Z CRAFT CONSTRUCTION INC. | B= | C | 01/20/2017 | corrections okay | BRIANB | BRIANB | | B= | C | 5394386 |
Z CRAFT CONSTRUCTION INC. | B= | P | 01/18/2017 | missing all roof vents for ventilation / no deck installed -- Schedule a new Building Final when above items are complete. | BRIANB | BRIANB | | B= | P | 5392254 |
Z CRAFT CONSTRUCTION INC. | BLA | C | 10/31/2016 | At final, verify weep screed is 1/2" above all poured surfaces | DAKOTAB | DAKOTAB | | BLA | C | 5332111 |
Z CRAFT CONSTRUCTION INC. | BFR | C | 10/18/2016 | | BOBF | BOBF | | BFR | C | 5321865 |
Z CRAFT CONSTRUCTION INC. | BIN | C | 10/18/2016 | | BOBF | BOBF | | BIN | C | 5321864 |
Z CRAFT CONSTRUCTION INC. | BFR | P | 10/13/2016 | Missing roof jacks for HVAC vent in kitchen and laundry vent -- Missing anchor bolts within 12" of splice at master bath plumbing pipes and splice right of electrical panel in garage -- Plans calls for (2) HTS20's at bearing locations for girder in garage | DAKOTAB | DAKOTAB | | BFR | P | 5318212 |
Z CRAFT CONSTRUCTION INC. | BFR | R | 10/12/2016 | no plans in permit box or in home / call ahead number provided would not complete / called again onsite - no answer again at call ahead number provided / no inspection done | BRIANB | BRIANB | | BFR | R | 5317176 |
Z CRAFT CONSTRUCTION INC. | BIN | P | 10/11/2016 | Qualified third party energy inspection documentation must be presented at time of final building (B=) inspection | GITA | GITA | | BIN | P | 5315699 |
Z CRAFT CONSTRUCTION INC. | BSP | P | 09/27/2016 | Front porch post and lid OK -- Fire box framing OK | DAKOTAB | DAKOTAB | | BSP | P | 5304016 |
Z CRAFT CONSTRUCTION INC. | BSP | T | 09/26/2016 | PAID (REC#1364817) PLAN SPLICE FEE: $50 by: DANM for Construction: Add cantilevered fieplace | DANM | DANM | | BSP | T | 5302030 |
Z CRAFT CONSTRUCTION INC. | BFN | C | 07/21/2016 | foundation design and letter from Parr for foundation modification reinforcement received | BRIANB | BRIANB | | BFN | C | 5250536 |
Z CRAFT CONSTRUCTION INC. | BFI | C | 07/21/2016 | 2" R10 foam installed 32" deep okay | BRIANB | BRIANB | | BFI | C | 5250515 |
Z CRAFT CONSTRUCTION INC. | BFD | C | 07/21/2016 | drain installed habitable and to daylight at the north east corner / damp proof okay | BRIANB | BRIANB | | BFD | C | 5250511 |
Z CRAFT CONSTRUCTION INC. | BFN | P | 07/12/2016 | need clarification from engineer for details 6 and 7 on foundation design/ shows 3 #4 bars at top on drawing -- need clean copy of stamped foundation design -- rest of fndn ok -- eufer ok | SCOTTS | SCOTTS | | BFN | P | 5242877 |
Z CRAFT CONSTRUCTION INC. | BFT | C | 07/08/2016 | soils report/open ex on file --- 5000 psf -- 10% -- provide foundation design at BFN | SCOTTS | SCOTTS | | BFT | C | 5240904 |
DUKES ELECTRIC, INC | E= | C | 12/19/2016 | | BRET | BRET | | E= | C | 5371722 |
DUKES ELECTRIC, INC | EUG | C | 10/13/2016 | #2al service lateral from pole to home | MATTHEW | MATTHEW | | EUG | C | 5318196 |
DUKES ELECTRIC, INC | ES | C | 10/13/2016 | Residential Overhead: 100 amp 3/w: new res------ meter is set; need seal | MATTHEW | MATTHEW | | ES | C | 5318193 |
DUKES ELECTRIC, INC | ER | C | 09/30/2016 | slab on grade, non-ir ufer (in laundry room), no vac, no mcc's, #6al to range | MATTHEW | MATTHEW | | ER | C | 5307884 |
MILLER HEATING & AIR CONDITIONING, INC. | H= | C | 01/10/2017 | R/A VERIFIED. | LIDO | LIDO | | H= | C | 5385039 |
MILLER HEATING & AIR CONDITIONING, INC. | H= | P | 01/09/2017 | NEED DOORS INSTALLED TO VERIFIE 1" MINIMUM UNDERCUT FOR R/A PATH . NOTES: HI LOW GRILLS TO MECHANICAL ROOM FOR COMBUSTION AIR, slab on grade. Duct design. No AC. | LIDO | LIDO | | H= | P | 5384962 |
MILLER HEATING & AIR CONDITIONING, INC. | HC | C | 10/11/2016 | RELEASE METER | JEFFL | JEFFL | | HC | C | 5315578 |
MILLER HEATING & AIR CONDITIONING, INC. | HRR | C | 10/11/2016 | | JEFFL | JEFFL | | HRR | C | 5315568 |
MILLER HEATING & AIR CONDITIONING, INC. | HRR | P | 10/07/2016 | Unable to inspect vent above lid in mech room. Please provide ladder for re inspection. Rest ok. Notes-- slab on grade. Duct design. No AC. | JEFFL | JEFFL | | HRR | P | 5313501 |
ROCKY MOUNTAIN RADIANT HEATING & PLUMBING, INC. | HI | C | 10/04/2016 | 10 LB GAS TEST GOOD 1 1/4'' MAIN FURNACE WATER HEATER RANGE FIREPLACE DRYER.. | LUKE | LUKE | | HI | C | 5310060 |
ROCKY MOUNTAIN RADIANT HEATING & PLUMBING, INC. | P= | C | 12/30/2016 | NOTE : SLAB ON GRADE , NO IRRIGATION , POTABLE WATER CERT TO SCANNING | GABE | GABE | | P= | C | 5380205 |
HOMEOWNER | PWO | C | 12/14/2016 | | TIM | TIM | | PWO | C | 5367706 |
ROCKY MOUNTAIN RADIANT HEATING & PLUMBING, INC. | PTO | C | 10/03/2016 | slab on grade | TED | TED | | PTO | C | 5308635 |
ROCKY MOUNTAIN RADIANT HEATING & PLUMBING, INC. | PB | C | 07/27/2016 | | TIM | TIM | | PB | C | 5255480 |