WOOD STONE CONSTRUCTION, LLC. | B= | C | 03/28/2017 | All other required Final inspections are complete. (This is a computer generated result) | BRIANB | BRIANB | | B= | C | 5458181 |
WOOD STONE CONSTRUCTION, LLC. | B= | P | 03/21/2017 | corrections okay. Additional Inspections Required (computer generated): External Agency Inspection HD= by HEALTHDEPT is not Completed yet. | BRIANB | BRIANB | | B= | P | 5451580 |
WOOD STONE CONSTRUCTION, LLC. | BFT | C | 03/21/2017 | observation letters on file | BRIANB | BRIANB | | BFT | C | 5451554 |
WOOD STONE CONSTRUCTION, LLC. | B= | P | 03/09/2017 | Temp CO: pending building final ( Expires: 4/8/2017 12:00:00 AM) | NELIDA | NELIDA | | B= | P | 5435702 |
WOOD STONE CONSTRUCTION, LLC. | BSP | P | 03/03/2017 | letter for interior pads on file | BERTW | BERTW | | BSP | P | 5430574 |
WOOD STONE CONSTRUCTION, LLC. | BSP | T | 03/03/2017 | PAID (REC#1406744) PLAN SPLICE FEE: $50 by: DANM for Construction: Remove finished basement from scope of work - Unfinished Basement - deck is framed only, not being completed at this time | DANM | DANM | | BSP | T | 5430522 |
WOOD STONE CONSTRUCTION, LLC. | B= | P | 03/02/2017 | need engineer observation letter to complete foundation footing inspection / final grade incomplete around home / missing ladder set up for inspection for attic / the front bedroom window (2040 single hung) installed is not per the approved design and does not meet the minimum emergency escape opening requirements (opening measures 21"x 21") / missing landing at the rear garage service door / rear deck is incomplete and missing all decking and guards - door to the rear deck is barricaded off / basement is unfinished - framed and insulated only / need to revise plans to reflect as built condition with unfinished basement / per the site rep - will update the approved design to reflect the as built condition with unfinished basement and no deck. Additional Inspections Required (computer generated): External Agency Inspection HD= by HEALTHDEPT is not Completed yet. / updated 3/9 met with Ken at office - changed inspection result from reject to partial | BRIANB | BRIANB | | B= | P | 5430045 |
WOOD STONE CONSTRUCTION, LLC. | BLA | C | 12/21/2016 | Item corrected | DAKOTAB | DAKOTAB | | BLA | C | 5373410 |
WOOD STONE CONSTRUCTION, LLC. | BLA | R | 12/05/2016 | missing electrical boxes at wire(s) through lath at doors and missing extensions for boxes at stucco pop-outs | BRIANB | BRIANB | | BLA | R | 5359911 |
WOOD STONE CONSTRUCTION, LLC. | BIN | P | 11/30/2016 | Complete BFR -- Insulation OK | DAKOTAB | DAKOTAB | | BIN | P | 5356712 |
WOOD STONE CONSTRUCTION, LLC. | BFR | P | 11/30/2016 | Need engineer observation letters to complete BFT -- Framing items corrected | DAKOTAB | DAKOTAB | | BFR | P | 5356705 |
WOOD STONE CONSTRUCTION, LLC. | BFR | R | 11/22/2016 | block garage door brackets / foam and firestop / strap trimmers at entry / strap plate breaks / strap lower stair landing ok to insulate | DALE | DALE | | BFR | R | 5351936 |
WOOD STONE CONSTRUCTION, LLC. | BFT | R | 11/15/2016 | need observation letter for interior pads and rear deck piers | BRIANB | BRIANB | | BFT | R | 5344661 |
WOOD STONE CONSTRUCTION, LLC. | BSP | P | 11/15/2016 | front and rear porch lid and posts okay / rear deck frame okay | BRIANB | BRIANB | | BSP | P | 5344645 |
WOOD STONE CONSTRUCTION, LLC. | BFI | C | 07/13/2016 | | DALE | DALE | | BFI | C | 5244025 |
WOOD STONE CONSTRUCTION, LLC. | BFD | C | 07/13/2016 | | DALE | DALE | | BFD | C | 5244018 |
WOOD STONE CONSTRUCTION, LLC. | BFN | C | 07/13/2016 | ok per eng. / all paperwork on file / float | DALE | DALE | | BFN | C | 5244015 |
WOOD STONE CONSTRUCTION, LLC. | BFT | P | 07/13/2016 | ok per eng. / interior pads not done per eng. | DALE | DALE | | BFT | P | 5244007 |
WOOD STONE CONSTRUCTION, LLC. | BFT | P | 06/07/2016 | AUTHORIZED INSPECTION BY ENGINEER | REBECCA | REBECCA | REBECCA | BFT | P | 5216678 |
WOOD STONE CONSTRUCTION, LLC. | BFN | P | 06/07/2016 | AUTHORIZED INSPECTION BY ENGINEER | REBECCA | REBECCA | REBECCA | BFN | P | 5216677 |
EMPIRE INCORPORATED | E= | C | 02/27/2017 | a/c pre-wire | MATTHEW | MATTHEW | | E= | C | 5426206 |
EMPIRE INCORPORATED | EP | C | 02/27/2017 | | MATTHEW | MATTHEW | | EP | C | 5426198 |
EMPIRE INCORPORATED | E= | P | 02/22/2017 | need gfi protection in garage , need light outside lower walk out , basement plugs on north wall need trimmed after sheetrock is hung | TOMC | TOMC | | E= | P | 5421727 |
EMPIRE INCORPORATED | ES | C | 11/29/2016 | Residential Underground: 200 amp sub-panel fed from pole mounted service------- no action needed | MATTHEW | MATTHEW | | ES | C | 5355159 |
EMPIRE INCORPORATED | ER | C | 11/29/2016 | completed 11-1-16 | MATTHEW | MATTHEW | | ER | C | 5355156 |
EMPIRE INCORPORATED | ES | R | 11/01/2016 | ground issue not corrected. | BRET | BRET | | ES | R | 5333383 |
EMPIRE INCORPORATED | ER | C | 11/01/2016 | | BRET | BRET | | ER | C | 5333381 |
EMPIRE INCORPORATED | ER | R | 10/24/2016 | Install and wire exhaust fans in bathrooms.-----------No more than 2 equipment grounding conductors per terminal. They should be the same size.-----------When you recall ask for service inspection too if ready.-----------Notes: Basement is frame but not wired.---------6/3 cu ----------No vac ---------UFER is not ir. | JOSEPH | JOSEPH | | ER | R | 5326588 |
D & J QUALITY ELECTRIC INC | EUG | C | 09/21/2016 | 4/0 with #4cu from pole to house | TOMC | TOMC | | EUG | C | 5298414 |
THE FURNACE GUY HEATING & COOLING | H= | C | 02/28/2017 | corrections made. note: unfinished basement, direct vent furnace, 6" outside air to return, a/c rough and line set, mantel ok. | PAULO | PAULO | | H= | C | 5427638 |
THE FURNACE GUY HEATING & COOLING | H= | P | 02/09/2017 | The vent was not mentioned at rough so i will need access to the attic for final. I also need the heater manufacturer's installation instructions on site. Wires are still on the B vent and require minimum 1" clearance from the vent. | MARK | MARK | | H= | P | 5411745 |
THE FURNACE GUY HEATING & COOLING | H= | P | 02/01/2017 | Garage heater vent required to be min 24" above upper roof. 115 and low volt on B vent, 1: minimum clearance required. Rest ok. Note: No mantle, no a/c condenser, has 6" outside air to the return. Un finished basement. | MARK | MARK | | H= | P | 5403847 |
THE FURNACE GUY HEATING & COOLING | HC | C | 11/07/2016 | RELEASE METER | LUKE | LUKE | | HC | C | 5337883 |
THE FURNACE GUY HEATING & COOLING | HRR | C | 11/07/2016 | CONTRACTOR SAYS BASEMENT WILL BE UNFINISHED BATH FANS NOT INSTALLED AT THIS TIME ONLY ONE BATHROOM HAS A VENT TO THE OUTDOORS ALL CORRECTIONS MADE.. | LUKE | LUKE | | HRR | C | 5337878 |
THE FURNACE GUY HEATING & COOLING | HRR | P | 11/01/2016 | Bath exhaust not complete in basement. Fireplace vent chase needs capped in attic or extend insulation shield to prevent insulation from contacting vent. Rest ok. Notes-- finished basement. Duct design. OSA to return. AC rough coil and line set. | JEFFL | JEFFL | | HRR | P | 5333100 |
J.J. BROOME PLUMBING AND HEATING LLC | HI | C | 10/21/2016 | 10# test ok. Notes-- 2'' main.. 1 fp.. 1 range.. 2 wh.. 1 furnace.. 1 garage heater.. 1 bbq.. 1'' to front of home.. | JEFFL | JEFFL | | HI | C | 5325347 |
J.J. BROOME PLUMBING AND HEATING LLC | HI | P | 10/19/2016 | Low test. Re inspect all. | JEFFL | JEFFL | | HI | P | 5322437 |
J.J. BROOME PLUMBING AND HEATING LLC | P= | C | 02/28/2017 | CORRECTIONS MADE , | GABE | GABE | | P= | C | 5427205 |
J.J. BROOME PLUMBING AND HEATING LLC | P= | P | 02/27/2017 | POTABLE WATER CERT TO SCANNING | GABE | GABE | | P= | P | 5425150 |
J.J. BROOME PLUMBING AND HEATING LLC | P= | P | 02/24/2017 | WATER REVERSED AT LAV BY KITCHEN , NEED POTABLE WATER CERT , REST OK . NOTE : UNFINISHED BASEMENT , TEMPERING IN BASEMENT BY DOOR , PVB INSTALLED , RECIRC INSTALLED | GABE | GABE | | P= | P | 5424555 |
J.J. BROOME PLUMBING AND HEATING LLC | PTO | C | 10/12/2016 | | TIM | TIM | | PTO | C | 5317184 |
WOOD STONE CONSTRUCTION, LLC. | PWO | C | 09/09/2016 | line from well to garage, need certificate of potable water by final | TED | TED | | PWO | C | 5289223 |
WOOD STONE CONSTRUCTION, LLC. | PWO | P | 08/17/2016 | line from main house to detached garage / cottage ok backflow by final | TIM | TIM | | PWO | P | 5271419 |
J.J. BROOME PLUMBING AND HEATING LLC | PB | C | 07/21/2016 | | TIM | TIM | | PB | C | 5250494 |