BLUE RIDGE CONTRACTORS, INC. | B= | C | 01/28/2020 | okay per Bob | NELIDA | NELIDA | | B= | C | 6466930 |
BLUE RIDGE CONTRACTORS, INC. | B= | P | 12/26/2019 | pending completion of fire and zoning, building okay -- Schedule a new Building Final when above items are complete. Additional Inspections Required (computer generated): External Agency Inspection F= by FIREDEPT is not Completed yet (Contact: 385-5982, x2), External Agency Inspection Z= by ZONING is not Completed yet (Contact: 719-385-5982). | BOBF | BOBF | | B= | P | 6437102 |
BLUE RIDGE CONTRACTORS, INC. | B= | P | 06/28/2019 | core and shell final OK pending other required inspections. Additional Inspections Required (computer generated): External Agency Inspection F= by FIREDEPT is not Completed yet (Contact: 385-5982, x2), External Agency Inspection Z= by ZONING is not Completed yet (Contact: 719-385-5982), External Agency Inspection N= by ENGINEERING is not Completed yet (Contact: City Engineering Inspections 719-385-5977), External Agency Inspection HD= by HEALTHDEPT is not Completed yet, LANDMARK PLUMBING & HEATING, INC. Mechanical Final Inspection is not Completed yet. | LONNYS | LONNYS | | B= | P | 6248255 |
BLUE RIDGE CONTRACTORS, INC. | BIN | C | 06/28/2019 | | LONNYS | LONNYS | | BIN | C | 6248252 |
BLUE RIDGE CONTRACTORS, INC. | BFR | C | 06/28/2019 | | LONNYS | LONNYS | | BFR | C | 6248242 |
BLUE RIDGE CONTRACTORS, INC. | BFR | P | 09/13/2018 | Shell framing inspection / observed bolting/steel frame in compliance with plans / UPDATE: framing pending completion of other roughs. | CHUCK | CHUCK | | BFR | P | 5963965 |
BLUE RIDGE CONTRACTORS, INC. | BFN | C | 09/13/2018 | Foundation inspection to close out previous partials / min. soil bearing changed to 1700 psf on corrected sht. S5 (Pg. 106) / no drain required / perimeter grade sloping away from building. | CHUCK | CHUCK | | BFN | C | 5963959 |
BLUE RIDGE CONTRACTORS, INC. | BE | L | 09/11/2018 | Renewed at 9/11/2018 8:22:56 AM | NELIDA | NELIDA | | BE | L | 5960681 |
BLUE RIDGE CONTRACTORS, INC. | BE | L | 02/22/2018 | Renewed at 2/22/2018 11:44:08 AM | NELIDA | NELIDA | | BE | L | 5771352 |
BLUE RIDGE CONTRACTORS, INC. | BE | L | 05/02/2017 | Renewed at 5/2/2017 4:00:09 PM | JANE | JANE | | BE | L | 5493901 |
BLUE RIDGE CONTRACTORS, INC. | BSP | P | 09/02/2016 | 2 foundation stair walls ok | DALE | DALE | | BSP | P | 5284808 |
BLUE RIDGE CONTRACTORS, INC. | BFN | P | 08/17/2016 | 2 remaining wing walls at dock ok | DALE | DALE | | BFN | P | 5271202 |
BLUE RIDGE CONTRACTORS, INC. | BFN | P | 08/04/2016 | wing wall at grid 2 at back ok | DALE | DALE | | BFN | P | 5261791 |
BLUE RIDGE CONTRACTORS, INC. | BFN | P | 08/03/2016 | front retaining wall at 2 ok | DALE | DALE | | BFN | P | 5260429 |
BLUE RIDGE CONTRACTORS, INC. | BFT | P | 07/27/2016 | see S.1 orange all retaining and stair footer except the 2 footers at NE corner | NATHAN | NATHAN | | BFT | P | 5255361 |
BLUE RIDGE CONTRACTORS, INC. | BFN | P | 07/21/2016 | remaining perimeter foundation walls okay / dock, stair, ramp walls and interior pads remaining for inspection / see S1 for details | NATHAN | NATHAN | | BFN | P | 5250561 |
BLUE RIDGE CONTRACTORS, INC. | BFN | P | 07/11/2016 | N line 2-7 okay | NATHAN | NATHAN | | BFN | P | 5241771 |
BLUE RIDGE CONTRACTORS, INC. | BFT | P | 07/11/2016 | C line 3-5 last of footer okay | NATHAN | NATHAN | | BFT | P | 5241766 |
BLUE RIDGE CONTRACTORS, INC. | BFN | P | 06/30/2016 | see sheet S1 for inspection details / walls at N 6.5-9, 9 LINE A-N, A LINE 7-9, C LINE 4.5-7, 7 LINE A-C okay | NATHAN | NATHAN | | BFN | P | 5235175 |
BLUE RIDGE CONTRACTORS, INC. | BFT | P | 06/22/2016 | C line,1 thru 4 ok | BERTW | BERTW | | BFT | P | 5228585 |
BLUE RIDGE CONTRACTORS, INC. | BFT | P | 06/21/2016 | 1 line C thru N,N line 1 thru 9 ok/Revised design for 1700psf bearing capacity is spliced to plan set ok | BERTW | BERTW | | BFT | P | 5227206 |
BLUE RIDGE CONTRACTORS, INC. | BSP | T | 06/16/2016 | PAID (REC#1335925) PLAN SPLICE FEE: $50 by: JIMA for Construction: splice : engineering changes see clouds | JIMA | JIMA | | BSP | T | 5224418 |
BLUE RIDGE CONTRACTORS, INC. | BFT | R | 06/14/2016 | openhole states 2750 psf soils foundation design needs 3000 psf / marked in orange S1 and initialed footer per plan | NATHAN | NATHAN | | BFT | R | 5222330 |
ROCKY MOUNTAIN ELECTRICAL SERVICES INC | E= | C | 06/25/2019 | core / shell only ok | CRAIG | CRAIG | | E= | C | 6242776 |
ROCKY MOUNTAIN ELECTRICAL SERVICES INC | ES | C | 06/06/2019 | Commercial Service: 2 - 200 amp 4/w ok to set meter for units 110 and 120 note ufer ok | CRAIG | CRAIG | | ES | C | 6223013 |
ROCKY MOUNTAIN ELECTRICAL SERVICES INC | ESP | C | 06/03/2019 | ----------------------------ATTENTION: Future Meter releases for units should be noted as 100, 110 and 120 plus house panel. NOT A, B, C--------------------------------------- | DEAN | DEAN | | ESP | C | 6217615 |
ROCKY MOUNTAIN ELECTRICAL SERVICES INC | ER | P | 05/17/2019 | Need to attached to interior finish permit ------------------- walls / hard lid ceiling for 4 bath rooms ok Discussed accessibility requirements with contractor / | CRAIG | CRAIG | | ER | P | 6202574 |
ROCKY MOUNTAIN ELECTRICAL SERVICES INC | ES | P | 05/14/2019 | Commercial Service: 200 amp 4/w to unit 100 only ok to set meter 100 amp 4/w to house panel only ok to set meter | CRAIG | CRAIG | | ES | P | 6198533 |
ROCKY MOUNTAIN ELECTRICAL SERVICES INC | EUG | C | 05/13/2019 | Inspected by CSU | CRAIG | CRAIG | | EUG | C | 6196692 |
ROCKY MOUNTAIN ELECTRICAL SERVICES INC | ES | R | 05/13/2019 | Commercial Service: Not Ready | CRAIG | CRAIG | | ES | R | 6196691 |
ROCKY MOUNTAIN ELECTRICAL SERVICES INC | EE | L | 10/02/2017 | Renewed at 10/2/2017 12:31:44 PM | TERRI | TERRI | | EE | L | 5642197 |
ROCKY MOUNTAIN ELECTRICAL SERVICES INC | ESL | P | 06/28/2016 | ufer insp ok ----- 4/0 braided on east side | TOMC | TOMC | | ESL | P | 5232521 |
ROCKY MOUNTAIN ELECTRICAL SERVICES INC | EUG | R | 06/21/2016 | not ready | TOMC | TOMC | | EUG | R | 5226883 |
LANDMARK PLUMBING AND HEATING, INC. | H= | C | 08/23/2019 | SPLICE FOR GAS PIPING ON FILE | MARKB | MARKB | | H= | C | 6312364 |
LANDMARK PLUMBING AND HEATING, INC. | HSP | P | 07/02/2019 | CALLED MIKE AT LANDMARK. THERE SEEMS TO BE SOME CONFUSING ISSUES WITH GAS PIPING, METER LOCATIONS ON THE SHELL VS THE TENANT FINISH. THE ATTACHED FUTURE SPLICE MUST BE TAKEN TO PLAN REVIEW VIA DALE HOKE | JON | JON | | HSP | P | 6250938 |
ENVIRONMENTAL HEATING & AIR CONDITIONING INC. | H= | C | 06/25/2019 | | MARKB | MARKB | | H= | C | 6243408 |
LANDMARK PLUMBING AND HEATING, INC. | HC | P | 06/12/2019 | OK TO RELEASE METER FOR SUITE 120 ONLY - DESIGN PRESSURE 7" W.C. | MARKB | MARKB | | HC | P | 6229003 |
LANDMARK PLUMBING AND HEATING, INC. | HI | P | 06/12/2019 | 10 PSI PRESSURE TEST FOR SUITE 100 & 120 OK. PIPING FOR SUITE 120 PER PLAN (FINAL CONNECTIONS COMPLETE) Piping for suite 100 does not match core & shell plans or interior finish plans - Will need a plan splice for suite 100 and inspection under finish permit. | MARKB | MARKB | | HI | P | 6228993 |
LANDMARK PLUMBING AND HEATING, INC. | HE | C | 04/16/2019 | | JESSICAM | JESSICAM | | HE | C | 6167496 |
ENVIRONMENTAL HEATING & AIR CONDITIONING INC. | HV | C | 11/06/2018 | UNIT HEATERS AND VENTS INSTALLED PER PLAN SPLICE. AT FINAL - Check vent support and thermostats. | MARKB | MARKB | | HV | C | 6017462 |
LANDMARK PLUMBING AND HEATING, INC. | P= | C | 06/27/2019 | R.P. irrigation backflow installed in meter room | TED | TED | | P= | C | 6245997 |
LANDMARK PLUMBING AND HEATING, INC. | P= | P | 06/25/2019 | need to complete water meter room piping, rest ok | TED | TED | | P= | P | 6242610 |
LANDMARK PLUMBING AND HEATING, INC. | PB | C | 04/19/2019 | test and design ok, water under footer | TED | TED | | PB | C | 6171260 |
ENVIRONMENTAL HEATING & AIR CONDITIONING INC. | XMS | P | 08/21/2019 | PLAN SPLICE: (No Fee) by: JUSTINC for Mechanical: Revised shell gas drawing and unit heaters | JUSTINC | JUSTINC | | XMS | P | 6308611 |
ENVIRONMENTAL HEATING & AIR CONDITIONING INC. | XMS | T | 10/31/2018 | PAID (REC#1552626) PLAN SPLICE FEE: $50 by: DALEH for Mechanical: revised entire sheet | DALEH | DALEH | | XMS | T | 6012097 |