ELEVATION HOMES, LLC | B= | C | 09/21/2016 | finished basement | BRIANB | BRIANB | | B= | C | 5299237 |
ELEVATION HOMES, LLC | BFR | C | 09/21/2016 | post inspection completed BSP 25JUL16 | BRIANB | BRIANB | | BFR | C | 5299206 |
ELEVATION HOMES, LLC | BSP | P | 07/25/2016 | posts ok --- engineers letter on file for posts | SCOTTS | SCOTTS | | BSP | P | 5253047 |
ELEVATION HOMES, LLC | BLA | C | 07/07/2016 | | BRIANB | BRIANB | | BLA | C | 5239614 |
ELEVATION HOMES, LLC | BFR | P | 06/24/2016 | still need porch posts, everything else ok | DALE | DALE | | BFR | P | 5231009 |
ELEVATION HOMES, LLC | BFR | R | 06/22/2016 | still missing nails on narrow braced wall and porch posts / eng. on file | DALE | DALE | | BFR | R | 5228609 |
ELEVATION HOMES, LLC | BIN | C | 06/22/2016 | | DALE | DALE | | BIN | C | 5228606 |
ELEVATION HOMES, LLC | BFR | P | 06/16/2016 | missing anchor bolts within 12" both side plate break back left of garage -- narrow wall missing 2nd row nailing per plan on left side 3rd car -- missing blocking on sheathing on narrow wall -- missing 1000 lb straps on narrow wall -- need eng for window moved from side wall to rear wall -- missing posts for deck/porches --- contractor to provide letter for missing THASL29's and LS30's at TR 29,30,31 -- front porch/deck/deck porch lid ok --- ok to insulate | SCOTTS | SCOTTS | | BFR | P | 5224269 |
ELEVATION HOMES, LLC | BSP | P | 04/29/2016 | 4 deck piers ok | DALE | DALE | | BSP | P | 5188015 |
ELEVATION HOMES, LLC | BFI | C | 04/20/2016 | | DALE | DALE | | BFI | C | 5180967 |
ELEVATION HOMES, LLC | BFT | C | 04/20/2016 | ok per eng. | DALE | DALE | | BFT | C | 5180966 |
ELEVATION HOMES, LLC | BFN | C | 04/20/2016 | ok per eng. / float | DALE | DALE | | BFN | C | 5180955 |
ELEVATION HOMES, LLC | BFD | C | 04/20/2016 | drain daylight NW corner | DALE | DALE | | BFD | C | 5180954 |
ELEVATION HOMES, LLC | BFN | P | 03/11/2016 | AUTHORIZED INSPECTION BY ENGINEER | NELIDA | NELIDA | NELIDA | BFN | P | 5153650 |
ELEVATION HOMES, LLC | BFT | P | 03/11/2016 | AUTHORIZED INSPECTION BY ENGINEER | NELIDA | NELIDA | NELIDA | BFT | P | 5153651 |
HOMERUN ELECTRONICS, INC. | E= | C | 09/20/2016 | Generator disconnected. Pre wire only. Generator connection will have to be under a separate permit when ready. | DEAN | DEAN | | E= | C | 5297640 |
HOMERUN ELECTRONICS, INC. | E= | P | 09/19/2016 | need notarized letter from homeowner and rest of covers at generator (breaker exposed to weather) | MATTHEW | MATTHEW | | E= | P | 5296991 |
HOMERUN ELECTRONICS, INC. | ES | C | 09/16/2016 | Residential Underground: 200 amp 3/w: new res----- need meter seal | MATTHEW | MATTHEW | | ES | C | 5295795 |
HOMERUN ELECTRONICS, INC. | E= | R | 09/16/2016 | need grounding electrode conductor landed on neutral bar or main bonding jumper installed at service disconnect, at generator need neutral bonded to ground and ground rod installed, need labels per 705.10 (2 sources of power: utility and generator) at service disconnect, generator and transfer switch need notarized letter from homeowner stating generator will not carry entire load of house, bar lights and bed room receps still not working (both controlled by second switch at wet bar)--------- a/c pre-wire and hot tub pre-wire | MATTHEW | MATTHEW | | E= | R | 5295782 |
HOMERUN ELECTRONICS, INC. | ES | R | 09/12/2016 | where is the generator located ???? | CRAIGS | CRAIGS | | ES | R | 5290297 |
HOMERUN ELECTRONICS, INC. | E= | R | 09/12/2016 | septic wire needs installed in a box and blanked off ---basement bathroom vent fan don't work--bed room #4 receptacles don't work -- can lights above the wet bar don't work ---gfci in the vault won't trip --- lock nut same box not tight --- open all metal boxes in the vault to verify grounds as asked for on the rough inspection ----label upstairs panel correctly , washer , disposal verify all the labels to make sure they are correct ---need a ladder on site to check the eve receptacles ---- two gang weather proof blank for the bell box under the patio , whats this box for ??? ,----- no A/C | CRAIGS | CRAIGS | | E= | R | 5290293 |
HOMERUN ELECTRONICS, INC. | ER | C | 06/15/2016 | metal boxes in vault not grounded; leave open for final | MATTHEW | MATTHEW | | ER | C | 5223440 |
HOMERUN ELECTRONICS, INC. | EUG | C | 06/15/2016 | service lateral from pedestal to home | MATTHEW | MATTHEW | | EUG | C | 5223434 |
HOMERUN ELECTRONICS, INC. | ES | R | 06/15/2016 | need temp removed; recall at final neutral switched at transfer; will need generator installed at time of final (neutral will need to be bonded in generator and ground rods installed) 1/0 al to generator, 4/0al to sub-panel ----------------------200 amp disconnect will need grounding electrode conductor landed on neutral bar or main bonding jumper in stalled--------------------- | MATTHEW | MATTHEW | | ES | R | 5223432 |
HOMERUN ELECTRONICS, INC. | ER | R | 06/13/2016 | wire can in foyer, make up grounds in smokes, wire 3 way in basement bath, need wiring installed from well controller stubbed outside, ground metal boxes in vault, transfer switch not rated as service disconnect, need to service disconnect----------------- finished basement, 2/0 al sub-panel, no mcc's, 6-3nm to cooking, 2/0 from exterior j-box to transfer switch, no vac, non-ir ufer | MATTHEW | MATTHEW | | ER | R | 5221411 |
THE FURNACE GUY HEATING & COOLING | H= | C | 09/01/2016 | Notes-- AC rough coil and line set. Louver door to mech room. | JEFFL | JEFFL | | H= | C | 5283673 |
THE FURNACE GUY HEATING & COOLING | HC | C | 06/15/2016 | RELEASE METER | JEFFL | JEFFL | | HC | C | 5223164 |
THE FURNACE GUY HEATING & COOLING | HRR | C | 06/15/2016 | Notes-- finished basement. Duct design. OSA to return. AC rough coil and line set. | JEFFL | JEFFL | | HRR | C | 5223163 |
SPRINGS GAS, INC. | HI | C | 06/01/2016 | 10# test ok. Notes-- 1 1/4'' main.. 1 furnace.. 1 wh.. 2 fp.. 1 range.. | JEFFL | JEFFL | | HI | C | 5212519 |
PACIFIC PLUMBING, INCORPORATED | P= | C | 09/14/2016 | received potable water cert | TIM | TIM | | P= | C | 5292502 |
PACIFIC PLUMBING, INCORPORATED | P= | R | 09/08/2016 | still need proof of potable water | TIM | TIM | | P= | R | 5288043 |
PACIFIC PLUMBING, INCORPORATED | P= | R | 09/07/2016 | should be trip fee no wtr also need proof of potable water re-inspect all | TIM | TIM | | P= | R | 5286904 |
HOMEOWNER | PWO | P | 08/04/2016 | need tie in at well...ck sleeve in foundation at final no hydrants | TIM | TIM | | PWO | P | 5261902 |
PACIFIC PLUMBING, INCORPORATED | PTO | C | 06/03/2016 | aav in basement and sink in room next to garage | TIM | TIM | | PTO | C | 5214735 |
PACIFIC PLUMBING, INCORPORATED | PB | C | 04/27/2016 | | TIM | TIM | | PB | C | 5186210 |