HOMEOWNER | B= | C | 05/08/2017 | | DALE | DALE | | B= | C | 5499873 |
HOMEOWNER | B= | R | 03/27/2017 | need separate permit for retaining wall / need down spot extensions installed / need permanent address on house and at street / handrail must return to wall at stairs. Additional Inspections Required (computer generated): External Agency Inspection HD= by HEALTHDEPT is not Completed yet. | BOBF | BOBF | | B= | R | 5457031 |
HOMEOWNER | BFR | C | 08/17/2016 | | DALE | DALE | | BFR | C | 5271654 |
HOMEOWNER | BIN | C | 08/17/2016 | | DALE | DALE | | BIN | C | 5271647 |
HOMEOWNER | BFR | P | 08/09/2016 | OK to insulate -- Strap top plate left of garage service door and above window in mudroom -- Missing (5) LUS26's at detail for trusses K1 and K2 -- Frame under stair storage at 24"OC under both sets of stairs -- Isolate 2 steel columns on north side of basement -- Engineer letter received for joist repair | DAKOTAB | DAKOTAB | | BFR | P | 5265429 |
HOMEOWNER | BSP | P | 06/17/2016 | front and rear porches with posts okay / garage narrow wall okay / rear deck piers okay / deck frame for both decks okay | BOBF | BOBF | | BSP | P | 5225436 |
HOMEOWNER | BFD | C | 04/01/2016 | | DALE | DALE | | BFD | C | 5168167 |
HOMEOWNER | BFT | C | 04/01/2016 | ok per eng. | DALE | DALE | | BFT | C | 5168162 |
HOMEOWNER | BFI | C | 04/01/2016 | | DALE | DALE | | BFI | C | 5168160 |
HOMEOWNER | BFN | P | 03/15/2016 | need observation letter for footing inspection / wall and rebar okay / eufer okay / foundation design and open hole observation letter received / 1500psf / habitable | BRIANB | BRIANB | | BFN | P | 5155808 |
HOMEOWNER | BFT | P | 03/09/2016 | AUTHORIZED INSPECTION BY ENGINEER | MINDY | MINDY | MINDY | BFT | P | 5150840 |
HOMEOWNER | E= | C | 02/24/2017 | | JOSEPH | JOSEPH | | E= | C | 5424357 |
HOMEOWNER | E= | R | 12/16/2016 | no power to east rec room and west sewing room. plug holes in bell box. label all circuits in panels, install cover main panel. could not verify arc-fault without panel schedule. gfci protect all 120v receptacle in garage add light and gfci to unfinished / vault in basement | BRET | BRET | | E= | R | 5370805 |
HOMEOWNER | ES | C | 09/20/2016 | Residential Underground: 200 amp 3/w new res ok to set meter | TOMC | TOMC | | ES | C | 5298099 |
HOMEOWNER | EUG | C | 08/24/2016 | 2" pvc from pole to house | MATTHEW | MATTHEW | | EUG | C | 5277321 |
HOMEOWNER | ER | C | 08/05/2016 | | BRET | BRET | | ER | C | 5263414 |
HOMEOWNER | ES | R | 08/03/2016 | Residential Underground: not ready | CRAIG | CRAIG | | ES | R | 5261269 |
HOMEOWNER | ER | R | 08/03/2016 | install connect to well flex ------------- add outlets in master bed room one between bathroom door and door to porch and other is in knock out ------------- make up panels --------------- verify bath circuit stays in bath area ---------------- talk to louie about tr / afci / gfi and dedicated circuits for kitchen / bath room outlets and laundry ------------- need access for j boxes above kitchen ---------------- everything is ran in 12/2 through out house ------------- need who ever wired house be here on next inspect to verify all dedicated circuit no mcc 10/2 ac 2 - 10/3 to oven / well 4/w 1/0 al to sub | CRAIG | CRAIG | | ER | R | 5261268 |
HOMEOWNER | H= | C | 12/16/2016 | Finished basement, louvered door to mech, no a/c, no mantel. | MICHAELS | MICHAELS | | H= | C | 5370900 |
HOMEOWNER | HC | C | 08/05/2016 | RELEASE METER | MICHAELS | MICHAELS | | HC | C | 5263219 |
HOMEOWNER | HRR | C | 08/05/2016 | Rough ok. Note: finished basement, no osa, no a/c, direct vent furnace x2, attic insulation to be foam at roof deck. | MICHAELS | MICHAELS | | HRR | C | 5263216 |
HOMEOWNER | HRR | R | 08/04/2016 | No stamped approved plans on site. Trip fee waived. | MICHAELS | MICHAELS | | HRR | R | 5261847 |
HOMEOWNER | HI | C | 07/28/2016 | 10# test ok. 1 1/2" main to 2-furn, 2-w/h, fp, dryer, c-top, range, bbq, 3/4" lower level stub good for 100k. | MICHAELS | MICHAELS | | HI | C | 5256613 |
HOMEOWNER | H16 | C | 07/21/2016 | Consultation with homeowner concerning RBD inspection requirements and procedures. | MICHAELS | MICHAELS | | H16 | C | 5250831 |
HOMEOWNER | P= | C | 12/16/2016 | received proof of potable water | TIM | TIM | | P= | C | 5370522 |
HOMEOWNER | P= | P | 11/04/2016 | need potable water cert | TIM | TIM | | P= | P | 5336464 |
HOMEOWNER | PTO | C | 08/08/2016 | check access to shut off valves for wall faucet at final | TIM | TIM | | PTO | C | 5263824 |
HOMEOWNER | PTO | P | 07/28/2016 | strap and grade to code including vents, horizontal dry vents not allowed below flood level, run 3" to combo at washer, cant find tempering valve | TIM | TIM | | PTO | P | 5256451 |
HOMEOWNER | PWO | C | 07/06/2016 | no hydrants | TIM | TIM | | PWO | C | 5238183 |
HOMEOWNER | PB | C | 04/12/2016 | | TIM | TIM | | PB | C | 5175226 |