MASTER BILT HOMES, INC. | B= | C | 07/15/2016 | corrections made | SCOTTS | SCOTTS | | B= | C | 5246235 |
MASTER BILT HOMES, INC. | B= | P | 06/21/2016 | Temp CO: pending building final ( Expires: 7/21/2016 12:00:00 AM) | NELIDA | NELIDA | | B= | P | 5226778 |
MASTER BILT HOMES, INC. | B= | P | 06/20/2016 | need safety glass at front stairs / need 1 1/2" from handrail to wall -- Schedule a new Building Final when above items are complete. | DALE | DALE | | B= | P | 5226645 |
MASTER BILT HOMES, INC. | BLA | C | 05/20/2016 | | DALE | DALE | | BLA | C | 5205036 |
MASTER BILT HOMES, INC. | BFR | C | 04/22/2016 | | DALE | DALE | | BFR | C | 5182850 |
MASTER BILT HOMES, INC. | BIN | C | 04/22/2016 | | DALE | DALE | | BIN | C | 5182849 |
MASTER BILT HOMES, INC. | BFR | R | 04/20/2016 | truss laterials missing, recheck all / FHA plate over bored stud at plumbing / strap top plate at basement beam / ok to insulate | DALE | DALE | | BFR | R | 5180932 |
MASTER BILT HOMES, INC. | BSP | T | 04/13/2016 | PAID (REC#1323544) PLAN SPLICE FEE: $50 by: SHELLEY for Construction: revised roof framing at garage | SHELLEY | SHELLEY | | BSP | T | 5175834 |
MASTER BILT HOMES, INC. | BSP | P | 04/05/2016 | front porch frame and posts ok | DALE | DALE | | BSP | P | 5170507 |
MASTER BILT HOMES, INC. | BSP | P | 03/25/2016 | front and rear deck piers ok | DALE | DALE | | BSP | P | 5162768 |
MASTER BILT HOMES, INC. | BFI | C | 02/29/2016 | | DALE | DALE | | BFI | C | 5144166 |
MASTER BILT HOMES, INC. | BFT | C | 02/26/2016 | ok per eng. | DALE | DALE | | BFT | C | 5143388 |
MASTER BILT HOMES, INC. | BFN | C | 02/26/2016 | ok per eng. / all paperwork on file / float | DALE | DALE | | BFN | C | 5143384 |
MASTER BILT HOMES, INC. | BFD | C | 02/26/2016 | | DALE | DALE | | BFD | C | 5143381 |
MASTER BILT HOMES, INC. | BFT | P | 02/12/2016 | AUTHORIZED INSPECTION BY ENGINEER | REBECCA | REBECCA | REBECCA | BFT | P | 5133231 |
MASTER BILT HOMES, INC. | BFN | P | 02/12/2016 | AUTHORIZED INSPECTION BY ENGINEER | REBECCA | REBECCA | REBECCA | BFN | P | 5133230 |
FIRST RATE ELECTRICAL SERVICES, INC. | E= | C | 06/13/2016 | | MATTHEW | MATTHEW | | E= | C | 5221328 |
FIRST RATE ELECTRICAL SERVICES, INC. | EP | C | 06/10/2016 | 80 amp 4/w sub panel in unfinished basement ok | CRAIG | CRAIG | | EP | C | 5220322 |
FIRST RATE ELECTRICAL SERVICES, INC. | E= | R | 06/10/2016 | install arc shield in master bath ------------- install bond screw in well disconnect ----------- hot tub pre wire | CRAIG | CRAIG | | E= | R | 5220317 |
FIRST RATE ELECTRICAL SERVICES, INC. | EUG | C | 04/26/2016 | service lateral ok ------------------------------- bond screw on ground bar in sub-panel is stripped; needs to be fixed by final------------------ | MATTHEW | MATTHEW | | EUG | C | 5185108 |
FIRST RATE ELECTRICAL SERVICES, INC. | ES | C | 04/26/2016 | Residential Underground: 200 amp 3/w: new res--- meter is set; need seal | MATTHEW | MATTHEW | | ES | C | 5185104 |
FIRST RATE ELECTRICAL SERVICES, INC. | ER | C | 04/19/2016 | install flex connectors on flex for well check on final 1 - 15 2 - 10/3 3 - 6/3 al 6/3 cu unfinished basement no cen vac irreversible crimp by man door to garage | CRAIG | CRAIG | | ER | C | 5180214 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | H= | C | 06/13/2016 | Notes-- unfinished basement. No AC. | JEFFL | JEFFL | | H= | C | 5221068 |
MIDWAY PLUMBING LLC | HC | C | 05/04/2016 | RELEASE METER | JEFFL | JEFFL | | HC | C | 5192113 |
MIDWAY PLUMBING LLC | HO | C | 05/04/2016 | Pressure test ok. 40' installed to existing outside gas. | JEFFL | JEFFL | | HO | C | 5192108 |
SPRINGS GAS, INC. | HI | C | 04/15/2016 | 10 LB. test ok. Notes-- 1 1/4'' main.. 1 furnace.. 1 wh.. 1 fp.. 1 range.. 1 bbq | JEFFL | JEFFL | | HI | C | 5178302 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HRR | C | 04/14/2016 | Notes-- unfinished basement. OSA to return.. Duct design.. | JEFFL | JEFFL | | HRR | C | 5177160 |
JOLLY PLUMBING & HEATING INC. | P= | C | 06/02/2016 | | TIM | TIM | | P= | C | 5213253 |
JOLLY PLUMBING & HEATING INC. | P= | P | 06/01/2016 | need proof of potable water install aav basement lav, wrap stacks thru slab | TIM | TIM | | P= | P | 5212511 |
JOLLY PLUMBING & HEATING INC. | PTO+ | C | 04/15/2016 | added sink in garage w/ running trap | TIM | TIM | | PTO+ | C | 5178239 |
JOLLY PLUMBING & HEATING INC. | PTO | C | 04/12/2016 | | TIM | TIM | | PTO | C | 5175167 |
JOLLY PLUMBING & HEATING INC. | PB | C | 03/07/2016 | | TIM | TIM | | PB | C | 5148941 |
JOLLY PLUMBING & HEATING INC. | PWO | C | 03/04/2016 | | TIM | TIM | | PWO | C | 5148445 |