PALACE HOMES, INC. | B= | C | 05/04/2016 | unfinished basement, deck in | DALE | DALE | | B= | C | 5191797 |
PALACE HOMES, INC. | BFR | C | 03/04/2016 | | DALE | DALE | | BFR | C | 5148369 |
PALACE HOMES, INC. | BIN | C | 03/04/2016 | | DALE | DALE | | BIN | C | 5148362 |
PALACE HOMES, INC. | BFR | R | 03/02/2016 | install garage door brackets / brace gables at 6ft and brace every 4ft / ok to insulate | DALE | DALE | | BFR | R | 5146512 |
PALACE HOMES, INC. | BSP | P | 02/12/2016 | narrow braced wall, front and rear porch frame and posts ok | DALE | DALE | | BSP | P | 5133761 |
PALACE HOMES, INC. | BSP | P | 01/27/2016 | rear deck piers ok | DALE | DALE | | BSP | P | 5124574 |
PALACE HOMES, INC. | BFD | C | 01/19/2016 | | DALE | DALE | | BFD | C | 5118762 |
PALACE HOMES, INC. | BFI | C | 01/19/2016 | | DALE | DALE | | BFI | C | 5118749 |
PALACE HOMES, INC. | BFN | C | 01/13/2016 | | DALE | DALE | | BFN | C | 5115505 |
PALACE HOMES, INC. | BFN | P | 01/13/2016 | soils and foundation design | DALE | DALE | | BFN | P | 5114894 |
PALACE HOMES, INC. | BFT | C | 01/06/2016 | including interior pads / ufer in / 3000psf | DALE | DALE | | BFT | C | 5111085 |
PALACE HOMES, INC. | BFT | R | 01/05/2016 | steel not complete / can not have pad on cut | DALE | DALE | | BFT | R | 5110288 |
AKSARBEN ELECTRIC LLC. | E= | C | 04/28/2016 | | CRAIG | CRAIG | | E= | C | 5187369 |
AKSARBEN ELECTRIC LLC. | E= | T | 04/27/2016 | PAID (REC#1326381): gfci outlets within 6' of all sinks | MATTHEW | MATTHEW | | E= | T | 5186296 |
AKSARBEN ELECTRIC LLC. | E= | R | 04/26/2016 | afci protect hood, gfci device at micro needs to be removed and afci/gfci breaker installed, correct closet light clearance in master bedroom, gfci protect all outlets within 6' of any sink, lamp all fixtures | MATTHEW | MATTHEW | | E= | R | 5185197 |
AKSARBEN ELECTRIC LLC. | E= | R | 04/22/2016 | complete re-inspect; partial list: no power to back outlet at garage, afci protect per 2014 NEC; laundry, hood, outlet in kitchen cabinet, label panel correctly, no power to dining room, correct closet light clearance, gfci outlets within 6' of sinks, lamp all fixtures, reverse polarity at well controller, install cover plate at well controller, where is the switch for attic fan; may need to afci protect------------------- complete re-inspect-------------- a/c pre-wire | MATTHEW | MATTHEW | | E= | R | 5183169 |
AKSARBEN ELECTRIC LLC. | ES | C | 03/04/2016 | Residential Underground: 200 amp 3/w new res seal meter | CRAIG | CRAIG | | ES | C | 5148106 |
AKSARBEN ELECTRIC LLC. | ES | R | 03/01/2016 | correct neutral bond in disconnect on pole (lug, remove paint, #4cu) | MATTHEW | MATTHEW | | ES | R | 5145562 |
AKSARBEN ELECTRIC LLC. | ER | C | 03/01/2016 | | MATTHEW | MATTHEW | | ER | C | 5145559 |
AKSARBEN ELECTRIC LLC. | ES | R | 02/29/2016 | see rough | MATTHEW | MATTHEW | | ES | R | 5144462 |
AKSARBEN ELECTRIC LLC. | ER | R | 02/29/2016 | bond neutral at pole disconnect, need main breaker at house panel, add outlet on kitchen 1/2 wall on dining room side, ground pan boxes, make up grounds in all light boxes, remove gfci device in attic, label future basement circuits in basement, is the furnace dedicated? -------- unfinished basement, no vac, irreversible ufer, no mcc's, #6al | MATTHEW | MATTHEW | | ER | R | 5144461 |
AKSARBEN ELECTRIC LLC. | EUG | C | 02/22/2016 | 4/w 4/0 al #4 al grd from panel on pole to house ok | CRAIG | CRAIG | | EUG | C | 5139404 |
AIR CONCEPTS HEATING & COOLING | H= | C | 04/25/2016 | Wiring relocated, final ok. | MARK | MARK | | H= | C | 5183556 |
AIR CONCEPTS HEATING & COOLING | H= | P | 04/22/2016 | Wiring contacting b vent in basement. Rest ok. Notes-- Unfinished basement. AC rough line set only. | JEFFL | JEFFL | | H= | P | 5183071 |
AIR CONCEPTS HEATING & COOLING | HC | C | 03/01/2016 | RELEASE METER | JEFFL | JEFFL | | HC | C | 5145511 |
AIR CONCEPTS HEATING & COOLING | HRR | C | 03/01/2016 | Notes-- unfinished basement.. AC rough line set. OSA to return. Duct design.. | JEFFL | JEFFL | | HRR | C | 5145510 |
SPRINGS GAS, INC. | HI | C | 02/25/2016 | 10 LB. test ok. Notes-- 1 1/4'' main.. 1 furnace.. 1 wh.. 1 bbq.. 1 range | JEFFL | JEFFL | | HI | C | 5142344 |
SPRINGS GAS, INC. | HI | P | 02/24/2016 | Low test. Re inspect all. | JEFFL | JEFFL | | HI | P | 5141041 |
JOLLY PLUMBING & HEATING INC. | P= | C | 04/28/2016 | received potable water cert | TIM | TIM | | P= | C | 5186546 |
JOLLY PLUMBING & HEATING INC. | P= | P | 04/27/2016 | need proof of potable water | TIM | TIM | | P= | P | 5186207 |
JOLLY PLUMBING & HEATING INC. | PTO | C | 02/24/2016 | | TIM | TIM | | PTO | C | 5141526 |
PALACE HOMES, INC. | PWO | C | 02/23/2016 | | TIM | TIM | | PWO | C | 5140329 |
JOLLY PLUMBING & HEATING INC. | PB | C | 01/26/2016 | | TIM | TIM | | PB | C | 5123403 |