MILE HIGH PRIDE REMODELING LLC. | B= | C | 08/09/2016 | insignia#30829 | ERICR | ERICR | | B= | C | 5264663 |
MILE HIGH PRIDE REMODELING LLC. | B= | P | 08/05/2016 | need to install all skirting to complete final -- Schedule a new Building Final when above items are complete. | ERICR | ERICR | | B= | P | 5262779 |
MILE HIGH PRIDE REMODELING LLC. | BTD | C | 07/29/2016 | Clayton homes install manual page 31 ok for single stack piers on perimeter walls up to 54" | BERTW | BERTW | | BTD | C | 5257328 |
MILE HIGH PRIDE REMODELING LLC. | BTD | R | 07/26/2016 | missing screws in tie downs / perimeter piers are over 36" and single stacked/ piers over 36" need to be double stacked | ERICR | ERICR | | BTD | R | 5253786 |
POSITIVELY ELECTRIC, INC. | E= | C | 08/04/2016 | | JOHNN | JOHNN | | E= | C | 5261427 |
POSITIVELY ELECTRIC, INC. | E= | R | 08/03/2016 | need proper sized pipe strap for pvc between meter and house,ground rod clamp only listed for one conductor,need 2nd clamp and rework.need licensed electrical contractor to complete work and attach to permit | JOHNN | JOHNN | | E= | R | 5260382 |
MILE HIGH PRIDE REMODELING LLC. | E= | R | 07/29/2016 | strap pvc per nec between pedestal and home. only one conductor listed for ground rod clamp add second and rework. | BRET | BRET | | E= | R | 5257149 |
MILE HIGH PRIDE REMODELING LLC. | ES | C | 07/29/2016 | Mobile Home Meter Set: 100 amp service needs meter set meter on site. | BRET | BRET | | ES | C | 5257134 |
MILE HIGH PRIDE REMODELING LLC. | ES | R | 07/26/2016 | locked, strap per nec. use approved strapping means for pvc to home, scrap paint under lug, unable to access interior panel, complete re-inspect. | BRET | BRET | | ES | R | 5253686 |
MIKE ROWLAND PLUMBING LLC | HC | C | 08/03/2016 | RELEASE METER | JEFFB | JEFFB | | HC | C | 5260694 |
MIKE ROWLAND PLUMBING LLC | HO= | C | 08/03/2016 | THE INSIDE GAS LINE TEST AT 10 LBS IS GOOD. 1" MAIN. THE OUTSIDE GAS LINE TEST IS ALSO GOOD AT 10 LBS. 1" LINE. THE EXHAUST FANS AND DUCTING. DRYER VENT AND FURNACE ARE ALL GOOD. THERE ARE 2 - CO DETECTORS IN PLACE. THERE IS NO A/C. | JEFFB | JEFFB | | HO= | C | 5260692 |
MILE HIGH PRIDE REMODELING LLC. | PO= | C | 07/29/2016 | correction made | DICK | DICK | | PO= | C | 5257322 |
MILE HIGH PRIDE REMODELING LLC. | PO= | P | 07/26/2016 | can not use sanitary tee on the horizontal, re-grade 3 inch drain at the end of the line in front of home, rest ok. | TAYLOR | TAYLOR | | PO= | P | 5253755 |