CLANCY BUILDING & DESIGN, LLC | B= | C | 04/18/2017 | corrections made | LINDSEY | LINDSEY | | B= | C | 5478483 |
CLANCY BUILDING & DESIGN, LLC | B= | R | 04/14/2017 | Call ahead complete at 9:06 // no access at 9:37 | LINDSEY | LINDSEY | | B= | R | 5475041 |
CLANCY BUILDING & DESIGN, LLC | B= | P | 01/24/2017 | need to post address on house per RBC code / need to insulate mechanical room walls / need ladder to inspect attic insulation / need stair treads on rear deck / need egress ladder for west bedrooms / complete other final inspections -- Schedule a new Building Final when above items are complete. Additional Inspections Required (computer generated): External Agency Inspection F= by FIREDEPT is not Completed yet (Contact: 385-5982, x2), External Agency Inspection N= by ENGINEERING is not Completed yet (Contact: City Engineering Inspections 719-385-5977). | ERICR | ERICR | | B= | P | 5397633 |
CLANCY BUILDING & DESIGN, LLC | BLA | C | 09/08/2016 | | ERICR | ERICR | | BLA | C | 5288056 |
CLANCY BUILDING & DESIGN, LLC | BIN | C | 09/06/2016 | correction completed | ERICR | ERICR | | BIN | C | 5285539 |
CLANCY BUILDING & DESIGN, LLC | BFR | C | 09/02/2016 | corrections completed | ERICR | ERICR | | BFR | C | 5285075 |
CLANCY BUILDING & DESIGN, LLC | BIN | P | 09/02/2016 | they missed blowing in the rim under front entry in basement | ERICR | ERICR | | BIN | P | 5285070 |
CLANCY BUILDING & DESIGN, LLC | BFD | C | 08/30/2016 | received drain design / received rear deck bearing fix for bearing of front beam | ERICR | ERICR | | BFD | C | 5281403 |
CLANCY BUILDING & DESIGN, LLC | BFN | C | 08/30/2016 | Received foundation design / Engineers observation Letter on file / Eufer OK / Soils report on file / | ERICR | ERICR | | BFN | C | 5281391 |
CLANCY BUILDING & DESIGN, LLC | BFT | C | 08/30/2016 | Engineers observation Letter on file / Soils report on file / | ERICR | ERICR | | BFT | C | 5281390 |
CLANCY BUILDING & DESIGN, LLC | BSP | P | 08/30/2016 | missing trim and each side of window south east bedroom window / missing bolting of 3 ply girder truss missing two hts 20 straps at 3 ply girder over bearing points middle of house/ missing bearing column for 3 ply girder truss T02G should be 8 ply column / missing trimmers on south basement windows and king stud on either of little windows / need new south elevation showing window changes | ERICR | ERICR | | BSP | P | 5281381 |
CLANCY BUILDING & DESIGN, LLC | BSP | P | 08/17/2016 | portal frame blocking ok / need engineering for bearing point of rear deck beam and post. Beam does not bear on post | ERICR | ERICR | | BSP | P | 5271308 |
CLANCY BUILDING & DESIGN, LLC | BSP | P | 08/10/2016 | need to add blocking at plywood splices and nail off per detail | ERICR | ERICR | | BSP | P | 5266049 |
CLANCY BUILDING & DESIGN, LLC | BFN | P | 08/10/2016 | Received foundation observation letter / need open hole observation , soils report, and foundation design | ERICR | ERICR | | BFN | P | 5265628 |
CLANCY BUILDING & DESIGN, LLC | BFT | P | 08/10/2016 | Received observation letter on footer/ need open hole observation, soils report and foundation design | ERICR | ERICR | | BFT | P | 5265626 |
CLANCY BUILDING & DESIGN, LLC | BFD | P | 08/10/2016 | received foundation Drain observation / need drain design | ERICR | ERICR | | BFD | P | 5265623 |
CLANCY BUILDING & DESIGN, LLC | BSP | P | 08/09/2016 | front and rear porch piers ok/ many broken trusses to many to list / porch roofs ok / need to check post connections / truss hardware ok/ truss bracing ok | ERICR | ERICR | | BSP | P | 5264965 |
CLANCY BUILDING & DESIGN, LLC | BFD | P | 05/06/2016 | AUTHORIZED INSPECTION BY ENGINEER | REBECCA | REBECCA | REBECCA | BFD | P | 5193310 |
CLANCY BUILDING & DESIGN, LLC | BFT | P | 05/06/2016 | AUTHORIZED INSPECTION BY ENGINEER | REBECCA | REBECCA | REBECCA | BFT | P | 5193309 |
CLANCY BUILDING & DESIGN, LLC | BFN | P | 05/06/2016 | AUTHORIZED INSPECTION BY ENGINEER | REBECCA | REBECCA | REBECCA | BFN | P | 5193308 |
SANCHEZ ELECTRIC, INC. | E= | C | 01/19/2017 | | JOHNN | JOHNN | | E= | C | 5392572 |
SANCHEZ ELECTRIC, INC. | E= | R | 01/18/2017 | basement sub panel is missing 2 cover screws,down stairs bath rm light reads open grd,----------------------------notes:30 amp a/c pre wire | JOHNN | JOHNN | | E= | R | 5391505 |
SANCHEZ ELECTRIC, INC. | E= | R | 01/13/2017 | HOT CHECK ENTIRE HOUSE,gfci garage won't reset,outside outlets off kitchen,not wired correctly,need cb locks on oven,microwave,need inter system bond terminal,complete re inspect | JOHNN | JOHNN | | E= | R | 5388499 |
SANCHEZ ELECTRIC, INC. | ES | C | 09/02/2016 | Residential Underground: 200 amp service new res. | BRET | BRET | | ES | C | 5284818 |
SANCHEZ ELECTRIC, INC. | ER | C | 08/29/2016 | L.V CENT. VAC | MIKEC | MIKEC | | ER | C | 5280684 |
SANCHEZ ELECTRIC, INC. | ES | R | 08/29/2016 | NOT READY | MIKEC | MIKEC | | ES | R | 5280673 |
AIR CONCEPTS HEATING & COOLING | H= | C | 01/19/2017 | CORRECTIONS MADE | DAVIDH | DAVIDH | | H= | C | 5393107 |
AIR CONCEPTS HEATING & COOLING | H= | P | 01/17/2017 | MECH RM LACKS COMBUSTION AIR NOTE DIRECT VENT FURN | DAVIDH | DAVIDH | | H= | P | 5390281 |
AIR CONCEPTS HEATING & COOLING | HC | C | 08/31/2016 | RELEASE METER | PAULO | PAULO | | HC | C | 5282382 |
AIR CONCEPTS HEATING & COOLING | HRR | C | 08/31/2016 | EQUIPMENT CERTIFICATION IS OK. RECEIVED 600 CFM DOWNDRAFT JENN-AIR COOK TOP PAPERWORK AND SCANNED, INSTALLED PER CONTRACTOR. NOTE: FINISHED BASEMENT, DIRECT VENT FURNACE, 6" OUTSIDE AIR TO RETURN, NO A/C, DUCT DESIGN. | PAULO | PAULO | | HRR | C | 5282380 |
AIR CONCEPTS HEATING & COOLING | HRR | P | 08/29/2016 | PLANS DO NOT SHOW A KITCHEN EXHAUST NOR DOES IT SHOW THE MAX CFM (JENN-AIR), MISSING SUPPLY AIR RUN AT MASTER BED ROOM CLOSET. NO EQUIPMENT CERT. AT JOB SITE. 08-30-16: DRAFT HOOD APPLIANCE OSA DAMPER ARE NOT REQUIRED.
NOTE: DUCT DESIGN, DIRECT VENT FURNACE-80K, NO A/C ROUGH, 6 INCH OUT SIDE AIR TO RETURN, | CHUCKF | CHUCKF | | HRR | P | 5280455 |
AIR CONCEPTS HEATING & COOLING | HI | C | 08/29/2016 | 10# TEST OK, 1 1/4 INCH BLACK MAIN, 2 EA.-WATER HEATER, 2 EA.- FIRE PLACES, DIRECT VENT FURNACE- 80K, RANGE. | CHUCKF | CHUCKF | | HI | C | 5280448 |
CHEYENNE PLUMBING & HEATING, INC. | P= | C | 01/12/2017 | RP installed, finished basement. | TAYLOR | TAYLOR | | P= | C | 5387691 |
CHEYENNE PLUMBING & HEATING, INC. | PTO | C | 08/19/2016 | finished basement | JOEL | JOEL | | PTO | C | 5273487 |
CHEYENNE PLUMBING & HEATING, INC. | PTO | R | 08/16/2016 | no stairs, re- inspect all. | TAYLOR | TAYLOR | | PTO | R | 5270015 |
CHEYENNE PLUMBING & HEATING, INC. | PB | C | 05/20/2016 | ok | DICK | DICK | | PB | C | 5204562 |