FRED FLETEMEYER COMPANY GENERAL CONTRACTORS, INC. | B= | C | 02/14/2017 | All other required Final inspections are complete. (This is a computer generated result) | DANE | DANE | | B= | C | 5414442 |
FRED FLETEMEYER COMPANY GENERAL CONTRACTORS, INC. | B= | P | 01/20/2017 | items corrected / final OK pending outside agencies. Additional Inspections Required (computer generated): External Agency Inspection Z= by ZONING is not Completed yet (Contact: 719-385-5982). | DANE | DANE | | B= | P | 5394024 |
FRED FLETEMEYER COMPANY GENERAL CONTRACTORS, INC. | B= | P | 01/20/2017 | image of dead bolt removed and hole blanked on file / items corrected / final OK pending outside agency finals. Additional Inspections Required (computer generated): External Agency Inspection Z= by ZONING is not Completed yet (Contact: 719-385-5982). | DANE | DANE | | B= | P | 5393688 |
FRED FLETEMEYER COMPANY GENERAL CONTRACTORS, INC. | B= | P | 01/17/2017 | need to remove dead bolt lock at sprinkler room -- Schedule a new Building Final when above items are complete. Additional Inspections Required (computer generated): External Agency Inspection Z= by ZONING is not Completed yet (Contact: 719-385-5982). | DANE | DANE | | B= | P | 5390593 |
FRED FLETEMEYER COMPANY GENERAL CONTRACTORS, INC. | BSP | P | 01/17/2017 | assembly for use of American Gyp at fire wall on file / wall assembly OK | DANE | DANE | | BSP | P | 5389602 |
FRED FLETEMEYER COMPANY GENERAL CONTRACTORS, INC. | BSP | P | 01/17/2017 | exterior wall detail judgment on file | DANE | DANE | | BSP | P | 5389523 |
FRED FLETEMEYER COMPANY GENERAL CONTRACTORS, INC. | BSP | P | 01/17/2017 | exterior wall judgment and head of wall mineral wool letter on file | DANE | DANE | | BSP | P | 5389518 |
FRED FLETEMEYER COMPANY GENERAL CONTRACTORS, INC. | BFN | C | 12/23/2016 | open hole on file | DANE | DANE | | BFN | C | 5375646 |
FRED FLETEMEYER COMPANY GENERAL CONTRACTORS, INC. | BFR | P | 10/19/2016 | discussed with super the need for the open hole report and the new listing for the fire wall that used American gyp | DANE | DANE | | BFR | P | 5322713 |
FRED FLETEMEYER COMPANY GENERAL CONTRACTORS, INC. | BIN | C | 10/19/2016 | core shell insulation OK | DANE | DANE | | BIN | C | 5322694 |
FRED FLETEMEYER COMPANY GENERAL CONTRACTORS, INC. | BLA | C | 10/19/2016 | sheet rock installed OK / lath OK | DANE | DANE | | BLA | C | 5322634 |
FRED FLETEMEYER COMPANY GENERAL CONTRACTORS, INC. | BIN | P | 08/17/2016 | insulation in riser room exterior wall OK | DANE | DANE | | BIN | P | 5271942 |
FRED FLETEMEYER COMPANY GENERAL CONTRACTORS, INC. | BFN | P | 08/01/2016 | engineer observation report on file / still need stamped copy of open hole | DANE | DANE | | BFN | P | 5258114 |
FRED FLETEMEYER COMPANY GENERAL CONTRACTORS, INC. | BLA | R | 07/25/2016 | stucco lath at north inside corner to southwest corner OK but wall at southwest corner running east is to be a UL U419 and it is to have sheetrock brand firecode core gypsum or firerock brand aqua-tough exterior sheating per print and it is covered with OSB under the stucco lath | DANE | DANE | | BLA | R | 5253127 |
FRED FLETEMEYER COMPANY GENERAL CONTRACTORS, INC. | BSP | P | 07/22/2016 | West wing wall at exterior (UL 419): Exterior drywall OK | JEREMYA | JEREMYA | | BSP | P | 5251645 |
FRED FLETEMEYER COMPANY GENERAL CONTRACTORS, INC. | BLA | R | 07/15/2016 | north wall at east side of building is to be a UL U419 1 hour rated wall and is not built per the U419 listing / please provide a new listing or build per U419 / rest of stucco lath on east side OK | DANE | DANE | | BLA | R | 5246119 |
FRED FLETEMEYER COMPANY GENERAL CONTRACTORS, INC. | BFR | P | 07/07/2016 | front and rear light gauge wall framing OK pending other roughs / all box headers and stud packs have been pre-insulated / north 2hr rated wall is called as a U412 and has not been built per listing - need new listing for shaft liner that has been used / still need all foundation observations and open hole | DANE | DANE | | BFR | P | 5239860 |
FRED FLETEMEYER COMPANY GENERAL CONTRACTORS, INC. | BFT | P | 07/07/2016 | OK to use engineer | DANE | DANE | | BFT | P | 5239859 |
FRED FLETEMEYER COMPANY GENERAL CONTRACTORS, INC. | BFN | P | 07/07/2016 | OK to use engineer | DANE | DANE | | BFN | P | 5239855 |
SAWYER ELECTRIC, INC | E= | C | 10/26/2016 | | BRET | BRET | | E= | C | 5328463 |
SAWYER ELECTRIC, INC | ER | P | 09/28/2016 | exterior walls east and west | BRET | BRET | | ER | P | 5304997 |
SAWYER ELECTRIC, INC | ES | C | 08/17/2016 | Commercial Service: 100 amp 4/w to main home panel ok to set meter for house panel only | CRAIG | CRAIG | | ES | C | 5271586 |
SAWYER ELECTRIC, INC | ER | P | 08/16/2016 | walls for mech rm only for core / shell | CRAIG | CRAIG | | ER | P | 5270101 |
COLORADO SHEET METAL CO., INC. | H= | C | 12/28/2016 | CORRECTIONS MADE PER NOTES FROM PREVIOUS INSPECTOR.. | LUKE | LUKE | | H= | C | 5377514 |
O.M.A.G.M., INC. | H= | C | 11/04/2016 | GAS FINAL OK. | NANCY | NANCY | | H= | C | 5336897 |
O.M.A.G.M., INC. | H= | P | 11/01/2016 | GAS FINAL OK PENDING CONTRACTOR CALLING IN INSPECTION. | NANCY | NANCY | | H= | P | 5333697 |
COLORADO SHEET METAL CO., INC. | H= | P | 11/01/2016 | MECHANICAL FINAL OK PENDING PERMANENT LADDER BEING INSTALLED ON BUILDING. | NANCY | NANCY | | H= | P | 5333696 |
O.M.A.G.M., INC. | HC | C | 09/19/2016 | OK FOR METER RELEASE | JERRYF | JERRYF | | HC | C | 5296063 |
O.M.A.G.M., INC. | HI | C | 09/16/2016 | PRESSURE TEST OK - PIPING PER PLAN AND REG IS COMPLETE - BEFORE METER RELEASE NEED SUITE NUMBER POSTED AT FRONT OF UNIT - BY FINAL NEED ALL LABELS INSTALLED NOTES 2# LETTER IN SYSTEM | JERRYF | JERRYF | | HI | C | 5294886 |
HOGAN MECHANICAL, INC. | P= | C | 12/23/2016 | | JOEL | JOEL | | P= | C | 5375764 |
HOGAN MECHANICAL, INC. | PB | C | 09/21/2016 | GREASE WASTE , TO PLAN ON TEST , CORRECTIONS MADE | GABE | GABE | | PB | C | 5298605 |
HOGAN MECHANICAL, INC. | PB | P | 09/20/2016 | LEAK AT COUPLING NORTH OF END OF LINE CO , LEAK AT 90 AT END OF LINE CO, REST OK , RE TEST AFTER CORRECTIONS MADE | GABE | GABE | | PB | P | 5297751 |
HOGAN MECHANICAL, INC. | PTO | C | 08/31/2016 | NOTE : WATER IN, METER IN , ALL TO PLAN , CORE/SHELL ONLY | GABE | GABE | | PTO | C | 5282452 |
HOGAN MECHANICAL, INC. | PB | P | 08/05/2016 | NEED TO HAVE PLANS SPLICED TO SHOW SANITARY FROM NEXT UNIT OVER TIE IN , CORE/SHELL ONLY , SANITARY DWV ON TEST , ALL TO PLAN | GABE | GABE | | PB | P | 5263085 |