STEPHENS AND ASSOCIATES, INC. | B= | C | 06/09/2016 | items corrected. | NATHAN | NATHAN | | B= | C | 5219117 |
STEPHENS AND ASSOCIATES, INC. | B= | P | 06/08/2016 | freeze board at rear cantilevers / front steps over 3/8" difference in run / air barrier at garage truss to interior walls / insulation at rim by sump pump discharge / finished basement with a/c. -- Schedule a new Building Final when above items are complete. | NATHAN | NATHAN | | B= | P | 5217584 |
STEPHENS AND ASSOCIATES, INC. | BLA | C | 05/12/2016 | | NATHAN | NATHAN | | BLA | C | 5198026 |
STEPHENS AND ASSOCIATES, INC. | BFR | C | 05/02/2016 | corrections complete | SCOTTS | SCOTTS | | BFR | C | 5189964 |
STEPHENS AND ASSOCIATES, INC. | BIN | C | 05/02/2016 | | SCOTTS | SCOTTS | | BIN | C | 5189959 |
STEPHENS AND ASSOCIATES, INC. | BFR | P | 04/28/2016 | point load under garage girder both ends and strap wall to plates at same / cut plywood access into 3 car trusses / air barriers / combustibles at B vents / diagonal brace lateral brace / connect plumbing vents / secure monoposts / glue shims /okay to insulate | NATHAN | NATHAN | | BFR | P | 5187220 |
STEPHENS AND ASSOCIATES, INC. | BSP | P | 04/28/2016 | front and rear porch and patio, garage portal frame okay | NATHAN | NATHAN | | BSP | P | 5187212 |
STEPHENS AND ASSOCIATES, INC. | BFD | C | 04/01/2016 | | NATHAN | NATHAN | | BFD | C | 5168138 |
STEPHENS AND ASSOCIATES, INC. | BFD | P | 04/01/2016 | letter addressing cold joint in foundation wall on file. | NATHAN | NATHAN | | BFD | P | 5167612 |
STEPHENS AND ASSOCIATES, INC. | BFD | R | 03/03/2016 | provide engineers letter addressing cold joints through out entire foundation and honey comb on rear of foundation / remove trash and debris from excavation / rest of drain okay to street | GEORGEG | GEORGEG | | BFD | R | 5147505 |
STEPHENS AND ASSOCIATES, INC. | BFD | P | 03/03/2016 | soils report and open excavation on file / 2400 psf / drain habitable / 10% grade at final / 1-1/2" float | GEORGEG | GEORGEG | | BFD | P | 5146718 |
STEPHENS AND ASSOCIATES, INC. | BFT | C | 03/03/2016 | reinforcement letter on file | GEORGEG | GEORGEG | | BFT | C | 5146717 |
STEPHENS AND ASSOCIATES, INC. | BFN | C | 03/03/2016 | foundation design on file | GEORGEG | GEORGEG | | BFN | C | 5146714 |
J2D ELECTRIC, INC. | E= | C | 06/07/2016 | a/c installed---30 amp-- | TIMA | TIMA | | E= | C | 5216792 |
J2D ELECTRIC, INC. | E= | R | 06/06/2016 | need to install a/c breaker,fit dead front to breakers,install panel screws | TIMA | TIMA | | E= | R | 5215660 |
J2D ELECTRIC, INC. | EUG | C | 04/28/2016 | 2/0 urd | TOMC | TOMC | | EUG | C | 5187102 |
J2D ELECTRIC, INC. | ES | C | 04/28/2016 | Residential Underground: 150 amp 3/w new res ok to seal | TOMC | TOMC | | ES | C | 5187095 |
J2D ELECTRIC, INC. | ER | C | 04/25/2016 | corrections made | RANDY | RANDY | | ER | C | 5183502 |
J2D ELECTRIC, INC. | ER | R | 04/22/2016 | wire at bedroom window in basement not stapled,need to pan out air return at bedroom soffit | TIMA | TIMA | | ER | R | 5182982 |
J2D ELECTRIC, INC. | ER | R | 04/21/2016 | wires outside wall in foyer next to ceiling , secure wire under windows in basement ------- 150 , 1 - #6 , 2 - #10 , no mcc , irreversible ufer , no central vac , finished basement | TOMC | TOMC | | ER | R | 5181862 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | H= | C | 06/03/2016 | FINISHED BASEMENT , HI/LO TRANSFER A/C COMPLETE | DAVIDH | DAVIDH | | H= | C | 5214004 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | H= | L | 06/02/2016 | NO ACCESS DUE TO PLANE CRASH | DAVIDH | DAVIDH | | H= | L | 5213366 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HC | C | 04/27/2016 | RELEASE METER | DAVIDH | DAVIDH | | HC | C | 5185964 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HRR | C | 04/27/2016 | FINISHED BASEMENT, 6"OSA, A/C ROUGH | DAVIDH | DAVIDH | | HRR | C | 5185962 |
SPRINGS GAS, INC. | HI | C | 04/22/2016 | 10 LB TEST OK NOTE 1 FURN,W/H AND F/P | DAVIDH | DAVIDH | | HI | C | 5182426 |
SPRINGS GAS, INC. | HI | R | 04/15/2016 | NO FALL PROTECTION UP NO INSPECTION WAIVED TRIP FEE | DAVIDH | DAVIDH | | HI | R | 5177911 |
MD SERVICE PLUMBING, INC. | P= | C | 06/01/2016 | finished basement, pvb installed | DICK | DICK | | P= | C | 5212438 |
MD SERVICE PLUMBING, INC. | PTO | C | 04/22/2016 | finished basement, aav basement lav | DICK | DICK | | PTO | C | 5182423 |
MD SERVICE PLUMBING, INC. | PB | C | 03/21/2016 | complete. | DICK | DICK | | PB | C | 5159247 |
MD SERVICE PLUMBING, INC. | PB | L | 03/18/2016 | field cancelled | DICK | DICK | | PB | L | 5158055 |