PEAK SIDE PROPERTIES, LLC | B= | C | 01/19/2018 | corrections complete | SCOTTS | SCOTTS | | B= | C | 5743280 |
PEAK SIDE PROPERTIES, LLC | B= | R | 01/12/2018 | Shingles blown off less than a square over garage // down spouts not connected front of home// finished basement // deck // no AC | NOAH | NOAH | | B= | R | 5737484 |
PEAK SIDE PROPERTIES, LLC | BIN | C | 12/15/2017 | | JEREMYA | JEREMYA | | BIN | C | 5713613 |
PEAK SIDE PROPERTIES, LLC | BFR | C | 12/15/2017 | Engineer letter to complete framing on file | JEREMYA | JEREMYA | | BFR | C | 5713611 |
PEAK SIDE PROPERTIES, LLC | B= | P | 12/14/2017 | Temp CO: All finalas are partialed ( Expires: 1/13/2018 12:00:00 AM) | GITA | GITA | | B= | P | 5713093 |
PEAK SIDE PROPERTIES, LLC | B= | P | 12/13/2017 | still need to complete frame, insulation and pluming final inspections / still need to complete custom guard and rail at basement stairs / still have over 3/8" difference in rise at basement stairs / other corrections okay / walked inspection with Peak Side rep Andy / note - changed inspection from BT = to partial building final inspection per Inspector JA -- Schedule a new Building Final when above items are complete. | BRIANB | BRIANB | | B= | P | 5712143 |
PEAK SIDE PROPERTIES, LLC | BT= | R | 12/12/2017 | Met on-site with contractor. Missing guard rail and handrail at basement stairs. Missing handrail at garage stairs. Stair rise exceeds 3/8" variance between rises at basement stairs. Contractor is waiting on the guards to be completed. Will install code compliant guard to remain in place until the fabrication is complete | JEREMYA | JEREMYA | | BT= | R | 5710390 |
PEAK SIDE PROPERTIES, LLC | BSP | P | 08/30/2017 | deck post connections okay | LUKES | LUKES | | BSP | P | 5611791 |
PEAK SIDE PROPERTIES, LLC | BSP | R | 07/17/2017 | lath not present around front door | SCOTTS | SCOTTS | | BSP | R | 5567082 |
PEAK SIDE PROPERTIES, LLC | BLA | C | 06/14/2017 | Call for BSP inspection on lath around 2 entry doors on north side after doors are installed // Rest of lath okay // Okay to start brown coat | SHAUN | SHAUN | | BLA | C | 5535402 |
PEAK SIDE PROPERTIES, LLC | BIN | R | 02/22/2017 | complete BFR -- insulation ok | SCOTTS | SCOTTS | | BIN | R | 5422291 |
PEAK SIDE PROPERTIES, LLC | BFR | R | 02/22/2017 | still need letter addressing foundation cut out and top reinforcing cut out on inspection from 11/10/2016 -- other corrections complete | SCOTTS | SCOTTS | | BFR | R | 5422290 |
PEAK SIDE PROPERTIES, LLC | BSP | R | 02/22/2017 | missing post in front and posts at deck/rear porch cover posts ok | SCOTTS | SCOTTS | | BSP | R | 5422289 |
PEAK SIDE PROPERTIES, LLC | BIN | P | 02/16/2017 | Insulation OK // Partial pending remanent installation of door or windows at NW corner of house | JEREMYA | JEREMYA | | BIN | P | 5417034 |
PEAK SIDE PROPERTIES, LLC | BFR | P | 01/17/2017 | Still need to fire block ENDS of garage door brackets. Need 1.5" of backing all the way around the metal bracket for drywall attachment // Still have temporary cover at door next to front door // OK to insulate | JEREMYA | JEREMYA | | BFR | P | 5390677 |
PEAK SIDE PROPERTIES, LLC | BFR | T | 01/13/2017 | PAID (REC#1395378): per previous inspection - THAJ not installed, door in basement not installed / wind bracing at gables not done / ends of garage door brackets not blocked | BOBF | BOBF | | BFR | T | 5389181 |
PEAK SIDE PROPERTIES, LLC | BFR | P | 01/13/2017 | BCI Joist letter on file // Letter for beam support change from beam pockets to posts on file | JEREMYA | JEREMYA | | BFR | P | 5388319 |
PEAK SIDE PROPERTIES, LLC | BFR | R | 01/09/2017 | missing door at basement // missing THJA at CG61 // missing window at north west corner// isokate t-posts in basement // fireblock wnds of garage door brackets // per comparison, TJI 230 and BCI 6000 1.8 are not equivalent . will need enguneer kwttwr statinf BCI 6000 1.8 are ok in lieu of TJI 230 or BCI 6500 1.8 // plans indicate foundation walls where there is framing. will need letter and details for wood framing // wind brace gables 4' o.c. // need to have approved plans on site // training with Ruch B. | JEREMYA | JEREMYA | | BFR | R | 5384760 |
PEAK SIDE PROPERTIES, LLC | BSP | T | 11/10/2016 | PAID (REC#1381221) PLAN SPLICE FEE: $50 by: MICHAELA for Construction: Enlarge deck | MICHAELA | MICHAELA | | BSP | T | 5342280 |
PEAK SIDE PROPERTIES, LLC | BSP | R | 11/10/2016 | pending splice for deck -- rear porch lid needs H2.5's on trusses -- deck framing ok/deck piers ok -- need engineer letter for foundation cut at rear lower slider door | SCOTTS | SCOTTS | | BSP | R | 5342198 |
PEAK SIDE PROPERTIES, LLC | BSP | R | 11/04/2016 | no plans on site -- need to roll block truss heels 8" and over/missing H2.5's -- rear deck extended/need to update plot plan and splice plans for additional framing/piers -- front pier ok | SCOTTS | SCOTTS | | BSP | R | 5337296 |
PEAK SIDE PROPERTIES, LLC | BFD | C | 06/09/2016 | Drain usable / Damp proofing OK | JEREMYA | JEREMYA | | BFD | C | 5219169 |
PEAK SIDE PROPERTIES, LLC | BFI | C | 06/09/2016 | Rigid foam insulation installed | JEREMYA | JEREMYA | | BFI | C | 5219166 |
PEAK SIDE PROPERTIES, LLC | BFN | C | 06/09/2016 | Engineers observation Letter on file / Eufer OK / Foundation design on file / Soils report on file | JEREMYA | JEREMYA | | BFN | C | 5219165 |
PEAK SIDE PROPERTIES, LLC | BFT | C | 06/09/2016 | Engineers observation Letter on file / Soils report on file | JEREMYA | JEREMYA | | BFT | C | 5219163 |
PEAK SIDE PROPERTIES, LLC | BFT | P | 06/01/2016 | AUTHORIZED INSPECTION BY ENGINEER | JANE | JANE | JANE | BFT | P | 5211810 |
PEAK SIDE PROPERTIES, LLC | BFN | P | 06/01/2016 | AUTHORIZED INSPECTION BY ENGINEER | JANE | JANE | JANE | BFN | P | 5211809 |
MEYER ELECTRIC | E= | C | 12/08/2017 | corrections made | RANDY | RANDY | | E= | C | 5707478 |
MEYER ELECTRIC | E= | R | 12/07/2017 | 1) id panels correctly 2) need w/p recept back deck-main level, 3) floor recept's 1/2 working only 4) tie handles on cooking units, 5) a/c's #1-30 amps, #2 20 amps, id accordingly | GARYL | GARYL | | E= | R | 5706452 |
SPRINGS FAMILY ELECTRIC | ES | C | 10/26/2017 | 2-200 amp 3 wire service for new residence ok to energize per Randy. -------------------originally sent to CSU------------------------ | DEAN | DEAN | | ES | C | 5668047 |
SPRINGS FAMILY ELECTRIC | ES | C | 10/24/2017 | Residential Underground: 2-200 amp 3/w new new res--ok to set meter | RANDY | RANDY | | ES | C | 5665447 |
SPRINGS FAMILY ELECTRIC | ES | R | 10/20/2017 | Not ready. Service lateral not long enough. Contractor will splice lateral and leave paper work on splice. -------- Total re-inspect | JOSEPH | JOSEPH | | ES | R | 5662525 |
SPRINGS FAMILY ELECTRIC | EUG | C | 10/19/2017 | 2- 4/0 4/0 2/0 laterals from meter to panels at garage---stubbed up only-no pipe / | ROB | ROB | | EUG | C | 5661369 |
SPRINGS FAMILY ELECTRIC | ER | C | 11/18/2016 | | TOMC | TOMC | | ER | C | 5348924 |
SPRINGS FAMILY ELECTRIC | ER | R | 11/15/2016 | add receptacle by stairs in foyer , add receptacle by lower walk-out , need access to ufer , seal wires in return lower level North West bedroom , lower level laundry ------- 2 - 200 amp MB panels , 1 - 200 amp ML sub-panel , 6 - #6 AL , 4 - #10 , no mcc , no central vac , full finish | TOMC | TOMC | | ER | R | 5345518 |
ADVANTAGE HEATING AND COOLING | H= | C | 12/06/2017 | CORRECTIONS MADE. | LIDO | LIDO | | H= | C | 5705647 |
ADVANTAGE HEATING AND COOLING | H= | P | 12/05/2017 | need the following-- combustion air to mechanical room, complete gas flex to water heater, correct vent termination to water heater per manufactures installations, proper R.A. path to 1- basement bedroom. rest ok. note: finished basement, 6" outside air to each furnace return, 2- direct vent furnaces with zoned systems, indirect vent water heater, 2- a/c's complete, 2- mini splits complete, no mantels. | PAULO | PAULO | | H= | P | 5702954 |
HENDERSON PROPANE SERVICE INC. | HO | C | 12/01/2017 | Burial depth ok. | JEFFL | JEFFL | | HO | C | 5700450 |
HENDERSON PROPANE SERVICE INC. | HO | P | 11/30/2017 | TRENCH DEPTH NEEDS TO BE MINIMUM 18" | LIDO | LIDO | | HO | P | 5699032 |
HENDERSON PROPANE SERVICE INC. | HO | P | 11/16/2017 | RECALL INSPECTION WHEN GRADE IS SET . MET WITH GC AND WAS INFORMED GRADE WILL BE DROPPING THIS WILL IMPACT THE DEPTH OF THE LP GAS LINE . | LIDO | LIDO | | HO | P | 5688050 |
ADVANTAGE HEATING AND COOLING | H16 | C | 01/05/2017 | ADVANTAGE HEATING WILL NEED TO CALL FOR THE HEAT FINAL ON THE HOUSE. NOT FIREPLACE.. | LUKE | LUKE | | H16 | C | 5383400 |
THE FIREPLACE DOCTOR, INC. | HV | C | 01/05/2017 | FIREPLACE AND VENT OK | LUKE | LUKE | | HV | C | 5383397 |
ADVANTAGE HEATING AND COOLING | HI | C | 01/05/2017 | 10 LB GAS TEST GOOD TWO FIREPLACES. | LUKE | LUKE | | HI | C | 5383382 |
ADVANTAGE HEATING AND COOLING | HI | P | 12/27/2016 | GAS FIREPLACES ARE BEING INSTALLED THEY WERE NOT IN PLACE ON HRR INSPECTION WILL NEED A FOLLOW UP HRR + WHEN THEY ARE INSTALLED.. NOTE: 10 LB GAS TEST 1 1/2'' MAIN TWO FIREPLACES BBQ TWO FURNACES RANGE WATER HEATER.. | LUKE | LUKE | | HI | P | 5377089 |
ADVANTAGE HEATING AND COOLING | HRR | C | 11/15/2016 | CALL ME AT 719-799-2872 THIS IS LUKE. CORRECTIONS MADE. | LUKE | LUKE | | HRR | C | 5344944 |
ADVANTAGE HEATING AND COOLING | HRR | T | 11/14/2016 | PAID (REC#1382118): ALL VENTING IN MECHANICAL ROOM FOR TWO DIRECT VENT FURNACES ARE SLOPPED THE WRONG WAY, STILL MISSING NAIL PROTECTION FOR DRYER DUCT. SEAL ALL RETURN PANNING IN MECHANICAL ROOM HEADERS. | LUKE | LUKE | | HRR | T | 5344016 |
ADVANTAGE HEATING AND COOLING | HRR | P | 10/25/2016 | Return bay needs sealed in mech room. Nail plate required at dryer vent. Vent required to be insulated in unconditioned space according to manufacturers specs. ***Cellular core vent pipe not permitted with most water heater manufacturers. No water heater on site to verify.*** | JEFFL | JEFFL | | HRR | P | 5327740 |
ADVANTAGE HEATING AND COOLING | HRR | R | 10/24/2016 | No mechanical plans within plans in mech room. **Noticed foam core vent installed for water heater. Verify water heater vent manufacturer specs**. | JEFFL | JEFFL | | HRR | R | 5326167 |
ADVANTAGE HEATING AND COOLING | HRR | R | 10/20/2016 | Still unable to find mechanical plans on site. Please verify plans are in garage or mech room before re inspection. | JEFFL | JEFFL | | HRR | R | 5324076 |
ADVANTAGE HEATING AND COOLING | HRR | R | 10/18/2016 | No mechanical plans or equipment cert on site. No address posted. | LIDO | LIDO | | HRR | R | 5321708 |
LANDMARK PLUMBING AND HEATING, INC. | P= | C | 12/15/2017 | correction made, see images | TED | TED | | P= | C | 5713526 |
LANDMARK PLUMBING AND HEATING, INC. | P= | R | 12/14/2017 | no access, house locked | TED | TED | | P= | R | 5712758 |
LANDMARK PLUMBING AND HEATING, INC. | P= | P | 12/13/2017 | need high loop on basement dishwasher drain, need certificate of potable water, rest ok, finished basement | TED | TED | | P= | P | 5711361 |
LANDMARK PLUMBING AND HEATING, INC. | P= | P | 12/11/2017 | No hot water, re-inspect all | SHANEN | SHANEN | | P= | P | 5709488 |
HOMEOWNER | PWO | C | 12/22/2016 | | TIM | TIM | | PWO | C | 5374960 |
GOLD RUSH PLUMBING | PTO | C | 10/24/2016 | finished basement, aav bar sink, washer box in basement, double basement lav aav in mech. room, aav north east 1st floor lav | TED | TED | | PTO | C | 5326251 |
GOLD RUSH PLUMBING | PTO | T | 10/20/2016 | PAID (REC#1374442): not ready, still working on it, no test | TED | TED | | PTO | T | 5323846 |
GOLD RUSH PLUMBING | PTO | P | 10/19/2016 | dwv only tests ok, nail protect and anchor flanges | DICK | DICK | | PTO | P | 5322970 |
GOLD RUSH PLUMBING | PB | C | 07/20/2016 | post address at road, note: water main stub under footer, | TED | TED | | PB | C | 5250092 |