | missing MT12 on double LVL above stairs second floor/ missing 4 H2.5 above front bedroom window / LS 50 in corner of bearing wall holding up rafters above stairs / Need to strap beam into pocket at stairs / Missing 60 d's on north west corner of basement / need draft and firestop/ ok to insulate | ERICR | ERICR | | BFR | P | 5190845 |
ROBERT SCOTT GENERAL CONTRACTORS, INC. | BSP | P | 04/27/2016 | narrow wall ok | ERICR | ERICR | | BSP | P | 5186072 |
ROBERT SCOTT GENERAL CONTRACTORS, INC. | BSP | P | 04/22/2016 | narrow wall need to complete nail pattern / front porch roof and post ok | ERICR | ERICR | | BSP | P | 5182729 |
ROBERT SCOTT GENERAL CONTRACTORS, INC. | BFD | C | 03/04/2016 | | ERICR | ERICR | | BFD | C | 5148047 |
ROBERT SCOTT GENERAL CONTRACTORS, INC. | BFN | C | 03/04/2016 | received engineers stamped letter of observation on placement of foundation | ERICR | ERICR | | BFN | C | 5148039 |
ROBERT SCOTT GENERAL CONTRACTORS, INC. | BFT | C | 03/04/2016 | received stamped open hole observation and soils report / received engineers observation of / footing placement stamped letter / received foundation design / all have a bearing pressure of 2000 psf | ERICR | ERICR | | BFT | C | 5148030 |
ROBERT SCOTT GENERAL CONTRACTORS, INC. | BFN | P | 12/09/2015 | AUTHORIZED INSPECTION BY ENGINEER | BPHILLIPS | BPHILLIPS | BPHILLIPS | BFN | P | 5095524 |
ROBERT SCOTT GENERAL CONTRACTORS, INC. | BFT | P | 12/09/2015 | AUTHORIZED INSPECTION BY ENGINEER | BPHILLIPS | BPHILLIPS | BPHILLIPS | BFT | P | 5095525 |
SERVICE FIRST ELECTRIC | E= | C | 07/01/2016 | 20 AMP A.C | MIKEC | MIKEC | | E= | C | 5236403 |
SERVICE FIRST ELECTRIC | ER | C | 04/29/2016 | NO CEN. VAC | MIKEC | MIKEC | | ER | C | 5188256 |
SERVICE FIRST ELECTRIC | ES | C | 04/29/2016 | Residential Underground: NEW 200 AMP SERVICE | MIKEC | MIKEC | | ES | C | 5188171 |
GENE'S HEATING AND AIR LLC | H= | C | 07/01/2016 | THE A/C IS COMPLETE AND THERE AR 2 - 14 X 14 TRANSFER GRILLS, HIGH AND LOW, ON THE MECHANICAL ROOM WALL. | JEFFB | JEFFB | | H= | C | 5236003 |
GENE'S HEATING AND AIR LLC | HC | C | 05/02/2016 | RELEASE METER | JEFFB | JEFFB | | HC | C | 5189972 |
GENE'S HEATING AND AIR LLC | HRR | C | 05/02/2016 | THE B-VENT CLEARANCE IS GOOD. | JEFFB | JEFFB | | HRR | C | 5189970 |
GENE'S HEATING AND AIR LLC | HRR | P | 04/29/2016 | THE EQUIPMENT CERTIFICATE IS GOOD. THE REGISTER LOCATION IS ALSO GOOD. THE CLEARANCE TO THE B-VENT ON THE SECOND FLOOR IS ONLY 1/4". NOTES: OUTSIDE AIR TO THE RETURN DUCT. | JEFFB | JEFFB | | HRR | P | 5187899 |
GENE'S HEATING AND AIR LLC | HRR | R | 04/28/2016 | NO BLUE PRINTS ON SITE WITH SUPPLY RUNS, RETURNS OR EXHAUST FANS. THE SPEC SHEET I FOUND AND IS MARKED, DOES NOT MATCH THE UNIT INSTALLED. | JEFFB | JEFFB | | HRR | R | 5187200 |
GENE'S HEATING AND AIR LLC | HRR | R | 04/27/2016 | THERE MUST BE A PRINT TO SHOW REGISTER LOCATIONS AND A EQUIPMENT SPEC SHEET. STOPPED INSPECTION. | JEFFB | JEFFB | | HRR | R | 5185871 |
KAMPP-L ENTERPRISES, INC. | HI | C | 04/26/2016 | 10 LB TEST IS OK. 1 1/4" MAIN FOR THE FURNACE, WATER HEATER, RANGE AND 1 - FIREPLACE. | JEFFB | JEFFB | | HI | C | 5185121 |
KAMPP-L ENTERPRISES, INC. | P= | C | 08/02/2016 | corrections made | GABE | GABE | | P= | C | 5259385 |
KAMPP-L ENTERPRISES, INC. | P= | P | 07/28/2016 | need 15 inches from counter top to center of toilet. | TAYLOR | TAYLOR | | P= | P | 5256280 |
KAMPP-L ENTERPRISES, INC. | P= | P | 07/21/2016 | need 15 inches from edge of cabinet to center of toilet at basement bathroom, rest ok, note: no irrigation, finished basement. | TAYLOR | TAYLOR | | P= | P | 5250471 |
KAMPP-L ENTERPRISES, INC. | PTO | C | 04/27/2016 | finished basement, aav's at all lavs. | TAYLOR | TAYLOR | | PTO | C | 5186021 |
KAMPP-L ENTERPRISES, INC. | PB | C | 03/10/2016 | | TAYLOR | TAYLOR | | PB | C | 5152255 |